AAAdrian Anghelescu

Adrian Anghelescu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Adrian Anghelescu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Piezoelectric MEMS Energy Harvester for Low-Power Applications

    by George Muscalu, Bogdan Firtat, Adrian Anghelescu, Carmen Moldovan, Silviu Dinulescu, Costin Brasoveanu, Magdalena Ekwinska, Dariusz Szmigiel, Michal Zaborowski, Jerzy Zajac, et al.

    With the global market value of sensors on the rise, this paper focuses on the fabrication and testing of a proof-of-concept piezoelectric energy harvester which is able to harvest mechanical energy from the ambient environment and convert it into electrical energy in order to power wireless sensor networks. We focused on obtaining a new device structure based on a comb-type array of piezoelectric MEMS cantilevers (2 × 10) for a resonant frequency in the environmental application domain (a few hundred Hz) and a chip area of only 1 cm2. The configuration of the lead-free piezoelectric cantilever consists of a Si substrate, a pair of Ti-Pt electrodes and a sputtered piezoelectric layer of 12% Sc-doped AlN with a thickness of 1000 nm, a dielectric constant of ~13 and e31,f = 1.3 C/m2. At a resonant frequency of 465.2 Hz and an acceleration of 1 g, the maximum value for the collected power was 2.53 µW for an optimal load resistance of 1 MΩ resulting in a power density of 60.2 nW/mm3 for the unpacked device, without taking into account the vibration volume. By increasing the excitation acceleration to 2 g RMS and using LTC3588-1 for the power circuitry we were able to obtain a stabilized output voltage of 1.8 V.


  • Open Access

    Facile Electrodeposition-Based Chemosensors Using PANI and C-Hybrid Nanomaterials for the Selective Detection of Ammonia and Nitrogen Dioxide at Room Temperature

    by Alexandru Grigoroiu, Carmen-Marinela Mihailescu, Mihaela Savin, Carmen Aura Moldovan, Costin Brasoveanu, Silviu Dinulescu, Nikolay Djourelov, Georgescu Vlad Cristian, Oana Brincoveanu, Gabriel Craciun, et al.

    Sensor systems for monitoring indoor air quality are vital for the precise quantification of the mechanisms which lead to the deterioration of human health, with a typical person spending an average of 20 h a day in an enclosed space. Thus, a series of layered chemoresistive sensors, obtained by the facile electrodeposition of carbon nanomaterial-enhanced PANI composites, have been tested for the selective detection of two core indoor pollutants: ammonia and nitrogen dioxide. The sensors were tested with respect to sensitivity and selectivity to the target gasses, with performance being assessed based on response linearity and repeatability at room temperature. Of the tested sensors, two have been identified as having an adequate performance on ammonia, with sensitivities of up to 96.99% and resolutions of up to 0.85 ppm being observed, while on nitrogen dioxide, despite the successful sensor having a lower sensitivity, 10.71%, it has shown high resolution, 1.25 ppm, and linearity over a large concentration domain. These high performances highlight the viability of multi-layers chemosensors based on the electrodeposition of nanomaterial-enhanced conductive polymers for the detection of pollutant gasses, with finetuning of the detection layer allowing the accurate monitoring of a wide range of gasses.