Jenna Brown
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jenna Brown has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Zimmerle
Energy Institute, Colorado State University, Fort Collins, CO 80523, USA
6 shared publications - Fiji George
Cheniere Energy Inc
5 shared publications - Selina Roman-White
Cheniere Energy Inc
4 shared publications - Gregory Ross
Cheniere Energy Inc
3 shared publications - Matthew Harrison
SLR International
3 shared publications - Tecle Rufael
SLR International
3 shared publications
Latest Publications
- Open Access
- 31 August 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Measurement-Informed Methane Inventories for Colorado’s Upstream Oil and Gas Sector: Two Independent Modeling Approaches
The state of Colorado is recognized as a leader in regulating oil and gas methane emissions, with Colorado requirements often influencing subsequent federal policy. Building on existing efforts, Colorado published a greenhouse gas intensity verification rule in 2023, requiring upstream operators to either create their own measurement-informed emissions inventory or multiply their bottom-up inventory by a state-developed default factor. This factor is intended to address known deficiencies in bottom-up emissions reporting by increasing the bottom-up inventory to match measured emissions. In this paper, we describe the aerial measurement campaign and subsequent modeling approaches used to create the 2026 default factor. Three aerial technology vendors (Bridger Photonics, GHGSat, and Insight M) performed over 30,000 scans of production facilities across Colorado, covering roughly 94% of the state’s oil and gas production facilities that were operating or partially operating. Using these aerial measurements as inputs, two independent models were developed to estimate state-wide annual methane emissions. One model uses a discrete event simulation tool, Mechanistic Air Emissions Simulator (MAES), to estimate total emissions, while the other model, referred to as the statistical model, is purely data-driven and estimates a facility-level emission rate distribution from the measurement data. MAES and the statistical model estimate upstream oil and gas emissions of 38.7 (35.3, 44.6) and 97.7 (84.4, 114.7) Gg/y, respectively, which are 1.47 (1.34, 1.69) and 3.70 (3.19, 4.34) times higher than the state’s bottom-up inventory.
- 31 August 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessMeasurement-Informed Methane Inventories for Colorado’s Upstream Oil and Gas Sector: Two Independent Modeling Approaches
The state of Colorado is recognized as a leader in regulating oil and gas methane emissions, with Colorado requirements often influencing subsequent federal policy. Building on existing efforts, Colorado published a greenhouse gas intensity verification rule in 2023, requiring upstream operators to either create their own measurement-informed emissions inventory or multiply their bottom-up inventory by a state-developed default factor. This factor is intended to address known deficiencies in bottom-up emissions reporting by increasing the bottom-up inventory to match measured emissions. In this paper, we describe the aerial measurement campaign and subsequent modeling approaches used to create the 2026 default factor. Three aerial technology vendors (Bridger Photonics, GHGSat, and Insight M) performed over 30,000 scans of production facilities across Colorado, covering roughly 94% of the state’s oil and gas production facilities that were operating or partially operating. Using these aerial measurements as inputs, two independent models were developed to estimate state-wide annual methane emissions. One model uses a discrete event simulation tool, Mechanistic Air Emissions Simulator (MAES), to estimate total emissions, while the other model, referred to as the statistical model, is purely data-driven and estimates a facility-level emission rate distribution from the measurement data. MAES and the statistical model estimate upstream oil and gas emissions of 38.7 (35.3, 44.6) and 97.7 (84.4, 114.7) Gg/y, respectively, which are 1.47 (1.34, 1.69) and 3.70 (3.19, 4.34) times higher than the state’s bottom-up inventory.
- Open Access
- 28 July 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Tracking U.S. Liquefied Natural Gas Supply Chain Greenhouse Gas Emissions Intensity through Direct Measurements
Recent regulatory and voluntary initiatives to estimate supply chain greenhouse gas (GHG) emissions intensity of liquefied natural gas (LNG) have emphasized the use of direct measurements as activity-based national inventories tend to systematically underestimate GHG emission intensities. In this work, we synthesize results from a three-year measurement campaign across production, midstream, and liquefaction stages into a life cycle assessment (LCA) framework to assess the GHG emissions intensity of U.S. LNG supply chains. Measurement-informed GHG emission intensity ranges from 13.8 – 17.2 gCO2e/MJ LNG produced, about 19-39% higher than those derived from an activity-based inventory assessment. We also observe large variation in the contribution of each stage to the total supply chain emission intensity. Critically, we find that stages downstream of gas production account for up to 73% of the production to liquefaction GHG emission intensity of LNG. Thus, relying on aggregate production-only emission intensities as the basis to assess the emissions impact of the LNG or gas placed in the destination market is likely to underestimate, leading to potentially ineffective public or corporate policies.
