Tecle Rufael
Research Subjects
Tecle Rufael has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Zimmerle
Energy Institute, Colorado State University, Fort Collins, CO 80523, USA
4 shared publications - Matthew Harrison
SLR International
4 shared publications - Fiji George
Cheniere Energy Inc
3 shared publications - Gregory Ross
Cheniere Energy Inc
3 shared publications - Jenna Brown
Colorado State University
3 shared publications - Selina Roman-White
Cheniere Energy Inc
3 shared publications
Latest Publications
- Open Access
Beyond Snapshots: Building Methane Measurement-Informed Inventories for Midstream Oil and Gas Sites in the Appalachian Basin
This paper presents the application of a novel methodology to build a comprehensive Measurement-Informed Inventory (MII) by integrating unreported emissions into government inventories. These emissions are often excluded from current regulatory requirements or associated with upset conditions, and are identified through aerial surveys and confirmed by oil and gas (O&G) operators. This methodology utilizes the Mechanistic Air Emissions Simulator (MAES) tool to generate spatially and temporally resolved emission estimates for O&G sites, using annual inventory data submitted to the Greenhouse Gas Reporting Program (GHGRP) and quarterly aerial surveys conducted in 2023 by Bridger Photonics at partner-operated sites in the Appalachian Basin. The analysis is part of the Appalachian Methane Initiative (AMI) coalition efforts to improve methane emissions characterization and mitigation efforts in the Appalachian Basin. On average, results show that emissions from the MII models are 58.9% higher than the emissions reported to the GHGRP for reporting year 2022 (submitted in 2023) for these facilities, which was the most recent inventory available at the time of the 2023 surveys, when the reported total is restricted to normal operation. Measured against the total reported inventory, which includes 479.2 mt/year of operator-reported fugitive emissions, the increase is 40.0%. Site-level methane emission rates exceeding 15 kg/h are estimated to account for 94.9% of total emissions across all midstream sites, while rates above the 95th percentile of the site-level distribution (105 kg/h) contribute 33.4%, highlighting the disproportionate influence of large emitters. These results are based on 19 partner-operated facilities from two operators and are not a representative sample of the Appalachian midstream sector. The simulated average loss rate for the participating companies under analysis was 6.45 × 10−4, lower than the loss rate values reported in the literature for this sector, which span different supply chain scopes. The principal contribution of this work is methodological: it shows how aerial observations, operator-provided information, and a stochastic facility model can be combined to account for the tail end of the emissions distribution that is often absent from conventional bottom-up (BU) estimates, and it indicates that aerial campaigns optimized to detect events from upset conditions can support more accurate MIIs.
Open AccessBeyond Snapshots: Building Methane Measurement-Informed Inventories for Midstream Oil and Gas Sites in the Appalachian Basin
This paper presents the application of a novel methodology to build a comprehensive Measurement-Informed Inventory (MII) by integrating unreported emissions into government inventories. These emissions are often excluded from current regulatory requirements or associated with upset conditions, and are identified through aerial surveys and confirmed by oil and gas (O&G) operators. This methodology utilizes the Mechanistic Air Emissions Simulator (MAES) tool to generate spatially and temporally resolved emission estimates for O&G sites, using annual inventory data submitted to the Greenhouse Gas Reporting Program (GHGRP) and quarterly aerial surveys conducted in 2023 by Bridger Photonics at partner-operated sites in the Appalachian Basin. The analysis is part of the Appalachian Methane Initiative (AMI) coalition efforts to improve methane emissions characterization and mitigation efforts in the Appalachian Basin. On average, results show that emissions from the MII models are 58.9% higher than the emissions reported to the GHGRP for reporting year 2022 (submitted in 2023) for these facilities, which was the most recent inventory available at the time of the 2023 surveys, when the reported total is restricted to normal operation. Measured against the total reported inventory, which includes 479.2 mt/year of operator-reported fugitive emissions, the increase is 40.0%. Site-level methane emission rates exceeding 15 kg/h are estimated to account for 94.9% of total emissions across all midstream sites, while rates above the 95th percentile of the site-level distribution (105 kg/h) contribute 33.4%, highlighting the disproportionate influence of large emitters. These results are based on 19 partner-operated facilities from two operators and are not a representative sample of the Appalachian midstream sector. The simulated average loss rate for the participating companies under analysis was 6.45 × 10−4, lower than the loss rate values reported in the literature for this sector, which span different supply chain scopes. The principal contribution of this work is methodological: it shows how aerial observations, operator-provided information, and a stochastic facility model can be combined to account for the tail end of the emissions distribution that is often absent from conventional bottom-up (BU) estimates, and it indicates that aerial campaigns optimized to detect events from upset conditions can support more accurate MIIs.
