TKTaro Koya

Taro Koya

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Taro Koya has a total of 81 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Prognostic Value of New Proposed Criteria for Atrial Cardiomyopathy in Patients With Heart Failure

    by Hiroki Uehara, Makoto Kambayashi, Toshiyuki Nagai, Shota Saito, Kosuke Nakamura, Motoki Nakao, Yoshifumi Mizuguchi, Isao Yokota, Taro Koya, Atsushi Tada, et al.


  • Different Effects of Defibrillator Shocks on the Myocardial Damage Between Subcutaneous and Transvenous Implantable Cardioverter‐Defibrillators

    by Takahide Kadosaka, Masaya Watanabe, Motoki Nakao, Taro Koya, Hikaru Hagiwara, Hiroyuki Gibo, Taro Temma, Kazuya Mizukami, Hisashi Yokoshiki, Toshihisa Anzai

    Background: Although the implantable cardioverter defibrillators (ICD) are the only established treatment to prevent sudden cardiac death, previous studies reported that those who receive shock therapies, whether appropriate or inappropriate, have a higher risk of death. However, the difference in the influence of shock therapies between via Transvenous‐ICD (TV‐ICD) and Subcutaneous‐ICD (S‐ICD) has not been adequately examined. We aimed to investigate the influence of shocks on myocardium in patients with TV‐ICD and S‐ICD. Methods: We enrolled consecutive patients who received a defibrillator or transvenous pacemaker (TV‐PM) implantation between November 2020 and March 2024. A total of 74 patients were included in this study and divided into three groups: patients with TV‐ICD with defibrillation testing (DFT) (TV‐DFT, 27 patients), those with transvenous devices implanted without DFT (TV‐no DFT, 25 patients) and those with S‐ICD (22 patients). Results: Delta log troponin‐I (the difference of serum troponin‐I levels between baseline and after implantation) was significantly increased in TV‐DFT group. In patients with TV‐ICD (46 patients), Delta log troponin‐I was significantly correlated with total shock joules. In the multivariable linear regression analysis, a value of total shock joules was independently associated with delta troponin‐I. Conclusion: Elevation of serum troponin‐I was associated with the TV‐ICD shocks and correlated with the total shock energy, but not with S‐ICD shocks. Our results suggest that TV‐ICD shocks are associated with greater myocardial injury compared to S‐ICD shocks, and that total shock energy is an important determinant of the extent of myocardial damage.

  • Local Calcium Chloride Infusion Enhances Acute and Chronic Efficacy of Ventricular Pulsed‐Field Ablation

    by Taro Koya, Ikram U. Haq, Jason A. Tri, Ying Yang, Naoto Otsuka, William H. Sauer, Samuel J. Asirvatham, Duy T. Nguyen

    Background: Pulsed‐field ablation (PFA) offers myocardial selectivity with minimal thermal injury, but depth for ventricular lesions may be insufficient or heterogeneous at clinically tolerable field strengths. Calcium electroporation—local calcium chloride (CaCl₂) infusion after PFA—may amplify electroporation‐mediated cell death while maintaining low energy settings. Objective: To determine whether immediate post‐PFA CaCl₂ infusion enhances acute and chronic ventricular lesion formation in vivo. Methods: Nine swine underwent focal ventricular PFA (750–1000 V, biphasic, 20 μs × 50 pulses, 200 ms interpulse) via an irrigated focal catheter and benchtop electroporator. Immediately post‐PFA, lesions were randomized to saline, 0.2 g Ca, or 0.4 g Ca infused locally through the catheter tip. Acute hearts were explanted for TTC analysis; surviving animals were studied at 7 days for chronic lesion geometry. Results: Among 41 acute lesions (17 control, 12 Ca 0.2 g, 12 Ca 0.4 g), Ca 0.4 g increased dark‐zone depth (3.5 ± 1.4 vs. 2.3 ± 0.8 mm; p = 0.038) and pale‐zone depth (2.6 ± 1.3 vs. 1.3 ± 0.8 mm; p = 0.011) versus control. At 7 days ( n = 33 lesions), Ca 0.4 g produced larger scars than control (width 11.6 ± 2.1 vs. 10.0 ± 1.9 mm; p = 0.027; depth 4.2 ± 1 vs. 3.0 ± 0.8 mm; p < 0.001; volume 193.6.4 ± 82.3 vs. 109.4 ± 48.2 mm³; p = 0.001). Conclusions: Local CaCl₂ infusion after ventricular PFA significantly augments acute electroporation effect and chronic lesion size at low output, supporting facilitated PFA as a strategy for deeper, more durable ventricular ablation.


  • Early and Late Myocardial Effects of Proton Beam Cardiac Radioablation

    by Tatsuhiko Hirao, Masayoshi Suda, Maryam E. Rettmann, Amanda J. Deisher, John A. Wight, Taro Koya, Laura K. Newman, Tamar Tchkonia, Jon J. Kruse, Dean A. Shumway, et al.


  • Open Access

    Impact of Statement-Concordant Implantable Cardioverter-Defibrillator Programming on Therapy Reduction in an Asian Cohort

    by Jiro Koya, Taro Temma, Kei Kawakami, Masahiro Kawasaki, Kintaro Shimano, Shota Saito, Daishiro Tatsuta, Kotaro Nishino, Takahide Kadosaka, Taro Koya, et al.

  • Open Access

    Clinical Phenotyping and Treatment Response in Patients With Chronic Heart Failure

    by Daishiro Tatsuta, Motoki Nakao, Toshiyuki Nagai, Yoshifumi Mizuguchi, Isao Yokota, Taro Koya, Atsushi Tada, Suguru Ishizaka, Fusako George, Yoshiya Kato, et al.


