Chemical Evaluation of Energy Dispersive X-ray Spectroscopy Analysis of Different Failing Dental Implant Surfaces: A Comparative Clinical Trial
Open Access
Abstract
The aim of the present study is to compare two different implant surface chemistries of failing dental implants. Sixteen patients (mean age: 52 ± 8.27 with eight females and eight males) and 34 implants were included in the study. Group-I implants consisted of a blasted/etched surface with a final process surface, while Group-II implants consisted of the sandblasted acid etching (SLA) method. The chemical surface analysis was performed by the energy dispersive X-ray spectroscopy (EDX) method from coronal, middle, and apical parts of each implant. Titanium (Ti) element values were found to be 20.22 ± 15.7 at.% in Group I and 33.96 ± 13.62 at.% in Group-II in the middle of the dental implants. Aluminum (Al) element values were found to be 0.01 ± 0.002 in Group-I and 0.17 ± 0.28 at.% in Group II in the middle of the dental implants, and statistically significant differences were found between the groups for the Al and Ti elements in the middle of the dental implants (p < 0.05). There was a statistically significant difference for the Ti, Al, O, Ca, Fe, P, and Mg elements in the coronal, middle, and apical parts of the implants in the intragroup evaluation (p < 0.05). It is reported that different parts of the implants affected by peri-implant inflammation show different surface chemistries, from coronal to apical, but there is no difference in the implants with different surfaces.Keywords
Funding Information
- Dumlupinar Üniversitesi (2017-29)
This publication has 41 references indexed in Scilit:
- A Prospective, Multicenter, Randomized‐Controlled 5‐Year Study of Hybrid and Fully Etched Implants for the Incidence of Peri‐ImplantitisJournal of Periodontology, 2010
- Hydrogen Sulfide Production From Cysteine and Homocysteine by Periodontal and Oral BacteriaJournal of Periodontology, 2009
- An overview of the corrosion aspect of dental implants (titanium and its alloys)Indian Journal of Dental Research, 2009
- Implant Success, Survival, and Failure: The International Congress of Oral Implantologists (ICOI) Pisa Consensus ConferenceImplant Dentistry, 2008
- Effect of material characteristics and/or surface topography on biofilm developmentClinical Oral Implants Research, 2006
- Analysis of Failed Commercially Pure Titanium Dental Implants: A Scanning Electron Microscopy and Energy‐Dispersive Spectrometer X‐Ray StudyJournal of Periodontology, 2005
- Biomaterials: Where We Have Been and Where We Are GoingAnnual Review of Biomedical Engineering, 2004
- Oral rehabilitation with implant‐supported fixed partial dentures in periodontitis‐susceptible subjectsJournal of Clinical Periodontology, 2004
- Quantitative and qualitative investigations of surface enlarged titanium and titanium alloy implantsClinical Oral Implants Research, 1998
- Titanium with different oxides: in vitro studies of protein adsorption and contact activationBiomaterials, 1994