Juliana Anany Gonzales Guarneri
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Juliana Anany Gonzales Guarneri has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Richard Bengt Price
Department of Dental Clinical Sciences, Faculty of Dentistry, Dalhousie University, Halifax, NS B3H 4R2, Canada
10 shared publications - Cesar Augusto Galvão Arrais
Department of Restorative Dentistry State University of Ponta Grossa Ponta Grossa Brazil
6 shared publications - Cristiane Maucoski
Department of Dental Clinical Sciences, Dalhousie University, Faculty of Dentistry, Halifax, Nova Scotia, Canada
6 shared publications - Brett Daniel MacNeil
Department of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada
4 shared publications - Alexandre Gareau
Department of Dental Clinical Sciences, Dalhousie University, 5981 University Avenue, Halifax, Nova Scotia, B3H 4R2, Canada
3 shared publications - Daniel Labrie
Department of Physics and Atmospheric Science, Dalhousie University, Halifax, NS B3H 4R2, Canada
2 shared publications
Latest Publications
- Open Access
- 15 April 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 172, 106701
Do all multi-peak LED light-curing units emit similar light outputs?
- 15 April 2026
- Published by Elsevier in Journal of Dentistry
- Vol. 172, 106701
Open AccessDo all multi-peak LED light-curing units emit similar light outputs?
- Open Access
- 19 February 2026
- Published by Springer Nature in Odontology
- Vol. 114 (4) , 2614-2625
In vitro assessment of the role of air spray on pulp temperature changes for preheated resin composite Class V restorations in lower incisor
To evaluate the effect of 15- and 30-psi air spray on in vitro pulp temperature (PT) during light-curing of buccal Class V restorations in lower incisors using preheated resin composites (RBCs). After ethical approval, a Class V cavity was prepared in a sound lower central incisor. A T-type thermocouple was inserted into the pulp chamber and connected to a temperature measurement system (Thermes WiFi, Physitemp). Simulated pulpal fluid flow was maintained at a rate of 0.001 mL/min. Real-time PT and working time were recorded during restoration with Viscalor Bulk-fill (VOCO) and Filtek One Bulk-fill (Solventum) preheated to 68 °C. Air spray (15 or 30 psi) was directed to the lingual surface, starting 3 s before and maintained throughout light-curing ( n = 9). Vickers hardness (VHN) was measured at the middle and inner surfaces near the top and bottom of each specimen. PT and VHN data were analyzed using nonparametric mixed ANOVA, and working time was analyzed using nonparametric two-way ANOVA, both followed by Bonferroni’s post hoc tests ( α = 0.05). Light-curing of preheated RBCs significantly increased PT (42.5 ± 1.3 °C; p < 0.001). Air spray at 15 and 30 psi reduced PT values (28.4 ± 1.3 °C and 26.8 ± 1.8 °C, respectively; p < 0.001) without affecting VHN values. Air spray during light-curing effectively minimized pulp temperature rise during restorative procedures using preheated RBCs on lower incisors.
- 19 February 2026
- Published by Springer Nature in Odontology
- Vol. 114 (4) , 2614-2625
Open AccessIn vitro assessment of the role of air spray on pulp temperature changes for preheated resin composite Class V restorations in lower incisor
To evaluate the effect of 15- and 30-psi air spray on in vitro pulp temperature (PT) during light-curing of buccal Class V restorations in lower incisors using preheated resin composites (RBCs). After ethical approval, a Class V cavity was prepared in a sound lower central incisor. A T-type thermocouple was inserted into the pulp chamber and connected to a temperature measurement system (Thermes WiFi, Physitemp). Simulated pulpal fluid flow was maintained at a rate of 0.001 mL/min. Real-time PT and working time were recorded during restoration with Viscalor Bulk-fill (VOCO) and Filtek One Bulk-fill (Solventum) preheated to 68 °C. Air spray (15 or 30 psi) was directed to the lingual surface, starting 3 s before and maintained throughout light-curing ( n = 9). Vickers hardness (VHN) was measured at the middle and inner surfaces near the top and bottom of each specimen. PT and VHN data were analyzed using nonparametric mixed ANOVA, and working time was analyzed using nonparametric two-way ANOVA, both followed by Bonferroni’s post hoc tests ( α = 0.05). Light-curing of preheated RBCs significantly increased PT (42.5 ± 1.3 °C; p < 0.001). Air spray at 15 and 30 psi reduced PT values (28.4 ± 1.3 °C and 26.8 ± 1.8 °C, respectively; p < 0.001) without affecting VHN values. Air spray during light-curing effectively minimized pulp temperature rise during restorative procedures using preheated RBCs on lower incisors.
