XWXingzhu Wang

Xingzhu Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xingzhu Wang has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Novel Markov Model for Protective Relay Reliability

    by Xingzhu Wang, Yongxin Chen, Minghao Wen, Xianggen Yin

    Microprocessor-based protective relay has risen to the ‘technology of choice’ with regard to power system protection due to its monitoring capability, self-checking capability, event recording capability, communication capability, capability for remote interrogation and setting application, and multiple setting groups. However, the existing Markov reliability model for protective relays does not reflect the state of the art of microprocessor-based relays. And the complexity of the Markov model limits its application in the wide range of relay studies. Therefore, this article establishes the general state-transition diagrams of protected components and relays, and a novel Markov model of a protection/component system by taking account of monitoring, self-checking, routine tests, common-cause failures, human error, operation of back-up protection, relay failure to operations and relay mal-trips. The study results of the sensitivity analysis and comparison analysis demonstrate the rationality and superiority of the novel model.


  • Open Access

    A Novel Protection Scheme for Outgoing Line Fault of AC Transmission Line near the Inverter Station of AC/DC Hybrid Power Grid based on AC Filter Characteristics

    by Lin Yang, Minghao Wen, Yu Chen, Xingzhu Wang

    Compared with traditional AC power grid, the fault characteristics of the AC/DC hybrid power grid are more complex and variable. Hence there is a problem of incorrect action for the fault detection elements used in traditional AC power grid which comes up when an outgoing line fault occurs on the AC transmission line in the vicinity of the inverter station. To distinguish the fault direction under the aforementioned situation, a directional protection scheme based on the characteristics of the AC filter is proposed in this paper. Considering the information can be measured by AC line relay, a method for estimating the current provided by the AC filter is given during an outgoing line fault. According to the difference of current characteristics between forward and reverse fault, the fault direction can be judged based on waveform similarity among the currents provided by the AC filter and measured by the AC line relay. Finally, a simulation model is built on the PSCAD/EMTDC platform for extensive performance evaluation. The reliability and effectiveness of the protection scheme are verified under different cases.