  • Characteristics of In Vivo Lesion Formation With a Temperature-Controlled Diamond-Tip Radiofrequency Ablation Catheter in the Ventricle: A Preclinical Model

    by Tatsuhiko Hirao, Maryam E. Rettmann, Megan M. Schmidt, Omar Z. Yasin, Gurukripa N. Kowlgi, Naoto Otsuka, Taro Koya, Laura K. Newman, Douglas L. Packer, Konstantinos C. Siontis

    BACKGROUND: Power-controlled radiofrequency ablation with irrigated-tip catheters has been the norm for ventricular ablation for almost 2 decades. New catheter technology has recently integrated more accurate tissue temperature sensing enabling temperature-controlled irrigated ablation. We aimed to investigate the in vivo ablation parameters and lesion formation characteristics in ventricular myocardium using a novel temperature-controlled radiofrequency catheter. METHODS: Twenty canines were divided into 3 groups: 4 noninfarcted, acute (phase I); 8 noninfarcted, chronic (phase II); and 8 infarcted, chronic (phase III). Lesions were delivered with a temperature-controlled radiofrequency system utilizing a chemical vapor deposit diamond for efficient thermal diffusivity. In phase I, 17 ablation settings were tested (temperature set points, 50/60/70 °C; ablation duration, 15/30/60/90/120 s; and power limit, 30/50 W). Four and one of these sets of parameters were further tested in phases II and III, respectively. Lesions were assessed by ex vivo contrast-enhanced magnetic resonance imaging and gross pathology 5 weeks after ablation in phases II/III. RESULTS: Across all phases, 111 ablation lesions were delivered. Ablation with the power limit of 50 W, the temperature set point of 60 °C, and the duration of 60 s produced significantly larger and deeper lesions (mean, 569.2 mm 3 ; mean maximal depth, 9.8 mm) compared with 50 W/60 °C/30 s (mean, 340.4 mm 3 ; mean maximal depth, 8.3 mm) and 50 W/50 °C/60 s (mean, 227 mm 3 ; mean maximal depth, 6.9 mm), with P <0.05 for all pairwise comparisons. Ablation of infarcted myocardium in phase III (50 W/60 °C/30 s) resulted in smaller impedance and bipolar electrogram amplitude changes and lesion size compared with ablation in normal myocardium with the same settings. No steam pop, myocardial perforation, or char formation was observed in any of the 111 ablations across all phases. CONCLUSIONS: In vivo radiofrequency ablation in a canine model with a diamond-tip temperature-controlled catheter using a temperature set point of 60 °C and a power limit of 50 W created large lesions without steam pop risk in both normal and infarcted ventricular myocardia.


  • Normalization of increasing shocking coil impedance with full output synchronized shock

    by Takahide Kadosaka, Masaya Watanabe, Motoki Nakao, Taro Koya, Taro Temma, Toshihisa Anzai

    Introduction: Impedance is a crucial parameter in cardiovascular implantable electronic devices (CIEDs). Clinically, most CIEDs measure impedance using low voltage sub‐threshold measurement (LVSM). Although the LVSM of shock impedance (LVSM‐SI) is generally comparable with high voltage shock impedance (HVSI), LVSM‐SI might be inaccurate if peri‐lead tissue degeneration occurs.Methods and Results: We present a case of elevated LVSM‐SI occurring 8 years post‐lead implantation, possibly attributed to encapsulation of the right ventricular lead coil. After 0.1 J shock was delivered, a full output synchronized shock was administered to measure HVSI, revealing a normal value. Furthermore, LVSM‐SI was normalized and maintained within the normal range during long‐term follow‐up.Conclusion: Our findings suggest conducting a full‐output synchronized shock test to assess HVSI when abnormal LVSM‐SI is detected in the remote phase post‐ICD implantation, which may be considered to help normalize LVSM shock impedance.


  • Empagliflozin attenuates arrhythmogenesis in diabetic cardiomyopathy by normalizing intracellular Ca2+ handling in ventricular cardiomyocytes

    by Takahide Kadosaka, Masaya Watanabe, Hiroyuki Natsui, Takuya Koizumi, Motoki Nakao, Taro Koya, Hikaru Hagiwara, Rui Kamada, Taro Temma, Fuyuki Karube, et al.

    SGLT2is are known to improve cardiovascular outcomes regardless of the presence of diabetes and decrease traditional cardiovascular risk factors. We demonstrated, for the first time, that EMPA inhibited PVCs by normalizing Ca2+ handling in diabetic mice. Our data suggest that the effects of SGLT2is on calcium handling may occur because of suppression of O-GlcNAcylation through inhibition of glucose uptake and not because of NHE inhibition, as previously suggested.


  • Pharmacological nNOS inhibition modified small-conductance Ca2+-activated K+ channel without altering Ca2+ dynamics

    by Taro Koya, Masaya Watanabe, Hiroyuki Natsui, Takahide Kadosaka, Takuya Koizumi, Motoki Nakao, Hikaru Hagiwara, Rui Kamada, Taro Temma, Toshihisa Anzai

    We demonstrated that pharmacological nNOS inhibition increased the atrial arrhythmia inducibility and a specific small-conductance Ca2+-activated K+ channel blocker, apamin, reversed the enhanced atrial arrhythmia inducibility. Apamin mitigated APD abbreviation without alteration of Ca2+ transient, implying an underlying mechanism of posttranslational modification of SK channels.