- 28 July 2025
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessTracking U.S. Liquefied Natural Gas Supply Chain Greenhouse Gas Emissions Intensity through Direct Measurements
Recent regulatory and voluntary initiatives to estimate supply chain greenhouse gas (GHG) emissions intensity of liquefied natural gas (LNG) have emphasized the use of direct measurements as activity-based national inventories tend to systematically underestimate GHG emission intensities. In this work, we synthesize results from a three-year measurement campaign across production, midstream, and liquefaction stages into a life cycle assessment (LCA) framework to assess the GHG emissions intensity of U.S. LNG supply chains. Measurement-informed GHG emission intensity ranges from 13.8 – 17.2 gCO2e/MJ LNG produced, about 19-39% higher than those derived from an activity-based inventory assessment. We also observe large variation in the contribution of each stage to the total supply chain emission intensity. Critically, we find that stages downstream of gas production account for up to 73% of the production to liquefaction GHG emission intensity of LNG. Thus, relying on aggregate production-only emission intensities as the basis to assess the emissions impact of the LNG or gas placed in the destination market is likely to underestimate, leading to potentially ineffective public or corporate policies.
- Open Access
- 18 March 2025
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 2 (7) , 1136-1147
Integrating Technical Economic and Management Requirements for Successful Measurement Informed Inventory: A Case Study
- 18 March 2025
- Published by American Chemical Society (ACS) in ACS ES&T Air
- Vol. 2 (7) , 1136-1147
Open AccessIntegrating Technical Economic and Management Requirements for Successful Measurement Informed Inventory: A Case Study
- Open Access
- 3 April 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (4) , 447
Evaluating Development of Empirical Estimates Using Two Top-Down Methods at Midstream Natural Gas Facilities
To align with climate initiatives, multiple reporting programs are transitioning from generic activity-based emission factors to site-specific measured emissions data to estimate greenhouse gas emissions at oil and gas facilities. This study contemporaneously deployed two top-down (TD) aerial methods across 14 midstream facilities, building upon previous research in the field. The methods produced multiple whole-facility estimates at each facility, resulting in 773 individual paired estimates (same facility, same day), and robust mean estimates for each facility. Mean estimates for each facility, aggregated across all facilities, differed by nearly 2:1 (49% [32% to 69%]). At 6 of 14 facilities, the methods produced mean estimates that differed by more than a factor of two. These data suggest that one or both methods did not produce accurate facility-level estimates at a majority of facilities and in aggregate across all facilities. The overall results are augmented with two case studies where TD estimates at two pre-selected facilities were coupled with comprehensive onsite measurements to understand the factors driving the divergence between TD and bottom-up (BU) emissions estimates. In 3 of 4 paired comparisons between the intensive onsite estimates and one of the TD methods, the intensive onsite surveys did not conclusively diagnose the difference in estimates. In these cases, our work suggests that the TD methods mis-estimate emissions an unknown fraction of the time, for unknown reasons. While two methods were selected for this study, it is unlikely that the issues identified here are confined to these two methods; similar issues may exist for other similar whole-facility methods on midstream and/or other facility types. These findings have important implications for the construction of voluntary and regulatory reporting programs that rely on emission estimates for reporting fees or penalties, or for studies using whole-facility estimates to aggregate TD emissions to basin or regional estimates.
- 3 April 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (4) , 447
Open AccessEvaluating Development of Empirical Estimates Using Two Top-Down Methods at Midstream Natural Gas Facilities
To align with climate initiatives, multiple reporting programs are transitioning from generic activity-based emission factors to site-specific measured emissions data to estimate greenhouse gas emissions at oil and gas facilities. This study contemporaneously deployed two top-down (TD) aerial methods across 14 midstream facilities, building upon previous research in the field. The methods produced multiple whole-facility estimates at each facility, resulting in 773 individual paired estimates (same facility, same day), and robust mean estimates for each facility. Mean estimates for each facility, aggregated across all facilities, differed by nearly 2:1 (49% [32% to 69%]). At 6 of 14 facilities, the methods produced mean estimates that differed by more than a factor of two. These data suggest that one or both methods did not produce accurate facility-level estimates at a majority of facilities and in aggregate across all facilities. The overall results are augmented with two case studies where TD estimates at two pre-selected facilities were coupled with comprehensive onsite measurements to understand the factors driving the divergence between TD and bottom-up (BU) emissions estimates. In 3 of 4 paired comparisons between the intensive onsite estimates and one of the TD methods, the intensive onsite surveys did not conclusively diagnose the difference in estimates. In these cases, our work suggests that the TD methods mis-estimate emissions an unknown fraction of the time, for unknown reasons. While two methods were selected for this study, it is unlikely that the issues identified here are confined to these two methods; similar issues may exist for other similar whole-facility methods on midstream and/or other facility types. These findings have important implications for the construction of voluntary and regulatory reporting programs that rely on emission estimates for reporting fees or penalties, or for studies using whole-facility estimates to aggregate TD emissions to basin or regional estimates.
