Michael Blankstein
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Michael Blankstein has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Nathaniel J. Nelms
Department of Orthopaedics and Rehabilitation, University of Vermont, Burlington, Vermont
4 shared publications - Mark A. Haimes
Department of Orthopaedics and Rehabilitation, University of Vermont, Burlington, Vermont
2 shared publications - Patrick C. Schottel
University of Vermont Medical Center, Burlington, Vermont
2 shared publications - Alastair Stephens
Department of Trauma and Orthopaedics, University Hospital Coventry, Coventry, United Kingdom; and
1 shared publication Ali MBChB Ridha
Department of Trauma and Orthopaedics, University Hospital Coventry, Coventry, United Kingdom; and
1 shared publication- Bradley M. Anair
Department of Medicine, College of Medicine, University of Vermont, Burlington, Vermont
1 shared publication
Latest Publications
- Open Access
- 1 July 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (3)
Effect of Femoral Component Flexion in Robotic-Assisted Total Knee Arthroplasty on Retrograde Intramedullary Nail Sagittal Trajectory Angulation
Background: In robotic-assisted total knee arthroplasty (RA-TKA), the femoral prosthesis is positioned independent of the intramedullary canal and frequently in flexion for function optimization. Femoral prosthesis flexion displaces retrograde intramedullary nail (rIMN) start point posteriorly potentially exacerbating hyperextension deformity in periprosthetic fracture (PPFx) fixation. The aim of this study was to determine the relationship between RA-TKA femoral component flexion with rIMN sagittal trajectory angulation. We hypothesized flexion of the femoral component increases nail sagittal angle. Methods: This is a single-center academic observational study including adult patients undergoing primary RA-TKA by 3 fellowship-trained arthroplasty surgeons between August 2023 and February 2024. Final femoral implant characteristics after knee gap balancing were obtained from intraoperative computerized tomography screenshots. Sagittal angle measurements of rIMN trajectory based on distal femoral nail start point and center of femoral shaft were measured using ImageJ software and compared with several variables with a focus on femoral component flexion for 10-mm and 12-mm nail sizes. Results: A total of 111 patients (61 female and 50 male) with a mean age of 67 years (SD 10) and height 168 cm (SD 11) were included. The mean femoral component flexion was 5.87° (SD 2.13), and the mean nail sagittal trajectory angle was 9.83° (SD 2.79) and 11.43° (SD 2.88) for the 10-mm and 12-mm nails, respectively. There was a significant linear correlation of a 0.50° increase in the mean sagittal angle for every 1.0° increase in femoral component flexion for both nail sizes (p < 0.001). Conclusions: There is a linear correlation between femoral component flexion and rIMN sagittal trajectory angle. The mean sagittal angulation was approximately 10°, and the mean component flexion was 6°. As number of RA-TKAs performed nationally is expected to increase, a rIMN with a distal bend designed to compensate for femoral component flexion could be considered to limit hyperextension deformity in distal femur PPFx fixation. Level of Evidence: Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 1 July 2025
- Published by Wolters Kluwer Health in JBJS Open Access
- Vol. 10 (3)
Open AccessEffect of Femoral Component Flexion in Robotic-Assisted Total Knee Arthroplasty on Retrograde Intramedullary Nail Sagittal Trajectory Angulation
Background: In robotic-assisted total knee arthroplasty (RA-TKA), the femoral prosthesis is positioned independent of the intramedullary canal and frequently in flexion for function optimization. Femoral prosthesis flexion displaces retrograde intramedullary nail (rIMN) start point posteriorly potentially exacerbating hyperextension deformity in periprosthetic fracture (PPFx) fixation. The aim of this study was to determine the relationship between RA-TKA femoral component flexion with rIMN sagittal trajectory angulation. We hypothesized flexion of the femoral component increases nail sagittal angle. Methods: This is a single-center academic observational study including adult patients undergoing primary RA-TKA by 3 fellowship-trained arthroplasty surgeons between August 2023 and February 2024. Final femoral implant characteristics after knee gap balancing were obtained from intraoperative computerized tomography screenshots. Sagittal angle measurements of rIMN trajectory based on distal femoral nail start point and center of femoral shaft were measured using ImageJ software and compared with several variables with a focus on femoral component flexion for 10-mm and 12-mm nail sizes. Results: A total of 111 patients (61 female and 50 male) with a mean age of 67 years (SD 10) and height 168 cm (SD 11) were included. The mean femoral component flexion was 5.87° (SD 2.13), and the mean nail sagittal trajectory angle was 9.83° (SD 2.79) and 11.43° (SD 2.88) for the 10-mm and 12-mm nails, respectively. There was a significant linear correlation of a 0.50° increase in the mean sagittal angle for every 1.0° increase in femoral component flexion for both nail sizes (p < 0.001). Conclusions: There is a linear correlation between femoral component flexion and rIMN sagittal trajectory angle. The mean sagittal angulation was approximately 10°, and the mean component flexion was 6°. As number of RA-TKAs performed nationally is expected to increase, a rIMN with a distal bend designed to compensate for femoral component flexion could be considered to limit hyperextension deformity in distal femur PPFx fixation. Level of Evidence: Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 1 January 2025
