MHMark A. Haimes

Mark A. Haimes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mark A. Haimes has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Femoral Component Flexion in Robotic-Assisted Total Knee Arthroplasty on Retrograde Intramedullary Nail Sagittal Trajectory Angulation

    by Jason Brant, Michael Roberts, Nathaniel Nelms, Patrick Schottel, Mark Haimes, Michael Blankstein

    Background: In robotic-assisted total knee arthroplasty (RA-TKA), the femoral prosthesis is positioned independent of the intramedullary canal and frequently in flexion for function optimization. Femoral prosthesis flexion displaces retrograde intramedullary nail (rIMN) start point posteriorly potentially exacerbating hyperextension deformity in periprosthetic fracture (PPFx) fixation. The aim of this study was to determine the relationship between RA-TKA femoral component flexion with rIMN sagittal trajectory angulation. We hypothesized flexion of the femoral component increases nail sagittal angle. Methods: This is a single-center academic observational study including adult patients undergoing primary RA-TKA by 3 fellowship-trained arthroplasty surgeons between August 2023 and February 2024. Final femoral implant characteristics after knee gap balancing were obtained from intraoperative computerized tomography screenshots. Sagittal angle measurements of rIMN trajectory based on distal femoral nail start point and center of femoral shaft were measured using ImageJ software and compared with several variables with a focus on femoral component flexion for 10-mm and 12-mm nail sizes. Results: A total of 111 patients (61 female and 50 male) with a mean age of 67 years (SD 10) and height 168 cm (SD 11) were included. The mean femoral component flexion was 5.87° (SD 2.13), and the mean nail sagittal trajectory angle was 9.83° (SD 2.79) and 11.43° (SD 2.88) for the 10-mm and 12-mm nails, respectively. There was a significant linear correlation of a 0.50° increase in the mean sagittal angle for every 1.0° increase in femoral component flexion for both nail sizes (p < 0.001). Conclusions: There is a linear correlation between femoral component flexion and rIMN sagittal trajectory angle. The mean sagittal angulation was approximately 10°, and the mean component flexion was 6°. As number of RA-TKAs performed nationally is expected to increase, a rIMN with a distal bend designed to compensate for femoral component flexion could be considered to limit hyperextension deformity in distal femur PPFx fixation. Level of Evidence: Level IV. See Instructions for Authors for a complete description of levels of evidence.

  • A Novel Fluoroscopic Method for Assessing Rotational Malalignment of the Tibia

    by Michael S. Roberts, Mark A. Haimes, Pamela Vacek, Michael Blankstein, Patrick C. Schottel

    Objective: To evaluate the accuracy and reliability of a novel fluoroscopic technique for assessing tibial rotation and compare it with a previously described fluoroscopic method. Methods: A multiplanar circular ring external fixator was secured to the tibial diaphysis of 5 cadaveric lower extremity specimens. Using deformity correction software, the frame and tibia were programed to randomly rotate 5, 10, 15, 20, 25, and 30 degrees of internal and external rotation. After each rotation, 2 blinded, independent observers measured the degree of tibial rotation using 2 different fluoroscopic methods: the previously described “mortise” method and the novel “intermalleolar” method. A total of 65 measurements were made by each observer. Accuracy and interobserver reliability were calculated. Results: Both intermalleolar and mortise methods had a mean absolute rotational difference from the true torsion of 3 degrees (standard error 1; range, 0–10 degrees intermalleolar vs. 0–18 degrees mortise). We found that 98.5% (128/130) of measurements using the intermalleolar method were less than 10 degrees from the true rotation compared with 93.8% (122/130) using the mortise method. Both the intermalleolar and the mortise methods had excellent interobserver reliability (intraclass correlation coefficient 0.99 and 0.96, respectively). Conclusion: Measuring tibial rotation fluoroscopically using the intermalleolar method is both accurate and reliable. Compared with the previously described mortise method, it has similar accuracy and provides a value that approximates the true tibial rotation. Also, it can be used reliably and effectively intraoperatively to identify tibial malrotation and assist in intraoperative rotational corrections.


  • Total Knee Bartonella henselae Infection: An Unusual Manifestation of Cat Scratch Disease

    by Mark A. Haimes, Nathaniel J. Nelms

    Case: This is the first clinical report of periprosthetic total joint infection caused by Bartonella henselae. A 65-year-old woman developed an acutely painful total knee 3 weeks after a cat scratch. Serial joint aspirations and tissue cultures failed to identify any organism. Diagnosis was performed with polymerase chain reaction analysis. She underwent a 2-stage revision with successful symptom resolution. Conclusions: Bartonella is an unusual cause of total knee infection requiring alternative techniques for diagnosis because cultures are unlikely to be definitive.