- Open Access
- 25 September 2025
- Published by Elsevier in Dental Materials
- Vol. 42 (1) , 41-51
Comparison between the dual-exponential and autocatalytic models to examine rapid photopolymerization kinetics of dental resins
- 25 September 2025
- Published by Elsevier in Dental Materials
- Vol. 42 (1) , 41-51
Open AccessComparison between the dual-exponential and autocatalytic models to examine rapid photopolymerization kinetics of dental resins
- Open Access
- 24 August 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (12) , 2568-2578
Effect of Moving the Tip of the Light Curing Unit on the Irradiance Value Delivered
Objective: To determine the effect of differences in the distances and radial positions of the tips of Light‐Curing Units (LCU) on the irradiance values delivered. Materials and Methods: Four LCUs —Valo X, Emitter A, CuringPen , and Pinkwave were tested at different distances from the tip (0, 2, 4, 6, 8 mm) and radial displacements (2 and 4 mm East, West, North, South). The radiant power ( mW ) and emission spectrum ( mW /nm) were measured using an integrating sphere with a 4 mm aperture. Calibrated irradiance beam profiles were recorded across the tip using a laser beam analyzer. Data were analyzed with a two‐way ANOVA at a significance level of 5%. Results: Radial displacement significantly reduced the irradiance values delivered from all four LCUs ( p < 0.05). At 4 mm, the mean irradiance value was below 1000 mW /cm 2 for Emitter A (256 mW/cm 2 ), CuringPen (573 mW/cm 2 ), and Valo X (955 mW/cm 2 ), but not for the Pinkwave (1157 mW /cm 2 ). At the 2 and 4 mm distance from the tip, the Valo X delivered consistent mean irradiance values at both the center and radial positions (2 mm: 1120 mW /cm 2 and 1089 mW /cm 2 ; 4 mm: 979 mW /cm 2 and 945 mW /cm 2 , p > 0.05). The Valo X emitted the most homogeneous beam profile, irrespective of the distance. Conclusion: Variations of 2 or 4 mm in the radial tip position negatively affected irradiance values from the LCUs tested. Clinical Significance: The radial position and LCU choice can significantly affect the irradiance delivered.
- 24 August 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (12) , 2568-2578
Open AccessEffect of Moving the Tip of the Light Curing Unit on the Irradiance Value Delivered
Objective: To determine the effect of differences in the distances and radial positions of the tips of Light‐Curing Units (LCU) on the irradiance values delivered. Materials and Methods: Four LCUs —Valo X, Emitter A, CuringPen , and Pinkwave were tested at different distances from the tip (0, 2, 4, 6, 8 mm) and radial displacements (2 and 4 mm East, West, North, South). The radiant power ( mW ) and emission spectrum ( mW /nm) were measured using an integrating sphere with a 4 mm aperture. Calibrated irradiance beam profiles were recorded across the tip using a laser beam analyzer. Data were analyzed with a two‐way ANOVA at a significance level of 5%. Results: Radial displacement significantly reduced the irradiance values delivered from all four LCUs ( p < 0.05). At 4 mm, the mean irradiance value was below 1000 mW /cm 2 for Emitter A (256 mW/cm 2 ), CuringPen (573 mW/cm 2 ), and Valo X (955 mW/cm 2 ), but not for the Pinkwave (1157 mW /cm 2 ). At the 2 and 4 mm distance from the tip, the Valo X delivered consistent mean irradiance values at both the center and radial positions (2 mm: 1120 mW /cm 2 and 1089 mW /cm 2 ; 4 mm: 979 mW /cm 2 and 945 mW /cm 2 , p > 0.05). The Valo X emitted the most homogeneous beam profile, irrespective of the distance. Conclusion: Variations of 2 or 4 mm in the radial tip position negatively affected irradiance values from the LCUs tested. Clinical Significance: The radial position and LCU choice can significantly affect the irradiance delivered.