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 39 (1) , 14-21
Shall We Not Pressurize It? Effects of Bone Cement Pressurization on Mortality and Revision After Hip Hemiarthroplasty for Neck of Femur Fracture Patients: A Comparative Cohort Study
OBJECTIVES: This study aimed to compare 30-day postoperative mortality, and revision for aseptic femoral component loosening and all-causes after hip hemiarthroplasty, performed with or without pressurization of the bone cement, in patients with neck of femur fracture. METHODS: Design: Retrospective cohort study. Setting: Level I trauma center Patient Selection Criteria: Patients ≥60 years with OTA/AO 31B who underwent a cemented hip hemiarthroplasty from December 10, 2007 (database inception) to November 15, 2023 (search date) were reviewed. Outcome Measures and Comparisons: Comparisons were made between patients who underwent hip hemiarthroplasty with versus without pressurization of the bone cement for outcomes 30-day postoperative mortality, revision for aseptic femoral component loosening, and revision for all-causes. RESULTS: There were 406 procedures among 402 patients, and 722 procedures among 713 patients that were performed with and without pressurization of the bone cement, respectively. Mean ages were 83.1 and 84.3 years (P = 0.018), with 72.2% and 68.6% (P = 0.205) women in the pressurized and non-pressurized cement patient groups, respectively. There were no differences in 30-day postoperative mortality (7.2% vs. 8.2%; HR 0.89, 95% CI 0.46–1.73, P = 0.727). There were no differences in all-cause revision (HR 1.04, 95% CI 0.27–4.04, P = 0.953). No revisions were performed for aseptic loosening. Survival at 10 years postoperatively was 15.3% (95% CI 11.46–19.64) and 12.6% (95% CI 7.67–18.82) among patients who underwent hemiarthroplasty with and without bone cement pressurization, respectively. CONCLUSIONS: There were no differences in 30-day postoperative mortality among patients who underwent hemiarthroplasty with, compared to, without bone cement pressurization. Bone cement pressurization did not confer any advantages for revision outcomes that may be attributed, in part, to patients' high mortality rate and low survival beyond 10 years postoperatively. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 January 2025
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 39 (1) , 14-21
Shall We Not Pressurize It? Effects of Bone Cement Pressurization on Mortality and Revision After Hip Hemiarthroplasty for Neck of Femur Fracture Patients: A Comparative Cohort Study
OBJECTIVES: This study aimed to compare 30-day postoperative mortality, and revision for aseptic femoral component loosening and all-causes after hip hemiarthroplasty, performed with or without pressurization of the bone cement, in patients with neck of femur fracture. METHODS: Design: Retrospective cohort study. Setting: Level I trauma center Patient Selection Criteria: Patients ≥60 years with OTA/AO 31B who underwent a cemented hip hemiarthroplasty from December 10, 2007 (database inception) to November 15, 2023 (search date) were reviewed. Outcome Measures and Comparisons: Comparisons were made between patients who underwent hip hemiarthroplasty with versus without pressurization of the bone cement for outcomes 30-day postoperative mortality, revision for aseptic femoral component loosening, and revision for all-causes. RESULTS: There were 406 procedures among 402 patients, and 722 procedures among 713 patients that were performed with and without pressurization of the bone cement, respectively. Mean ages were 83.1 and 84.3 years (P = 0.018), with 72.2% and 68.6% (P = 0.205) women in the pressurized and non-pressurized cement patient groups, respectively. There were no differences in 30-day postoperative mortality (7.2% vs. 8.2%; HR 0.89, 95% CI 0.46–1.73, P = 0.727). There were no differences in all-cause revision (HR 1.04, 95% CI 0.27–4.04, P = 0.953). No revisions were performed for aseptic loosening. Survival at 10 years postoperatively was 15.3% (95% CI 11.46–19.64) and 12.6% (95% CI 7.67–18.82) among patients who underwent hemiarthroplasty with and without bone cement pressurization, respectively. CONCLUSIONS: There were no differences in 30-day postoperative mortality among patients who underwent hemiarthroplasty with, compared to, without bone cement pressurization. Bone cement pressurization did not confer any advantages for revision outcomes that may be attributed, in part, to patients' high mortality rate and low survival beyond 10 years postoperatively. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 1 September 2022
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 133 (3) , 647-660
Effects of total knee arthroplasty on skeletal muscle structure and function at the cellular, organellar, and molecular levels
We report the first evaluation of the effects of total knee arthroplasty (TKA) on skeletal muscle at the cellular and subcellular levels. We found marked effects of TKA to cause skeletal muscle fiber atrophy and contractile dysfunction in older adults, as well as molecular mechanisms underlying impaired contractility. Our results reveal profound effects of TKA on muscle fiber size and intrinsic contractility early after surgery that may contribute to functional disability.
