Yasuko Yamada Maruo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yasuko Yamada Maruo has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Katsuyuki Izumi
Faculty of Sciences and Engineering, Toyo University, 2100 Kujirai, Kawagoe City, Saitama 350-8585, Japan
2 shared publicationsNaoto Kawamura
Tohoku Institute of Technology, 35-1 Yagiyama Kasumi-cho, Taihakuku, Sendai, Miyagi, 982-8577, Japan
2 shared publicationsNatsumi Abe
Tohoku Institute of Technology, 35-1 Yagiyama Kasumi-cho, Taihakuku, Sendai, Miyagi, 982-8577, Japan
2 shared publicationsAkihiro Karashima
Tohoku Institute of Technology, 35-1 Yagiyama Kasumi-cho, Taihakuku, Sendai, Miyagi 982-8577, Japan
1 shared publication- Akihiro Karashima
Graduate School of Engineering, Tohoku Institute of Technology, 35-1 Yagiyamakasumicho, Taihaku-ku, Sendai 982-8577, Miyagi, Japan
1 shared publication Haruko Suzuki
University of Agriculture and Technology
1 shared publication
Latest Publications
- Open Access
- 8 April 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (4) , 136
Small Acetone Sensor with a Porous Colorimetric Chip for Breath Acetone Detection Using the Flow–Stop Method
Acetone is a well-known biogas involved in lipid metabolism and is considered a potential biomarker for diabetes. However, the conventional detection methods for acetone face the limitations of large size, complex usage, and cross-sensitivity. In this study, we developed a portable device comprising a porous colorimetric acetone analytical chip composed of 2-nitrophenyl hydrazine and porous glass. The analytical chip was highly sensitive and selective for acetone because it was based on the chemical reaction between acetone and hydrazine in a nanoporous material, which provides a large surface area. The device consisted of a 450 nm laser light source and a photodiode detector with a volume of less than 40 mL. Acetone gas was measured in the atmosphere for 10 min using the developed flow–stop method. The measurable acetone concentration ranged from 0 to 6.0 ppm with a detection limit of 0.22 ppm. We successfully conducted a feasibility study using human exhaled breath and analyzed the relationship between exercise and the acetone concentration in the breath. An upward trend in exhaled acetone levels was seen post-exercise for each individual.
- 8 April 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (4) , 136
Open AccessSmall Acetone Sensor with a Porous Colorimetric Chip for Breath Acetone Detection Using the Flow–Stop Method
Acetone is a well-known biogas involved in lipid metabolism and is considered a potential biomarker for diabetes. However, the conventional detection methods for acetone face the limitations of large size, complex usage, and cross-sensitivity. In this study, we developed a portable device comprising a porous colorimetric acetone analytical chip composed of 2-nitrophenyl hydrazine and porous glass. The analytical chip was highly sensitive and selective for acetone because it was based on the chemical reaction between acetone and hydrazine in a nanoporous material, which provides a large surface area. The device consisted of a 450 nm laser light source and a photodiode detector with a volume of less than 40 mL. Acetone gas was measured in the atmosphere for 10 min using the developed flow–stop method. The measurable acetone concentration ranged from 0 to 6.0 ppm with a detection limit of 0.22 ppm. We successfully conducted a feasibility study using human exhaled breath and analyzed the relationship between exercise and the acetone concentration in the breath. An upward trend in exhaled acetone levels was seen post-exercise for each individual.
- 21 January 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (2) , 1023-1031
Disulfide Compound-Impregnated Paper Substrate-Based Highly Efficient Colorimetric Gas Sensor for Detection of Volatile Sulfur Compounds in Noninvasive Breath Analysis
Volatile sulfur compounds (VSCs) are prevalent human biogases detectable in individuals with periodontal disease; therefore, measuring VSC gases in human breath can yield significant, noninvasive diagnostic information indicative of such diseases. In this study, we developed a gas sensor with selective and enhanced sensing capabilities for VSCs methyl mercaptan and hydrogen sulfide. This sensor comprises a cellulose paper substrate impregnated with 2,2'-dithiobis(5-nitropyridine) and sodium acetate. Upon exposure to VSC gases, the initially white sensor element was reversibly changed to yellow. A peak in the diffused reflectance spectrum was noted at 420 nm, establishing a linear relationship between the Kubelka-Munk (K-M) values at 420 nm and the VSC exposure concentration. The sensor demonstrated high sensitivity to methyl mercaptan and hydrogen sulfide with detection limits of 45 and 7.1 ppb in a 1 L volume, respectively. Furthermore, colorimetric analysis of the sensor element images indicated a negative correlation between the K-M value at 420 nm and the B/R value, enabling the calculation of VSC concentration based on the sensor's color change. The cost-effective paper-based sensor simplifies implementation in clinical applications and provides an assay ideally suited for point-of-care.
