SCSitong Chen

Sitong Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sitong Chen has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Magnetic Field Tuning for Multi-Channel Atomic Magnetometers Based on Artificial Neural Network

    by Sitong Chen, Longsheng Cheng, Yaqiong Niu, Zhicheng Zou, Chaofeng Ye

    The optically pumped magnetometer (OPM) operating in spin exchange relaxation-free (SERF) regime is a kind of magnetic sensor that has ultra-high sensitivity. SERF OPMs need to operate in a near zero magnetic field environment. In many applications, multi-channel OPMs are utilized to measure the magnetic field at different observation points, where the magnetic fields generated by the OPMs interfere with each other. To suppress the magnetic field interference, this paper proposes a magnetic field compensation method based on an artificial neural network (ANN). The transfer function between the compensation currents and the observed signals is derived, based on which a nonlinear multiparameter optimization problem is derived. Experimental data with different initial magnetic field conditions is collected. Then, an ANN model is employed to optimize the compensation currents of the OPMs to minimize the magnetic field experienced by each sensor. It is demonstrated that this method can effectively reduce the magnetic field crosstalk of multi-channel OPMs.

  • Nested Magnetic Field Compensation With Regulated Coefficients for Bio-Magnetic Field Measurement

    by Yutong Wei, Longsheng Cheng, Yaqiong Niu, Sitong Chen, Chaofeng Ye

    For a spin-exchange relaxation free (SERF) optically pumped magnetometer (OPM) that obtains its best performance in a zero magnetic field, an operation environment with approximately zero magnetic field is desired. This paper proposes a nested magnetic field compensation system for a magnetic shielding room (MSR) to suppress the magnetic field. Two sets of coils, one set located outside of the MSR and the other one placed inside of the MSR are combined in the system. The magnetic fields outside of the MSR are measured by tunneling magnetoresistance (TMR) sensors, while the fields inside the MSR are monitored by SERF OPMs. The two kinds of sensors complement each other in terms of measurement range and sensitivity. A nested two-stage proportional-integral (PI) closed-loop control strategy is employed to compensate for the magnetic field inside the MSR. The control parameters are regulated by the magnitude of the magnetic field to take advantage of the two kinds of sensors. The effect of the proposed system is experimentally tested. The three-axis field fluctuations are reduced by 97.52%, 98%, and 98.64% by the proposed method, respectively. The proposed method is compared with a conventional two-stage series PI control system. The x-axis magnetic field fluctuations of the conventional PI control system and the proposed system are 75.81 pT and 11.71 pT, respectively. The magnetic fluctuation of the proposed system is about 15.5% of the fluctuation of the conventional PI system. To validate the feasibility of the proposed magnetic field compensation system for ultra-weak bio-magnetic field measurement, magnetocardiography (MCG) and magnetoencephalography (MEG) signals are measured.