- Open Access
- 3 April 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (4) , 447
Evaluating Development of Empirical Estimates Using Two Top-Down Methods at Midstream Natural Gas Facilities
To align with climate initiatives, multiple reporting programs are transitioning from generic activity-based emission factors to site-specific measured emissions data to estimate greenhouse gas emissions at oil and gas facilities. This study contemporaneously deployed two top-down (TD) aerial methods across 14 midstream facilities, building upon previous research in the field. The methods produced multiple whole-facility estimates at each facility, resulting in 773 individual paired estimates (same facility, same day), and robust mean estimates for each facility. Mean estimates for each facility, aggregated across all facilities, differed by nearly 2:1 (49% [32% to 69%]). At 6 of 14 facilities, the methods produced mean estimates that differed by more than a factor of two. These data suggest that one or both methods did not produce accurate facility-level estimates at a majority of facilities and in aggregate across all facilities. The overall results are augmented with two case studies where TD estimates at two pre-selected facilities were coupled with comprehensive onsite measurements to understand the factors driving the divergence between TD and bottom-up (BU) emissions estimates. In 3 of 4 paired comparisons between the intensive onsite estimates and one of the TD methods, the intensive onsite surveys did not conclusively diagnose the difference in estimates. In these cases, our work suggests that the TD methods mis-estimate emissions an unknown fraction of the time, for unknown reasons. While two methods were selected for this study, it is unlikely that the issues identified here are confined to these two methods; similar issues may exist for other similar whole-facility methods on midstream and/or other facility types. These findings have important implications for the construction of voluntary and regulatory reporting programs that rely on emission estimates for reporting fees or penalties, or for studies using whole-facility estimates to aggregate TD emissions to basin or regional estimates.
- 3 April 2024
- Published by MDPI AG in Atmosphere
- Vol. 15 (4) , 447
Open AccessEvaluating Development of Empirical Estimates Using Two Top-Down Methods at Midstream Natural Gas Facilities
To align with climate initiatives, multiple reporting programs are transitioning from generic activity-based emission factors to site-specific measured emissions data to estimate greenhouse gas emissions at oil and gas facilities. This study contemporaneously deployed two top-down (TD) aerial methods across 14 midstream facilities, building upon previous research in the field. The methods produced multiple whole-facility estimates at each facility, resulting in 773 individual paired estimates (same facility, same day), and robust mean estimates for each facility. Mean estimates for each facility, aggregated across all facilities, differed by nearly 2:1 (49% [32% to 69%]). At 6 of 14 facilities, the methods produced mean estimates that differed by more than a factor of two. These data suggest that one or both methods did not produce accurate facility-level estimates at a majority of facilities and in aggregate across all facilities. The overall results are augmented with two case studies where TD estimates at two pre-selected facilities were coupled with comprehensive onsite measurements to understand the factors driving the divergence between TD and bottom-up (BU) emissions estimates. In 3 of 4 paired comparisons between the intensive onsite estimates and one of the TD methods, the intensive onsite surveys did not conclusively diagnose the difference in estimates. In these cases, our work suggests that the TD methods mis-estimate emissions an unknown fraction of the time, for unknown reasons. While two methods were selected for this study, it is unlikely that the issues identified here are confined to these two methods; similar issues may exist for other similar whole-facility methods on midstream and/or other facility types. These findings have important implications for the construction of voluntary and regulatory reporting programs that rely on emission estimates for reporting fees or penalties, or for studies using whole-facility estimates to aggregate TD emissions to basin or regional estimates.
- Open Access
- 12 October 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Evaluating development of empirical estimates using two top-down methods at midstream natural gas facilities
To align with climate initiatives, multiple reporting programs are transitioning from generic activity-based emission factors to site-specific measured emissions data to estimate greenhouse gas emissions at oil and gas facilities. This study contemporaneously deployed two top-down (TD) aerial methods across 14 midstream facilities, extending work done in Brown et al.1. Methods produced multiple whole-facility estimates at each facility, resulting in 773 individual paired estimates (same facility, same day), and robust mean estimates for each facility. Mean estimates for each facility, aggregated across all facilities, differed by nearly 2:1 (49% [32% to 68%]). At 6 of 14 facilities, the methods produced mean estimates that differed by more than a factor of two. These data suggest that one or both methods did not produce accurate facility-level estimates, at a majority of facilities and in aggregate across all facilities. Overall results are augmented with two case studies where TD estimates at two pre-selected facilities were coupled with comprehensive onsite measurements to understand factors driving the divergence between TD and bottom-up (BU) emissions estimates. In 3 of 4 paired comparisons between the intensive onsite estimates and one of the TD methods, the intensive onsite surveys did not conclusively diagnose the difference in estimates. In these cases, our work suggests that the TD methods mis-estimate emissions an unknown fraction of the time, for unknown reasons. While two methods were selected for this study, it is unlikely that the issues identified here are confined to these two methods; similar issues may exist for other similar whole-facility methods, on midstream and/or other facility types. These findings have important implications for the construction of voluntary and regulatory reporting programs that rely on emission estimates for reporting, fees or penalties, or for studies using whole-facility estimates to aggregate TD emissions to basin or regional estimates.
