NJNeng Jin

Neng Jin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Neng Jin has a total of 30 co-authors. Here are the top co-authors by number of shared publications:

  • Zhengtian Li

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, China

    10 shared publications
  • Xiangning Lin

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, China

    6 shared publications
  • Le Chen

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, China

    5 shared publications
  • Zirui Rong

    State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, China

    5 shared publications
  • Xiangning Lin

    School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China

    4 shared publications
  • Ning Tong

    School of Automation, Guangdong University of Technology, Guangzhou 510006, China

    3 shared publications

Latest Publications

  • Open Access

    A Novel DC Bias Suppression Method Considering the Cooperation of Multiple Devices

    by Shumin Ma, Xiangning Lin, Zhengtian Li, Neng Jin, Zirui Rong, Peifu Zhang, Haibo Xu

    The dc bias phenomenon caused by the excessive current of the neutral point will pose significant threats to the transformers. The conventional suppression method based on capacitive dc blocking device (BD) can prevent dc bias current from penetrating the transformer winding and is the most widely used. However, due to the high investment cost of the BD, it is not appropriate to install the BD for all transformers around the grounding electrode. Thus the BD may redirect the dc flow from one transformer with a BD to the peripheral transformers without BDs, causing the neutral current to exceed undesirably. To address the problems above, a new type of current balancing device (CBD) is introduced, which can lead to flexible suppression of neutral current. Based on coordination between the BD and CBD, a global optimization configuration method is proposed. Unlike the existing suppression strategy based on dc bias suppression devices, the proposed method optimizes the configuration of suppression devices for each transformer from a global perspective in the planning stage, which is an effective supplement to the current suppression method. MATLAB-based simulation results verify the effectiveness and superiority of the proposed method by numerous comparative case studies.


  • Open Access

    A System-Level Suppression Method for DC Bias Based on Reverse Unbalanced Currents in the Same Transmission Section

    by Shumin Ma, Xiangning Lin, Zhengtian Li, Neng Jin, Zirui Rong, Peifu Zhang, Haibo Xu

    Conventional dc bias suppression strategies mainly rely on a single type of device, such as blocking capacitor or blocking resistance. However, these methods are passive palliatives and cannot restrain dc bias currents from the sources. In the light of this, a system-level suppression method for dc bias is proposed in this paper. The average value of currents flowing through the earth is offset by actively generating unbalanced current through other dc projects in the same transmission section, which will reduce the currents flowing into the neutral transformers and alleviate the negative impacts of dc bias. First, the feasibility of the same section dc continuous power support is analyzed. Then the dc bias suppression strategy based on reverse unbalanced currents is elaborated. By scanning all the theoretical operable solutions of unbalanced current generation modes and the possible switching combinations of blocking capacitors, the optimal dc bias suppression solution is output considering the number of adjusted dc projects, the overload margin of dc projects and neutral dc currents of transformers. The effectiveness and superiority of the proposed method are verified by comparative case studies of the East China power grid.


  • Countermeasure on Preventing Line Zero-Sequence Overcurrent Protection From Mal-Operation Due to Magnetizing Inrush

    by Neng Jin, Jiawei Xing, Xiangning Lin, Peifu Zhang, Zirui Rong, Ning Tong, Le Chen, Zhengtian Li

    With the capability of limiting the increasing short-circuit current of power grid, high voltage built-in high-impedance transformer has been widely used in recent years. However, due to its special structure, the magnetizing inrush with high magnitude and slow decay is likely to occur during no-load energization, which may lead to the mal-operation of zero-sequence overcurrent protection of the upstream transmission line. This phenomenon has become a serious problem in the actual production in China. To solve this problem, a modified time difference method is proposed based on the substation area information, so as to accurately identify the magnetizing inrush, internal fault as well as current transformer saturation. Subsequently, a countermeasure on preventing line zero-sequence overcurrent protection from mal-operation due to HV built-in high-impedance transformer energization is proposed. Simulation results based on PSCAD indicate that the proposed protection scheme can cope with various kinds of energization and fault situations effectively. Thus, the correct operation of zero-sequence overcurrent protection can be ensured. Compared with other existing identification methods of magnetizing inrush, the proposed method shows great superiority.


  • Coordinated Sequential Control of Individual Generators for Large-Scale DFIG-Based Wind Farms

    by Ning Tong, Xiangning Lin, Zhengtian Li, Jiakun Fang, Yixin Zhuo, Quan Sui, Neng Jin, Zhe Chen, Namig Muradov

    To enhance the Low-voltage Ride Through (LVRT) capability of large-scale centralized wind farms is essential for the safety of the wind farm and the security of the power system. However, the LVRT capability enhancement coordinating the control and protection of individual wind generators merits consideration. To contribute in this way, a Coordinated Sequential Control (CSC) strategy is proposed in this manuscript. Regarding different voltage disturbance scenarios, the goal of voltage control is determined in real-time. To keep as many wind turbines operating grid-connected as possible, a multi-staged coordination strategy is set according to the critical time to ride through the fault. The reactive power control and the shedding of the wind turbines are coordinated in the three stages of the CSC. According to the simulation results, more wind turbines can be kept grid-connected by using the proposed control strategy. Comparison studies are made among several types of coordinating strategies, emphasizing the advantages of the proposed method in terms of both validation and real-time performance.