- Open Access
- 12 October 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Evaluating development of empirical estimates using two top-down methods at midstream natural gas facilities
To align with climate initiatives, multiple reporting programs are transitioning from generic activity-based emission factors to site-specific measured emissions data to estimate greenhouse gas emissions at oil and gas facilities. This study contemporaneously deployed two top-down (TD) aerial methods across 14 midstream facilities, extending work done in Brown et al.1. Methods produced multiple whole-facility estimates at each facility, resulting in 773 individual paired estimates (same facility, same day), and robust mean estimates for each facility. Mean estimates for each facility, aggregated across all facilities, differed by nearly 2:1 (49% [32% to 68%]). At 6 of 14 facilities, the methods produced mean estimates that differed by more than a factor of two. These data suggest that one or both methods did not produce accurate facility-level estimates, at a majority of facilities and in aggregate across all facilities. Overall results are augmented with two case studies where TD estimates at two pre-selected facilities were coupled with comprehensive onsite measurements to understand factors driving the divergence between TD and bottom-up (BU) emissions estimates. In 3 of 4 paired comparisons between the intensive onsite estimates and one of the TD methods, the intensive onsite surveys did not conclusively diagnose the difference in estimates. In these cases, our work suggests that the TD methods mis-estimate emissions an unknown fraction of the time, for unknown reasons. While two methods were selected for this study, it is unlikely that the issues identified here are confined to these two methods; similar issues may exist for other similar whole-facility methods, on midstream and/or other facility types. These findings have important implications for the construction of voluntary and regulatory reporting programs that rely on emission estimates for reporting, fees or penalties, or for studies using whole-facility estimates to aggregate TD emissions to basin or regional estimates.
- 12 October 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessEvaluating development of empirical estimates using two top-down methods at midstream natural gas facilities
To align with climate initiatives, multiple reporting programs are transitioning from generic activity-based emission factors to site-specific measured emissions data to estimate greenhouse gas emissions at oil and gas facilities. This study contemporaneously deployed two top-down (TD) aerial methods across 14 midstream facilities, extending work done in Brown et al.1. Methods produced multiple whole-facility estimates at each facility, resulting in 773 individual paired estimates (same facility, same day), and robust mean estimates for each facility. Mean estimates for each facility, aggregated across all facilities, differed by nearly 2:1 (49% [32% to 68%]). At 6 of 14 facilities, the methods produced mean estimates that differed by more than a factor of two. These data suggest that one or both methods did not produce accurate facility-level estimates, at a majority of facilities and in aggregate across all facilities. Overall results are augmented with two case studies where TD estimates at two pre-selected facilities were coupled with comprehensive onsite measurements to understand factors driving the divergence between TD and bottom-up (BU) emissions estimates. In 3 of 4 paired comparisons between the intensive onsite estimates and one of the TD methods, the intensive onsite surveys did not conclusively diagnose the difference in estimates. In these cases, our work suggests that the TD methods mis-estimate emissions an unknown fraction of the time, for unknown reasons. While two methods were selected for this study, it is unlikely that the issues identified here are confined to these two methods; similar issues may exist for other similar whole-facility methods, on midstream and/or other facility types. These findings have important implications for the construction of voluntary and regulatory reporting programs that rely on emission estimates for reporting, fees or penalties, or for studies using whole-facility estimates to aggregate TD emissions to basin or regional estimates.
- Open Access
- 20 September 2023
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 57 (39) , 14539-14547
Informing Methane Emissions Inventories Using Facility Aerial Measurements at Midstream Natural Gas Facilities
Increased interest in greenhouse gas (GHG) emissions, including recent legislative action and voluntary programs, has increased attention on quantifying and ultimately reducing methane emissions from the natural gas supply chain. While inventories used for public or corporate GHG policies have traditionally utilized bottom-up (BU) methods to estimate emissions, the validity of such inventories has been questioned. Therefore, there is attention on utilizing full-facility measurements using airborne, satellite, or drone (top-down (TD)) techniques to inform, improve, or validate inventories. This study utilized full-facility estimates from two independent TD methods at 15 midstream natural gas facilities in the U.S.A., which were compared with a contemporaneous daily inventory assembled by the facility operator, employing comprehensive inventory methods. Estimates from the two TD methods statistically agreed in 2 of 28 paired measurements. Operator inventories, which included extensions to capture sources beyond regular inventory requirements and integration of local measurements, estimated significantly lower emissions than the TD estimates for 40 of 43 paired comparisons. Significant disagreement was observed at most facilities, both between the two TD methods and between the TD estimates and operator inventory. These findings have two implications. First, improving inventory estimates will require additional on-site or ground-based diagnostic screening and measurement of all sources. Second, the TD full-facility measurement methods need to undergo further testing, characterization, and potential improvement specifically tailored for complex midstream facilities.