- 21 January 2025
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 10 (2) , 1023-1031
Disulfide Compound-Impregnated Paper Substrate-Based Highly Efficient Colorimetric Gas Sensor for Detection of Volatile Sulfur Compounds in Noninvasive Breath Analysis
Volatile sulfur compounds (VSCs) are prevalent human biogases detectable in individuals with periodontal disease; therefore, measuring VSC gases in human breath can yield significant, noninvasive diagnostic information indicative of such diseases. In this study, we developed a gas sensor with selective and enhanced sensing capabilities for VSCs methyl mercaptan and hydrogen sulfide. This sensor comprises a cellulose paper substrate impregnated with 2,2'-dithiobis(5-nitropyridine) and sodium acetate. Upon exposure to VSC gases, the initially white sensor element was reversibly changed to yellow. A peak in the diffused reflectance spectrum was noted at 420 nm, establishing a linear relationship between the Kubelka-Munk (K-M) values at 420 nm and the VSC exposure concentration. The sensor demonstrated high sensitivity to methyl mercaptan and hydrogen sulfide with detection limits of 45 and 7.1 ppb in a 1 L volume, respectively. Furthermore, colorimetric analysis of the sensor element images indicated a negative correlation between the K-M value at 420 nm and the B/R value, enabling the calculation of VSC concentration based on the sensor's color change. The cost-effective paper-based sensor simplifies implementation in clinical applications and provides an assay ideally suited for point-of-care.
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Development of a Sensor Element for Detecting Nonanal Using Reaction with Pararosaniline in Porous Glass
Nonanal is a human biogas that can be detected in the breath of patients with lung cancer. Measurement of nonanal gas in human breath provides significant, non-invasive, diagnostic information for signs of lung cancer. In this study, a sensor element for detecting nonanal was developed that composed of porous glass impregnated with pararosaniline and acid (acetic acid with small amount of phosphoric acid). The sensor element, which was initially red, turned violet after exposure to nonanal, and an absorption peak at 620 nm was observed. We observed that only a formation reaction occurs in the porous glass, whereas both formation and decomposition reactions occur in solution; therefore, the sensor element works cumulatively. We found a linear relationship between the 620 nm absorbance change in the sensor element and the exposed nonanal concentration. We successfully detected 8−270 ppb of nonanal, which was calculated from the absorbance change at 620 nm, using the developed sensor element for a 24 h exposure time. In addition, the reaction mechanism was proposed based on kinetic analysis, and it was assumed that the diffusion of nonanal molecules into the porous glass is the rate-determining step.
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessDevelopment of a Sensor Element for Detecting Nonanal Using Reaction with Pararosaniline in Porous Glass
Nonanal is a human biogas that can be detected in the breath of patients with lung cancer. Measurement of nonanal gas in human breath provides significant, non-invasive, diagnostic information for signs of lung cancer. In this study, a sensor element for detecting nonanal was developed that composed of porous glass impregnated with pararosaniline and acid (acetic acid with small amount of phosphoric acid). The sensor element, which was initially red, turned violet after exposure to nonanal, and an absorption peak at 620 nm was observed. We observed that only a formation reaction occurs in the porous glass, whereas both formation and decomposition reactions occur in solution; therefore, the sensor element works cumulatively. We found a linear relationship between the 620 nm absorbance change in the sensor element and the exposed nonanal concentration. We successfully detected 8−270 ppb of nonanal, which was calculated from the absorbance change at 620 nm, using the developed sensor element for a 24 h exposure time. In addition, the reaction mechanism was proposed based on kinetic analysis, and it was assumed that the diffusion of nonanal molecules into the porous glass is the rate-determining step.
- 1 December 2019
- Published by Elsevier in Microchemical Journal
- Vol. 151, 104251
Development of an analytical chip for nitrogen monoxide detection using porous glass impregnated with 2-phenyl-4,4,5,5-tetramethylimidazoline-3-oxide-1-oxyl
- 1 December 2019
- Published by Elsevier in Microchemical Journal
- Vol. 151, 104251
Development of an analytical chip for nitrogen monoxide detection using porous glass impregnated with 2-phenyl-4,4,5,5-tetramethylimidazoline-3-oxide-1-oxyl
- 2 September 2015
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 216, 128-133
Colorimetric NOx sensor based on a porous glass-based NO2 sensing chip and a permanganate oxidizer
- 2 September 2015
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 216, 128-133
Colorimetric NOx sensor based on a porous glass-based NO2 sensing chip and a permanganate oxidizer
- 1 January 2004
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 151 (1-4) , 53-70
Formation and Deposition of Ozone in a Red Pine Forest
- 1 January 2004
- Published by Springer Nature in Water, Air, & Soil Pollution
- Vol. 151 (1-4) , 53-70
Formation and Deposition of Ozone in a Red Pine Forest