ZLZhengtian Li

Zhengtian Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhengtian Li has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Enhancing Superimposed-Based Distance Protection in Inverter-Dominated Grids Based on Control-Protection Coordination

    by Kaijie Wang, Xiangning Lin, Fanrong Wei, Zhengtian Li, Jingyi Gao, Hanli Weng

    The external equivalence of inverter interfaced distributed generation (IIDG) to a controlled current source alters the passive linear characteristics of power grid’s power frequency fault component (PFFC) network. This transformation undermines the theoretical foundation of power frequency superimposed distance protection (PFSDP) and potentially degrades its performance. To address this issue, this article investigates the mechanism behind the degraded sensitivity of PFSDP installed at IIDG side by analyzing the PFFC sequence component voltages during faults. We then propose control strategies that temporarily restrict the positive-sequence current output of the IIDG during faults while permitting negative-sequence current injection into the grid. This approach achieves two objectives: 1) mitigating the adverse effects of positive-sequence current output by the IIDG on PFSDP; and 2) enabling PFSDP’s reliable operation by leveraging negative-sequence PFFC current. Simulations and tests demonstrate that the proposed strategies effectively improve the sensitivity and reliability of PFSDP in inverter-dominated grids.


  • Open Access

    Protection Scheme for Distribution Network Ground Fault Based on Comparison of Zero Sequence Magnitude

    by Shaofan Zhang, Yanchun Cai, Yanhong Li, Hongliang Wu, Ze Li, Zhengtian Li

    In view of the increasingly complex structure of the distribution network and the deterioration of the existing zero-sequence current protection due to the access of distributed power sources, this paper proposes a new protection scheme for single-phase grounding faults in the distribution network by using the widespread configuration of the first and second deep fusion switches in the distribution network, which makes it easy to measure the zero-sequence voltage and zero-sequence current directly, and the real-time data transmission brought by 5G communication technology. The following new protection scheme is proposed: with the help of 5G communication network, the zero-sequence voltage amplitude and line zero-sequence current amplitude of each bus node measured by the first and second depth fusion switches are transmitted to the intelligent protection center, which locates the faulty line and issues commands to isolate it from the fault. The scheme uses the magnitude information of the zero sequence electrical quantities after the fault and does not depend on strict data synchronization. As verified by PSCAD/EMTDC simulation, the scheme improves the reliability and resistance to transition resistance of traditional zero sequence current protection, and can selectively achieve fault isolation even in the case of communication abnormalities resulting in partial information loss, which has good engineering application value.


  • A Novel Single-Ended Transient-Based Boundary Protection Scheme for 35 kV Active Distribution Networks Based on Capacitive Voltage Transformers

    by Yuqi Wu, Zhengtian Li, Xiangning Lin, Zhongnan Feng, Shankang Cao, Fanrong Wei

    When many distributed generators (DGs) are connected to active distribution networks (ADNs), the performance of conventional overcurrent protection can seriously deteriorate. In response, single-ended transient-based boundary protection is considered an effective scheme for improving relay performance in ADNs due to its independence from power supply properties and its ability to cover an entire protected feeder. However, this approach depends on the filtering effect of the line boundary. This paper finds that capacitive voltage transformers (CVTs), metal-oxide arresters (MOAs), and the stray capacitances of the other apparatuses can serve together as line boundaries at substations and switching stations, and their excellent high-frequency filtering characteristics can assist in boundary protection design. A protection criterion is constructed based on the differences in high-frequency spectral energy between the internal and external fault-generated traveling waves (TWs). Furthermore, a novel two-stage boundary protection scheme is formed by reasonably coordinating the operation sequence and the protection scope of the first- and second-stage boundary protection. Finally, based on the PSCAD platform, the effectiveness, sensitivity, and reliability of the proposed protection scheme are verified under different fault scenarios.


  • A Novel Single-Ended Transient-Based Boundary Protection Based on the Instantaneous Energy of Traveling Waves

    by Yuqi Wu, Zhengtian Li, Xiangning Lin, Zhongnan Feng, Shankang Cao, Fanrong Wei

    With the development of renewable energy sources, single-ended transient-based boundary protection, unaffected by the characteristics of electronic devices, has regained public attention. However, some issues remain: 1) due to the elimination of line traps, the line boundary characteristics relying solely on the bus stray capacitance are unclear; 2) conventional boundary protection has insufficient sensitivity to fault type, fault inception angle, fault resistance, and number of transmission lines; and 3) the internal faults and the remote bus faults cannot be reliably distinguished. Therefore, this paper presents a novel boundary protection scheme for a 220 kV transmission system. First, the transient model of the bus system is established, confirming that the line boundary without line traps still has a remarkable attenuating effect on high-frequency transients. Then, based on the Teager energy operator, a novel protection criterion with sufficient sensitivity is constructed by utilizing the high- to low-frequency instantaneous energy ratio of fault-generated traveling waves (TWs). Furthermore, remedial reclosing measures without the communication channel are proposed to address remote bus faults effectively. Finally, based on PSCAD software, the excellent performance of the proposed approach is verified in a renewable power system.