- 1 September 2022
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 133 (3) , 647-660
Open AccessEffects of total knee arthroplasty on skeletal muscle structure and function at the cellular, organellar, and molecular levels
We report the first evaluation of the effects of total knee arthroplasty (TKA) on skeletal muscle at the cellular and subcellular levels. We found marked effects of TKA to cause skeletal muscle fiber atrophy and contractile dysfunction in older adults, as well as molecular mechanisms underlying impaired contractility. Our results reveal profound effects of TKA on muscle fiber size and intrinsic contractility early after surgery that may contribute to functional disability.
- 11 August 2022
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 30 (20) , e1279-e1290
Selecting a Press-fit Stem for Total Hip Arthroplasty: The Rationale and Evolution of the Modern Femoral Prosthesis
Noncemented press-fit femoral stems predominate in total hip arthroplasty for all age groups with generally excellent long-term survivorship. The 2021 American Joint Replacement Registry reports that 96% of all elective primary total hip arthroplasties used noncemented femoral implant fixation. 1 Today, there are many styles of press-fit stems, each with supposed benefits, based on a range of design philosophies. Design aspects to consider when selecting a stem are numerous, including stem geometry, stem length, collared or collarless, material properties, and surface structure. Although most stem designs demonstrate excellent results, the differences in stem designs are intimately linked to additional factors such as ease of use/implantation, percentage of surface osseointegration, overall bone removal versus bone stock preservation, subsequent femoral stress shielding, and consideration of complexity of later revision. A surgeon with a broad understanding and appreciation of femoral stem designs should be prepared to select between the multitude of options to best serve individual patients.
- 11 August 2022
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 30 (20) , e1279-e1290
Selecting a Press-fit Stem for Total Hip Arthroplasty: The Rationale and Evolution of the Modern Femoral Prosthesis
Noncemented press-fit femoral stems predominate in total hip arthroplasty for all age groups with generally excellent long-term survivorship. The 2021 American Joint Replacement Registry reports that 96% of all elective primary total hip arthroplasties used noncemented femoral implant fixation. 1 Today, there are many styles of press-fit stems, each with supposed benefits, based on a range of design philosophies. Design aspects to consider when selecting a stem are numerous, including stem geometry, stem length, collared or collarless, material properties, and surface structure. Although most stem designs demonstrate excellent results, the differences in stem designs are intimately linked to additional factors such as ease of use/implantation, percentage of surface osseointegration, overall bone removal versus bone stock preservation, subsequent femoral stress shielding, and consideration of complexity of later revision. A surgeon with a broad understanding and appreciation of femoral stem designs should be prepared to select between the multitude of options to best serve individual patients.
- 10 May 2021
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 36 (1) , e12-e17
A Novel Fluoroscopic Method for Assessing Rotational Malalignment of the Tibia
Objective: To evaluate the accuracy and reliability of a novel fluoroscopic technique for assessing tibial rotation and compare it with a previously described fluoroscopic method. Methods: A multiplanar circular ring external fixator was secured to the tibial diaphysis of 5 cadaveric lower extremity specimens. Using deformity correction software, the frame and tibia were programed to randomly rotate 5, 10, 15, 20, 25, and 30 degrees of internal and external rotation. After each rotation, 2 blinded, independent observers measured the degree of tibial rotation using 2 different fluoroscopic methods: the previously described “mortise” method and the novel “intermalleolar” method. A total of 65 measurements were made by each observer. Accuracy and interobserver reliability were calculated. Results: Both intermalleolar and mortise methods had a mean absolute rotational difference from the true torsion of 3 degrees (standard error 1; range, 0–10 degrees intermalleolar vs. 0–18 degrees mortise). We found that 98.5% (128/130) of measurements using the intermalleolar method were less than 10 degrees from the true rotation compared with 93.8% (122/130) using the mortise method. Both the intermalleolar and the mortise methods had excellent interobserver reliability (intraclass correlation coefficient 0.99 and 0.96, respectively). Conclusion: Measuring tibial rotation fluoroscopically using the intermalleolar method is both accurate and reliable. Compared with the previously described mortise method, it has similar accuracy and provides a value that approximates the true tibial rotation. Also, it can be used reliably and effectively intraoperatively to identify tibial malrotation and assist in intraoperative rotational corrections.
