Longsheng Cheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Longsheng Cheng has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Chaofeng Ye
ShanghaiTech University
3 shared publications - Sitong Chen
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
2 shared publications - Yaqiong Niu
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
2 shared publications Sitong Chen
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
1 shared publicationYaqiong Niu
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
1 shared publication- Yutong Wei
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
1 shared publication
Latest Publications
- Open Access
- 29 April 2025
- Published by IOS Press
- p. 48-53
Magnetic Field Tuning for Multi-Channel Atomic Magnetometers Based on Artificial Neural Network
The optically pumped magnetometer (OPM) operating in spin exchange relaxation-free (SERF) regime is a kind of magnetic sensor that has ultra-high sensitivity. SERF OPMs need to operate in a near zero magnetic field environment. In many applications, multi-channel OPMs are utilized to measure the magnetic field at different observation points, where the magnetic fields generated by the OPMs interfere with each other. To suppress the magnetic field interference, this paper proposes a magnetic field compensation method based on an artificial neural network (ANN). The transfer function between the compensation currents and the observed signals is derived, based on which a nonlinear multiparameter optimization problem is derived. Experimental data with different initial magnetic field conditions is collected. Then, an ANN model is employed to optimize the compensation currents of the OPMs to minimize the magnetic field experienced by each sensor. It is demonstrated that this method can effectively reduce the magnetic field crosstalk of multi-channel OPMs.
- 29 April 2025
- Published by IOS Press
- p. 48-53
Open AccessMagnetic Field Tuning for Multi-Channel Atomic Magnetometers Based on Artificial Neural Network
The optically pumped magnetometer (OPM) operating in spin exchange relaxation-free (SERF) regime is a kind of magnetic sensor that has ultra-high sensitivity. SERF OPMs need to operate in a near zero magnetic field environment. In many applications, multi-channel OPMs are utilized to measure the magnetic field at different observation points, where the magnetic fields generated by the OPMs interfere with each other. To suppress the magnetic field interference, this paper proposes a magnetic field compensation method based on an artificial neural network (ANN). The transfer function between the compensation currents and the observed signals is derived, based on which a nonlinear multiparameter optimization problem is derived. Experimental data with different initial magnetic field conditions is collected. Then, an ANN model is employed to optimize the compensation currents of the OPMs to minimize the magnetic field experienced by each sensor. It is demonstrated that this method can effectively reduce the magnetic field crosstalk of multi-channel OPMs.
- 1 April 2025
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 78 (1-3) , 240-244
Elimination of the AC modulation mutual interference for array optically pumped magnetometers
The optically pumped magnetometer (OPM) is one of the most sensitive magnetic field sensors, which is widely used for ultra-weak magnetic field measurement. To localize and quantify the magnetic source, array OPMs are needed to work simultaneously in a small area. As an OPM typically employs a modulation magnetic field, in the presence of multiple sensors, the modulation fields of the OPMs interference with each other, resulting in reduced measurement accuracy and sensitivity. This paper proposes a novel array OPMs setting to eliminate the mutual interference of the modulation magnetic field. The OPMs in the array are modulated simultaneously by a group of coils, which are optimized based on the numerical calculation to generate an almost uniform magnetic field in the sensor areas. The operating principle of the method is analyzed by solving the Bloch equation. Then, the feasibility of the method is demonstrated experimentally with compact OPMs that measure the magnetocardiography signal of human body.
- 1 April 2025
- Published by SAGE Publications in International Journal of Applied Electromagnetics and Mechanics
- Vol. 78 (1-3) , 240-244
Elimination of the AC modulation mutual interference for array optically pumped magnetometers
The optically pumped magnetometer (OPM) is one of the most sensitive magnetic field sensors, which is widely used for ultra-weak magnetic field measurement. To localize and quantify the magnetic source, array OPMs are needed to work simultaneously in a small area. As an OPM typically employs a modulation magnetic field, in the presence of multiple sensors, the modulation fields of the OPMs interference with each other, resulting in reduced measurement accuracy and sensitivity. This paper proposes a novel array OPMs setting to eliminate the mutual interference of the modulation magnetic field. The OPMs in the array are modulated simultaneously by a group of coils, which are optimized based on the numerical calculation to generate an almost uniform magnetic field in the sensor areas. The operating principle of the method is analyzed by solving the Bloch equation. Then, the feasibility of the method is demonstrated experimentally with compact OPMs that measure the magnetocardiography signal of human body.
- 13 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Nested Magnetic Field Compensation With Regulated Coefficients for Bio-Magnetic Field Measurement
For a spin-exchange relaxation free (SERF) optically pumped magnetometer (OPM) that obtains its best performance in a zero magnetic field, an operation environment with approximately zero magnetic field is desired. This paper proposes a nested magnetic field compensation system for a magnetic shielding room (MSR) to suppress the magnetic field. Two sets of coils, one set located outside of the MSR and the other one placed inside of the MSR are combined in the system. The magnetic fields outside of the MSR are measured by tunneling magnetoresistance (TMR) sensors, while the fields inside the MSR are monitored by SERF OPMs. The two kinds of sensors complement each other in terms of measurement range and sensitivity. A nested two-stage proportional-integral (PI) closed-loop control strategy is employed to compensate for the magnetic field inside the MSR. The control parameters are regulated by the magnitude of the magnetic field to take advantage of the two kinds of sensors. The effect of the proposed system is experimentally tested. The three-axis field fluctuations are reduced by 97.52%, 98%, and 98.64% by the proposed method, respectively. The proposed method is compared with a conventional two-stage series PI control system. The x-axis magnetic field fluctuations of the conventional PI control system and the proposed system are 75.81 pT and 11.71 pT, respectively. The magnetic fluctuation of the proposed system is about 15.5% of the fluctuation of the conventional PI system. To validate the feasibility of the proposed magnetic field compensation system for ultra-weak bio-magnetic field measurement, magnetocardiography (MCG) and magnetoencephalography (MEG) signals are measured.
- 13 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Nested Magnetic Field Compensation With Regulated Coefficients for Bio-Magnetic Field Measurement
For a spin-exchange relaxation free (SERF) optically pumped magnetometer (OPM) that obtains its best performance in a zero magnetic field, an operation environment with approximately zero magnetic field is desired. This paper proposes a nested magnetic field compensation system for a magnetic shielding room (MSR) to suppress the magnetic field. Two sets of coils, one set located outside of the MSR and the other one placed inside of the MSR are combined in the system. The magnetic fields outside of the MSR are measured by tunneling magnetoresistance (TMR) sensors, while the fields inside the MSR are monitored by SERF OPMs. The two kinds of sensors complement each other in terms of measurement range and sensitivity. A nested two-stage proportional-integral (PI) closed-loop control strategy is employed to compensate for the magnetic field inside the MSR. The control parameters are regulated by the magnitude of the magnetic field to take advantage of the two kinds of sensors. The effect of the proposed system is experimentally tested. The three-axis field fluctuations are reduced by 97.52%, 98%, and 98.64% by the proposed method, respectively. The proposed method is compared with a conventional two-stage series PI control system. The x-axis magnetic field fluctuations of the conventional PI control system and the proposed system are 75.81 pT and 11.71 pT, respectively. The magnetic fluctuation of the proposed system is about 15.5% of the fluctuation of the conventional PI system. To validate the feasibility of the proposed magnetic field compensation system for ultra-weak bio-magnetic field measurement, magnetocardiography (MCG) and magnetoencephalography (MEG) signals are measured.