AMAris Munandar

Aris Munandar

*This is an algorithmically generated author record based on publicly available information.

Aris Munandar has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Water quality assessment monitoring system using fuzzy logic and the internet of things

    by Hanif Fakhrurroja, Edi Triono Nuryatno, Aris Munandar, Muhammad Fahmi, Novan Agung Mahardiono

    Water utilization has recently been at its highest level of demand. The water needed to be clean, healthy, and determined to be suitable for consumption. Therefore, it is necessary to have a system that can monitor the water quality so thatinformation related to wate r suitability can be received regularly and in real-time. This paper addresses the critical need for real-time water quality monitoring systems. This study proposed a novel approach integrating the Tsukamoto fuzzy algorithm into an internet of things (IoT)-based framework, forming part of the Fuzzy Inference System. Our system serves as a decision support tool, enabling continuous assessment of water quality. The method categorizes water quality into three levels: good, moderate, and unhealthy, providing timely and precise suitability information. The results demonstrate the effectiveness of the fuzzy logic method in delivering accurate output. Through remotely deployed IoT devices, water suitability and status can be monitored and analyzed in real-time over the internet. This research bridges the gap between traditional water quality assessment methods and the demands of our modern, technology-driven society, ensuring a reliable supply of safe and consumable water.


  • Open Access

    An open-source parallel gripper with an embedded soft skin fingertip sensor

    by Muhammad Arifin, Rian Putra Pratama, Oka Mahendra, Aris Munandar, Catur Hilman Adritya Haryo Bhakti Baskoro, Muhtadin Muhtadin, Abdullah Iskandar

    The demand for implementing robots into our daily lives has surged in recent years, necessitating safe grasping for effective interaction with the environment. However, a majority of researchers rely on commercial grippers for their experimental studies, which are typically expensive and not accessible to everyone. Despite the existence of open-source designs, the assembly process is often challenging and requires modifications to enhance secure grasping. This paper presents a simple, compact, and low-cost gripper to offer an accessible and readily deployable solution for research and education. The gripper utilizes a parallel four-bar linkage mechanism, minimizing the number of components and incorporating off-the-shelf parts for straightforward assembly. Furthermore, to enhance its capabilities, the proposed gripper implements a soft skin tactile sensor on its fingertips. These sensors offer three-directional measurements using Hall effect sensing and embedded silicone. By controlling fingertip force based on information from the tactile sensors, the gripper achieves safe grasping. The gripper is evaluated to grasp daily life objects with different properties such as shapes, sizes, and levels of deformability. Evaluation results showcase the gripper's versatility, enabling it to securely grasp various objects, including fragile items. This outcome underscores the gripper's effectiveness, versatility, and safety in practical use.


  • Exploration of ECG-Based Real-Time Arrhythmia Detection: A Systematic Literature Review

    by Muhammad Ilham Rizqyawan, Edi Triono Nuryatno, Hanif Fakhrurroja, Aris Munandar, Jony Winaryo Wibowo, Dwi Esti Kusumandari, Artha Ivonita Simbolon, Dika Setiawan, M Faizal Amri, Ulfah Nadiya, et al.

    Cardiac arrhythmia is a medical term to describe an irregular heartbeat, which occurs when electrical properties in the heart incapacitated. Although most of arrhythmias are harmless, some of them can lead to life threatening complications if not detected and monitored on time. To date, a real-time automatic arrhythmia detection is essential in the current health system. This can be seen from numerous research that has been conducted on the automatic detection and classification of various types of arrhythmias. This study seeks to find as much relevant research on the abundance of published work in the topic, to identify the state-of-the art methods and finding the gap in the research in an effort to summarize all of the available evidence of the distinguish real-time automatic arrhythmia detection. A careful quantitative research process of systematic literature review (SLR) within the Health Informatics area was applied in this research to identify and analyze the trends, datasets, and methods in real-time arrhythmia detection. Systematic searches were administered in Scopus using a defined search string, while several filters were applied based on inclusion and exclusion criteria. After removing duplicates and non-eligible articles, the data were extracted from the selected articles with the result shows that the number of studies focusing on the real-time detection of arrhythmia is still limited, but on a rising trend. Finally, the analysis of the datasets, feature extraction, classification methods and a table of algorithm comparison were presented as the result of the study, which summarized the pre-eminent methods of real-time arrhythmia classification based on its average accuracy.