- 10 May 2021
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 36 (1) , e12-e17
A Novel Fluoroscopic Method for Assessing Rotational Malalignment of the Tibia
Objective: To evaluate the accuracy and reliability of a novel fluoroscopic technique for assessing tibial rotation and compare it with a previously described fluoroscopic method. Methods: A multiplanar circular ring external fixator was secured to the tibial diaphysis of 5 cadaveric lower extremity specimens. Using deformity correction software, the frame and tibia were programed to randomly rotate 5, 10, 15, 20, 25, and 30 degrees of internal and external rotation. After each rotation, 2 blinded, independent observers measured the degree of tibial rotation using 2 different fluoroscopic methods: the previously described “mortise” method and the novel “intermalleolar” method. A total of 65 measurements were made by each observer. Accuracy and interobserver reliability were calculated. Results: Both intermalleolar and mortise methods had a mean absolute rotational difference from the true torsion of 3 degrees (standard error 1; range, 0–10 degrees intermalleolar vs. 0–18 degrees mortise). We found that 98.5% (128/130) of measurements using the intermalleolar method were less than 10 degrees from the true rotation compared with 93.8% (122/130) using the mortise method. Both the intermalleolar and the mortise methods had excellent interobserver reliability (intraclass correlation coefficient 0.99 and 0.96, respectively). Conclusion: Measuring tibial rotation fluoroscopically using the intermalleolar method is both accurate and reliable. Compared with the previously described mortise method, it has similar accuracy and provides a value that approximates the true tibial rotation. Also, it can be used reliably and effectively intraoperatively to identify tibial malrotation and assist in intraoperative rotational corrections.
- 19 February 2020
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 28 (14) , e586-e594
The Use of Cement in Hip Arthroplasty: A Contemporary Perspective
Notable advances in hip arthroplasty implants and techniques over the past 60 years have yielded excellent survivorship of fully cemented, hybrid, and reverse hybrid total hip replacements as demonstrated in joint registries worldwide. Major advances in noncemented implants have reduced the use of cement, particularly in North America. Noncemented implants predominate today based on procedural efficiency, concern related to thromboembolic risk, and a historic belief that cement was the primary cause of osteolysis and implant loosening. With the decline of cemented techniques, press-fit fixation has become common even in osteoporotic elderly patients. Unfortunately, there is a troubling rise in intraoperative, as well as early and late postoperative periprosthetic fractures associated with the use of noncemented implants. Despite the success of noncemented fixation, an understanding of modern cement techniques and cemented implant designs is useful to mitigate the risk of periprosthetic fractures. Cemented acetabular components can be considered in elderly patients with osteoporotic or pathologic bone. Cemented stems should be considered with abnormal proximal femoral morphology, conversion of failed hip fixation, inflammatory arthritis, patient age over 75 (especially women), osteoporotic bone (Dorr C), and in the treatment of femoral neck fractures.
- 19 February 2020
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 28 (14) , e586-e594
The Use of Cement in Hip Arthroplasty: A Contemporary Perspective
Notable advances in hip arthroplasty implants and techniques over the past 60 years have yielded excellent survivorship of fully cemented, hybrid, and reverse hybrid total hip replacements as demonstrated in joint registries worldwide. Major advances in noncemented implants have reduced the use of cement, particularly in North America. Noncemented implants predominate today based on procedural efficiency, concern related to thromboembolic risk, and a historic belief that cement was the primary cause of osteolysis and implant loosening. With the decline of cemented techniques, press-fit fixation has become common even in osteoporotic elderly patients. Unfortunately, there is a troubling rise in intraoperative, as well as early and late postoperative periprosthetic fractures associated with the use of noncemented implants. Despite the success of noncemented fixation, an understanding of modern cement techniques and cemented implant designs is useful to mitigate the risk of periprosthetic fractures. Cemented acetabular components can be considered in elderly patients with osteoporotic or pathologic bone. Cemented stems should be considered with abnormal proximal femoral morphology, conversion of failed hip fixation, inflammatory arthritis, patient age over 75 (especially women), osteoporotic bone (Dorr C), and in the treatment of femoral neck fractures.
- 28 July 2019
- Published by Springer Nature
- p. 169-187
Acetabular and Femoral Neck Fracture Nonunion and Malunion
- 28 July 2019
- Published by Springer Nature
- p. 169-187
Acetabular and Femoral Neck Fracture Nonunion and Malunion