- Open Access
- 28 July 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 162, 105990
Impact of high irradiance and short exposure times on the polymerization kinetics of sculptable and flowable bulk-fill composites
- 28 July 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 162, 105990
Open AccessImpact of high irradiance and short exposure times on the polymerization kinetics of sculptable and flowable bulk-fill composites
- Open Access
- 28 May 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 160, 105859
Influence of temperature and primer application on setting time and degree of conversion of a dual-cure self-adhesive cement
- 28 May 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 160, 105859
Open AccessInfluence of temperature and primer application on setting time and degree of conversion of a dual-cure self-adhesive cement
- Open Access
- 17 March 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (7) , 1802-1813
Effect of Three Heating Guns on the Temperature of Two Bulk‐Fill Resin‐Based Composites
Objective: To evaluate the effect of three heating guns—Phasor (Vista Apex, Racine, USA), VisCalor (VOCO, Cuxhaven, Germany), and Compex HD (AdDent Inc. Danbury, USA)—on the temperature changes of two bulk‐fill resin‐based composites (RBCs): VisCalor Bulk (VBF, VOCO) and Filtek One Bulk Fill Restorative (OBF, Solventum, St. Paul, USA).Materials and Methods: Temperature changes were measured using a thermal camera (PI 640i, Optris Infrared Measurements, Berlin, Germany) during insertion and photocuring in a simulated proximal box of a Class II cavity and within the RBC capsules during heating. The RBCs were photocured using the Bluephase PowerCure (Ivoclar, Schaan, Liechtenstein) for 20s. Data were analyzed using repeated measures ANOVA and Tukey's test for each RBC (α = 0.05). The temperature of the RBCs at the same depth were analyzed by t‐test (α = 0.05).Results: OBF heated with Compex produced the lowest temperature rise at the pulpal floor (2.7°C ± 0.4°C), while VBF heated with Phasor produced the highest (8.8°C ± 2.4°C). The greatest temperature increases were at the top of the restoration. OBF heated with Phasor reached 48.6°C ± 4.7°C. The Phasor and VisCalor produced two temperature peaks in the RBC inside the capsule, while the Compex maintained a steady peak temperature.Conclusion: The heating gun and RBC produced different temperatures when heating, inserting, and light‐activation of the RBCs.Clinical Significance: The choice of RBC and heating gun can substantially affect the temperature of the RBC and influence its handling properties.
- 17 March 2025
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
- Vol. 37 (7) , 1802-1813
Open AccessEffect of Three Heating Guns on the Temperature of Two Bulk‐Fill Resin‐Based Composites
Objective: To evaluate the effect of three heating guns—Phasor (Vista Apex, Racine, USA), VisCalor (VOCO, Cuxhaven, Germany), and Compex HD (AdDent Inc. Danbury, USA)—on the temperature changes of two bulk‐fill resin‐based composites (RBCs): VisCalor Bulk (VBF, VOCO) and Filtek One Bulk Fill Restorative (OBF, Solventum, St. Paul, USA).Materials and Methods: Temperature changes were measured using a thermal camera (PI 640i, Optris Infrared Measurements, Berlin, Germany) during insertion and photocuring in a simulated proximal box of a Class II cavity and within the RBC capsules during heating. The RBCs were photocured using the Bluephase PowerCure (Ivoclar, Schaan, Liechtenstein) for 20s. Data were analyzed using repeated measures ANOVA and Tukey's test for each RBC (α = 0.05). The temperature of the RBCs at the same depth were analyzed by t‐test (α = 0.05).Results: OBF heated with Compex produced the lowest temperature rise at the pulpal floor (2.7°C ± 0.4°C), while VBF heated with Phasor produced the highest (8.8°C ± 2.4°C). The greatest temperature increases were at the top of the restoration. OBF heated with Phasor reached 48.6°C ± 4.7°C. The Phasor and VisCalor produced two temperature peaks in the RBC inside the capsule, while the Compex maintained a steady peak temperature.Conclusion: The heating gun and RBC produced different temperatures when heating, inserting, and light‐activation of the RBCs.Clinical Significance: The choice of RBC and heating gun can substantially affect the temperature of the RBC and influence its handling properties.
- Open Access
- 28 February 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (5) , 503-512
Evaluation of a quadwave curing light compared to a dual-peak LED curing light
- 28 February 2025
- Published by Elsevier in Dental Materials
- Vol. 41 (5) , 503-512
Open AccessEvaluation of a quadwave curing light compared to a dual-peak LED curing light
- Open Access
- 6 November 2024
- Published by Elsevier in Dental Materials
- Vol. 41 (1) , 42-50
Ability of a novel primer to enhance the polymerization of a self-cured resin composite
- 6 November 2024
- Published by Elsevier in Dental Materials
- Vol. 41 (1) , 42-50
Open AccessAbility of a novel primer to enhance the polymerization of a self-cured resin composite
- Open Access
- 26 September 2024
- Published by Elsevier in Journal of Dentistry
- Vol. 150, 105375
The dark art of light curing in dentistry
- 26 September 2024
- Published by Elsevier in Journal of Dentistry
- Vol. 150, 105375
Open AccessThe dark art of light curing in dentistry