MYMehmet Yalım

Mehmet Yalım

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mehmet Yalım has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Relationship of Papilla Fill and Peri-Implant Esthetic Parameters with Radiographic Findings in Anterior Single-Tooth Implants

    by Hande Nur Karaman, Mehmet Yalim

    Objectives: To evaluate the relationship between papilla fill, peri-implant esthetic outcomes, and radiographic parameters in anterior single-tooth implants, and to assess the clinical applicability of the Complex Esthetic Index (CEI). Materials and Methods: This cross-sectional study included 38 systemically healthy adults (28 females and 10 males; 18–65 years) with 45 anterior single-tooth implants functioning for at least one year. Clinical parameters, including plaque index, gingival index, bleeding on probing, and probing depth, were recorded. Esthetic outcomes were assessed using the CEI. Interproximal bone levels and apicocoronal implant position were measured on standardized periapical radiographs using ImageJ software, version 1.53 (National Institutes of Health, Bethesda, MD, USA). Results: Plaque index and gingival index values were significantly lower around implants than whole-mouth averages (p < 0.001 and p = 0.018, respectively), whereas probing depth was significantly greater at implant sites (p < 0.001). Bleeding on probing did not differ significantly between implant and natural tooth sites. Interproximal bone level was significantly associated with papilla fill, with complete papilla fill decreasing when the contact point-to-bone crest distance exceeded 5 mm (mesial p = 0.005; distal p = 0.003). Apicocoronal implant position was significantly associated with vertical soft-tissue level (p < 0.001). Conclusions: Interproximal bone support is significantly associated with papilla fill in anterior single-tooth implants. Nevertheless, peri-implant esthetic outcomes are influenced by a combination of hard- and soft-tissue characteristics, surgical factors, and prosthetic design. The CEI is a useful clinical tool for comprehensive esthetic evaluation.

  • Immunohistochemical analysis with apoptosis and autophagy markers in periodontitis and peri‐implantitis: Clinical comparative study

    by Ozkan Ozkocer, Suheyla Esra Ozkocer, Berceste Guler, Ahu Uraz Corekci, Cigdem Elmas, Mehmet Yalım

    Background and Objectives: Recently, the terms autophagy and apoptosis have been studied on implants, especially in cell culture and in vitro studies, but in vivo evaluations are limited. The aim of this study was to compare the differences in apoptosis and autophagy intensity at the molecular and cellular level in periodontal and peri‐implant diseases.Methods: Sixty‐four biopsy samples were obtained from 52 patients, 36 female and 16 male, whose mean age was between 18 and 75, and were included in the study. The periodontitis group was defined as PG (n:30 sample) and the peri‐implantitis group as IG (n:34 samples). Granulation tissues as biopsy materials were collected, and immunohistochemical analysis was performed with hematoxylin–eosin, Masson's trichrome, anti‐MAP1LC3A, anti‐beclin, and anti‐active caspase‐3 antibodies and terminal TdT‐mediated dUTP‐biotin nick end labeling (TUNEL) methods. The histological slide images were evaluated with the ImageJ software program. Inflammatory cell density in epithelial tissue, inflammatory cell density in connective tissue, the density of necrotic tissue debris, and collagen density in connective tissue were scored between 0 and 3 (0: none, 1: minimal, 2: moderate, 3: severe by hematoxylin–eosin and Masson's trichrome). The antibody binding reaction areas were evaluated per unit area (mm2) in connective tissue by immunohistochemical examination.Results: As histochemical evaluations, there was no statistically significant differences the mean inflammatory cell density value in the epithelial tissue, inflammatory cell density value in the connective tissue, density value of necrotic tissue debris, collagen density value in the connective tissue between the groups. There was no statistically significant difference on immunohistochemical staining with LC3, caspase‐3, Beclin‐1 and TUNEL between the two groups (p > .05).Conclusions: A higher rate of inflammatory accumulation was shown on peri‐implantitis, but no difference was found between periodontitis and peri‐implantitis according to autophagy and apoptosis markers. Studies with high sample sizes with different markers are needed.


  • Open Access

    Chemical Evaluation of Energy Dispersive X-ray Spectroscopy Analysis of Different Failing Dental Implant Surfaces: A Comparative Clinical Trial

    by Berceste Guler, Ahu Uraz, Hasan Hatipoğlu, Mehmet Yalım

    The aim of the present study is to compare two different implant surface chemistries of failing dental implants. Sixteen patients (mean age: 52 ± 8.27 with eight females and eight males) and 34 implants were included in the study. Group-I implants consisted of a blasted/etched surface with a final process surface, while Group-II implants consisted of the sandblasted acid etching (SLA) method. The chemical surface analysis was performed by the energy dispersive X-ray spectroscopy (EDX) method from coronal, middle, and apical parts of each implant. Titanium (Ti) element values were found to be 20.22 ± 15.7 at.% in Group I and 33.96 ± 13.62 at.% in Group-II in the middle of the dental implants. Aluminum (Al) element values were found to be 0.01 ± 0.002 in Group-I and 0.17 ± 0.28 at.% in Group II in the middle of the dental implants, and statistically significant differences were found between the groups for the Al and Ti elements in the middle of the dental implants (p < 0.05). There was a statistically significant difference for the Ti, Al, O, Ca, Fe, P, and Mg elements in the coronal, middle, and apical parts of the implants in the intragroup evaluation (p < 0.05). It is reported that different parts of the implants affected by peri-implant inflammation show different surface chemistries, from coronal to apical, but there is no difference in the implants with different surfaces.