- 20 September 2023
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 57 (39) , 14539-14547
Open AccessInforming Methane Emissions Inventories Using Facility Aerial Measurements at Midstream Natural Gas Facilities
Increased interest in greenhouse gas (GHG) emissions, including recent legislative action and voluntary programs, has increased attention on quantifying and ultimately reducing methane emissions from the natural gas supply chain. While inventories used for public or corporate GHG policies have traditionally utilized bottom-up (BU) methods to estimate emissions, the validity of such inventories has been questioned. Therefore, there is attention on utilizing full-facility measurements using airborne, satellite, or drone (top-down (TD)) techniques to inform, improve, or validate inventories. This study utilized full-facility estimates from two independent TD methods at 15 midstream natural gas facilities in the U.S.A., which were compared with a contemporaneous daily inventory assembled by the facility operator, employing comprehensive inventory methods. Estimates from the two TD methods statistically agreed in 2 of 28 paired measurements. Operator inventories, which included extensions to capture sources beyond regular inventory requirements and integration of local measurements, estimated significantly lower emissions than the TD estimates for 40 of 43 paired comparisons. Significant disagreement was observed at most facilities, both between the two TD methods and between the TD estimates and operator inventory. These findings have two implications. First, improving inventory estimates will require additional on-site or ground-based diagnostic screening and measurement of all sources. Second, the TD full-facility measurement methods need to undergo further testing, characterization, and potential improvement specifically tailored for complex midstream facilities.
- Open Access
- 25 May 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Informing methane emissions inventories using facility aerial measurements at midstream natural gas facilities
Increased interest in greenhouse gas (GHG) emissions, including recent legislative action and voluntary programs, has increased attention on quantifying, and ultimately reducing, methane emissions from the natural gas supply chain. While inventories used for public or corporate GHG policies have traditionally utilized bottom-up (BU) methods to estimate emissions, the validity of such inventories has been questioned. Therefore, there is attention on utilizing full-facility measurements using airborne, satellite or drone (top-down (TD)) techniques to inform, improve, or validate inventories. This study utilized full-facility estimates from two independent TD methods at 15 midstream natural gas facilities in the U.S.A., and were compared with a contemporaneous daily inventory assembled by the facility operator, employing comprehensive inventory methods. Estimates from the two TD methods statistically agreed in 2 of 28 paired measurements. Operator inventories, which included extensions to capture sources beyond regular inventory requirements and to integrate local measurements, estimated significantly lower emissions than the TD estimates for 40 of 43 paired comparisons. Significant disagreement is observed at most facilities, both between the two TD methods and between the TD estimates and operator inventory. These findings have two implications. Firstly, improving inventory estimates will require additional on-site or ground-based diagnostic screening and measurement of all sources. Secondly, the TD full-facility measurement methods need to undergo further testing, characterization, and potential improvement specifically tailored for complex midstream facilities.
- 25 May 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessInforming methane emissions inventories using facility aerial measurements at midstream natural gas facilities
Increased interest in greenhouse gas (GHG) emissions, including recent legislative action and voluntary programs, has increased attention on quantifying, and ultimately reducing, methane emissions from the natural gas supply chain. While inventories used for public or corporate GHG policies have traditionally utilized bottom-up (BU) methods to estimate emissions, the validity of such inventories has been questioned. Therefore, there is attention on utilizing full-facility measurements using airborne, satellite or drone (top-down (TD)) techniques to inform, improve, or validate inventories. This study utilized full-facility estimates from two independent TD methods at 15 midstream natural gas facilities in the U.S.A., and were compared with a contemporaneous daily inventory assembled by the facility operator, employing comprehensive inventory methods. Estimates from the two TD methods statistically agreed in 2 of 28 paired measurements. Operator inventories, which included extensions to capture sources beyond regular inventory requirements and to integrate local measurements, estimated significantly lower emissions than the TD estimates for 40 of 43 paired comparisons. Significant disagreement is observed at most facilities, both between the two TD methods and between the TD estimates and operator inventory. These findings have two implications. Firstly, improving inventory estimates will require additional on-site or ground-based diagnostic screening and measurement of all sources. Secondly, the TD full-facility measurement methods need to undergo further testing, characterization, and potential improvement specifically tailored for complex midstream facilities.