  • Dynamics Islanding Control for Power Grid With High Penetration of Renewable Energy

    by Yi Jiang, Xiangning Lin, Fanrong Wei, Hanli Weng, Zhengtian Li, Shankang Cao, Yuqi Wu

    Out-of-step (OOS) oscillation is a key link in the power system outage evolution. Precise islanding control can prevent system outages. Renewable energy is connected to the power grid through transverter. From a system construction perspective, it can be regarded as grid-following sources. A large number of inverters lead to more dynamic instability characteristics in the power system, affecting the reliability of existing island control. In this article, the model of oscillation in system with renewable energy is simplified based on the control objective of the converter. The change in OOS oscillation characteristics is analyzed, caused by energy fluctuations. The results show that energy fluctuations during OOS oscillations may affect rotor angle stability and cause the center of oscillation to migrate dynamically over a wide range. This article proposes an islanding control method based on power flow. It only requires dispatchers to obtain power flow information to accurately predict the trend of system instability and dynamically track the center of oscillation. The judgment results can serve as criteria for dealing with the problem of when and where to split the power system. The proposed method has been tested on the IEEE testing system.


  • Coordinated Control for Islanded DC Microgrid Based on Derivative of Bus Voltage

    by Shankang Cao, Fanrong Wei, Yuqi Wu, Xiangning Lin, Zhengtian Li

    The unbalanced power generated by unintentional islanding is a tremendous challenge to the stable operation of the DC microgrid. When dealing with this challenge, the existing communication-free voltage-threshold-based coordinated control lags far behind the actual power variation, which exacerbates the risk of voltage violations in the microgrid. To address the drawback of the existing control, this paper proposes a new method based on the derivative of bus voltage. Firstly, based on the mathematical correlation between unbalanced power and the derivative of bus voltage, a coordination control strategy and its switching criterion before the battery energy storage system (BESS) exits operation is proposed. Meanwhile, we propose a communication-free approach to sense the operation state of the BESS based on the dynamic process of the derivative of bus voltage. Thus the information obtained under complicated circumstances could be further enriched. Subsequently, a new control strategy after BESS operates operation is established to coordinate different sources among the microgrid. Compared with the existing coordinated control methods, the proposed one can better utilize the information contained in the dynamic process of the bus voltage. Numerical results validate the effectiveness and advantages of the proposed method.


  • Novel Source-Storage Coordination Strategy Adaptive to Impulsive Generation Characteristic Suitable for Isolated Island Microgrid Scheduling

    by Zhongnan Feng, Fanrong Wei, Chuantao Wu, Quan Sui, Xiangning Lin, Zhengtian Li

    Wave energy generator (WEG) is a new renewable energy source with prominent advantages and disadvantages. Theoretically, it can move around the sea to harvest wave energy better and will not take up valuable land resources. Normally, WEG collects tiny wave energy continuously and generates electricity intermittently on the minute time-scale to enhance energy harvesting efficiency. Thus, the output of WEG shows prominent impulsive characteristics, which needs to be compensated by the battery energy storage system (BESS) and therefore brings about significant battery life losses. For the purpose of stable and economic operation of the weak power grid connected by WEG, a flexible control method enabling a quantifiable tradeoff between its energy harvesting efficiency and impulsive characteristics is proposed. Then, a novel source-storage coordination strategy and the corresponding energy exchange model of WEG with several optimizable control parameters is formulated to depict the energy flow within the microgrid. Subsequently, an optimization algorithm is proposed to schedule the WEG’s mobile route and optimizable control parameters simultaneously. Simulation results show that the proposed source-storage strategy and the energy management scheme can balance WEG’s energy harvesting and impulsive impact, and utilize its mobility to improve the isolated island microgrid’s operation economy and power quality.


  • Self-Sustaining of Post-Disaster Pelagic Island Energy Systems With Mobile Multi-Energy Storages

    by Quan Sui, Fanrong Wei, Chuantao Wu, Xiangning Lin, Zhengtian Li

    Extreme natural hazards may damage the pelagic island energy system (PIES) integrating distribution systems, cold storages and desalination stations, resulting in the electric service interruption, stored food deterioration, and freshwater shortage. To alleviate the energy demand of residents as much as possible before the arrival of mainland emergency resources, a novel self-sustaining strategy of post-disaster PIESs with mobile multi-energy storages is proposed in this paper. First, mobile multi-energy storages are used to delivery electricity, ice, and water among stations to increase the resource supply resilience. Their differences in resource delivery time and transportation energy consumption are modelled. On this basis, mobile multi-energy storages are coordinated with diesel generators, cold storages, desalination devices, network reconfiguration, and islanded grid merging for self-sustaining of post-disaster PIESs. The utility loss evaluation model of the common electric load shedding, food deterioration, and freshwater shortage is established, in order to better reflect and respond to the needs of residents. Robust optimization methods are also used to address the uncertainties of the renewable generation, multi-type load demand, and especially energy transmission (i.e., traffic congestion time and line repair time), making the restoration strategy reliable. Finally, case studies verified the superiority of the proposed strategy.