- 12 October 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessEvaluating development of empirical estimates using two top-down methods at midstream natural gas facilities
To align with climate initiatives, multiple reporting programs are transitioning from generic activity-based emission factors to site-specific measured emissions data to estimate greenhouse gas emissions at oil and gas facilities. This study contemporaneously deployed two top-down (TD) aerial methods across 14 midstream facilities, extending work done in Brown et al.1. Methods produced multiple whole-facility estimates at each facility, resulting in 773 individual paired estimates (same facility, same day), and robust mean estimates for each facility. Mean estimates for each facility, aggregated across all facilities, differed by nearly 2:1 (49% [32% to 68%]). At 6 of 14 facilities, the methods produced mean estimates that differed by more than a factor of two. These data suggest that one or both methods did not produce accurate facility-level estimates, at a majority of facilities and in aggregate across all facilities. Overall results are augmented with two case studies where TD estimates at two pre-selected facilities were coupled with comprehensive onsite measurements to understand factors driving the divergence between TD and bottom-up (BU) emissions estimates. In 3 of 4 paired comparisons between the intensive onsite estimates and one of the TD methods, the intensive onsite surveys did not conclusively diagnose the difference in estimates. In these cases, our work suggests that the TD methods mis-estimate emissions an unknown fraction of the time, for unknown reasons. While two methods were selected for this study, it is unlikely that the issues identified here are confined to these two methods; similar issues may exist for other similar whole-facility methods, on midstream and/or other facility types. These findings have important implications for the construction of voluntary and regulatory reporting programs that rely on emission estimates for reporting, fees or penalties, or for studies using whole-facility estimates to aggregate TD emissions to basin or regional estimates.
- Open Access
- 25 May 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Informing methane emissions inventories using facility aerial measurements at midstream natural gas facilities
Increased interest in greenhouse gas (GHG) emissions, including recent legislative action and voluntary programs, has increased attention on quantifying, and ultimately reducing, methane emissions from the natural gas supply chain. While inventories used for public or corporate GHG policies have traditionally utilized bottom-up (BU) methods to estimate emissions, the validity of such inventories has been questioned. Therefore, there is attention on utilizing full-facility measurements using airborne, satellite or drone (top-down (TD)) techniques to inform, improve, or validate inventories. This study utilized full-facility estimates from two independent TD methods at 15 midstream natural gas facilities in the U.S.A., and were compared with a contemporaneous daily inventory assembled by the facility operator, employing comprehensive inventory methods. Estimates from the two TD methods statistically agreed in 2 of 28 paired measurements. Operator inventories, which included extensions to capture sources beyond regular inventory requirements and to integrate local measurements, estimated significantly lower emissions than the TD estimates for 40 of 43 paired comparisons. Significant disagreement is observed at most facilities, both between the two TD methods and between the TD estimates and operator inventory. These findings have two implications. Firstly, improving inventory estimates will require additional on-site or ground-based diagnostic screening and measurement of all sources. Secondly, the TD full-facility measurement methods need to undergo further testing, characterization, and potential improvement specifically tailored for complex midstream facilities.
- 25 May 2023
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessInforming methane emissions inventories using facility aerial measurements at midstream natural gas facilities
Increased interest in greenhouse gas (GHG) emissions, including recent legislative action and voluntary programs, has increased attention on quantifying, and ultimately reducing, methane emissions from the natural gas supply chain. While inventories used for public or corporate GHG policies have traditionally utilized bottom-up (BU) methods to estimate emissions, the validity of such inventories has been questioned. Therefore, there is attention on utilizing full-facility measurements using airborne, satellite or drone (top-down (TD)) techniques to inform, improve, or validate inventories. This study utilized full-facility estimates from two independent TD methods at 15 midstream natural gas facilities in the U.S.A., and were compared with a contemporaneous daily inventory assembled by the facility operator, employing comprehensive inventory methods. Estimates from the two TD methods statistically agreed in 2 of 28 paired measurements. Operator inventories, which included extensions to capture sources beyond regular inventory requirements and to integrate local measurements, estimated significantly lower emissions than the TD estimates for 40 of 43 paired comparisons. Significant disagreement is observed at most facilities, both between the two TD methods and between the TD estimates and operator inventory. These findings have two implications. Firstly, improving inventory estimates will require additional on-site or ground-based diagnostic screening and measurement of all sources. Secondly, the TD full-facility measurement methods need to undergo further testing, characterization, and potential improvement specifically tailored for complex midstream facilities.