  • Phase-Space-Based Pilot Main Protection for a Transmission Line Immune to Timing Attack and Controllable Shunt Reactors

    by Neng Jin, Xiangning Lin, Zirui Rong, Jiawei Xing, Le Chen, Zhengtian Li, Peifu Zhang, Ning Tong, Xiao Ma

    Pilot current differential protection for transmission lines is an important part of ensuring the safety of the power grid. The loss of data synchronization due to cyberattacks and the uncertain compensation degree of controllable shunt reactors will evidently deteriorate the performance of pilot current differential protection and may lead to the maloperation of the protection if no effective countermeasure is implemented. To address the above problems, a novel line pilot protection criterion based on the recognition of the phase space trajectory is proposed. First, the basic principle of phase space and its parameter selection scheme are analyzed. Then, the fault component instantaneous power difference (FCIPD) is selected as the time series for phase space reconstruction, and the distribution characteristics of the phase space trajectory of the FCIPD under different conditions are analyzed. Subsequently, a novel pilot main protection criterion for a transmission line is proposed. PSCAD/EMTDC-based simulation results verify that the proposed criterion is immune to timing attack and controllable shunt reactors and has the advantages of free setting, high speed and high-fault-resistance tolerance capability.


  • Local Measurement-Based Ultra-High-Speed Main Protection for Long Distance VSC-MTDC

    by Ning Tong, Xiangning Lin, Yan Li, Zhihao Hu, Neng Jin, Fanrong Wei, Zhengtian Li

    To ensure the continuous operation of the VSC-MTDC, there has been much concern regarding how to isolate the single-pole earth fault by means of protective relaying. However, when the boundary components are not on the DC transmission lines, conventional main protections for the HVDC systems perform less satisfactorily. To solve this problem, a local measure-ment-based ultra-high-speed main protection is proposed in this manuscript. The proposed method is achieved by the co-operation of the single-end directional start-up criterion and the surge arrival time difference between the 0-mode and 1-mode traveling waves. According to the simulation results, the proposed method has satisfactory performance against internal faults and is quite reliable in external fault and operating condi-tion changes. Meanwhile, the reach is also wide enough to cover most of the protected line. Comparison studies are also con-ducted among the proposed protection and three types of exist-ing protection schemes, highlighting the advantages of the pro-posed protection in terms of selectivity, operating speed and resistive tolerance.


  • Research on Multiterminal Current Differential Protection Criterion With High Sensitivity and Synchronization Error Tolerance Capability

    by Neng Jin, Xiangning Lin, Jiawei Xing, Zhengtian Li, Shiming Liu, Le Chen, Xiao Ma, Zirui Rong, Ning Tong

    As the most suitable main protection for multi-terminal transmission lines represented by T-connections, current differential protection exhibits great performance due to its high reliability and sensitivity. However, considering multiple substations geographically, there are more severe problems of data synchronization for multi-terminal current differential protection than for double-terminal types based on a typical channel. To solve the aforementioned problems, the operating characteristics of multi-terminal line differential protection under different synchronization errors on the - plane are first analyzed. Based on the influence of synchronization errors on the magnitude and phase of the protection operating value, a design method for the restraint current of multi-terminal current differential protection is proposed. To achieve the sensitivity of a high resistance internal fault, as well as the tolerance capability of the data phase-shift error, double restraint coefficients are introduced to optimize the shape and area of the restraint region. Subsequently, the setting method is inferred, which can be used as a reference for an engineering application and the promotion of multi-terminal line differential protection. Finally, the simulation results indicate that the proposed method can significantly improve the criterion security for the case of additional data synchronization errors while maintaining the sensitivity of the internal fault.


  • Remedial Pilot Main Protection Scheme for Transmission Line Independent of Data Synchronism

    by Le Chen, Xiangning Lin, Zhengtian Li, Fanrong Wei, Neng Jin, Ran Lyu, Chang Liu

    For those protective relays highly dependent on common centralized timing synchronization, the threat of loss of data synchronism, e.g., due to cyber-attack, cannot be ignored. In this case, measurements could be falsely timestamped, leading to undesired mal-operation of protection or evident performance deterioration if countermeasures are lacking. In this paper, several different timing attack scenarios and impacts to protective relays on the transmission line are analyzed. To cope with the timing attack scene, a remedial pilot main protection scheme based only on modulus information of measurements for a transmission line is proposed, independent of timing information. The proposed remedial scheme includes a modulus summation impedance relay, a mid-part relay and an instantaneous over-current relay. The effectiveness of the proposed scheme has been validated by theoretical analysis and simulation tests.