Tamer Kamel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tamer Kamel has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Asiya Khan
University of Plymouth
2 shared publications - Hafizul Asad
School of Science and Technology, City St George’s, University of London, London EC1V 0HB, UK
2 shared publications - Mohamed Ahmed Moustafa Hassan
Cairo University
2 shared publications - Muhammad Arsal
School of Engineering, Computing and Mathematics, University of Plymouth, Plymouth PL4 8AA, UK
2 shared publications - Nursaid Polater
Department of Electrical and Electronics Engineering, Faculty of Engineering and Architecture, Yozgat Bozok University, Yozgat, Turkey
2 shared publications - Pietro Tricoli
Department of Electronic, Electrical and Systems Engineering, University of Birmingham, Edgbaston Campus, Birmingham B15 2TT, UK
2 shared publications
Latest Publications
- Open Access
A Comprehensive Review of Modeling and Control Techniques of LCC-HVDC and VSC-HVDC Systems
The rapid advancement of power electronic devices has accelerated the widespread adoption of Line-Commutated Converter (LCC) and Voltage Source Converter (VSC) technologies as leading solutions for high-voltage industrial applications. These technologies have become fundamental components of modern high-voltage direct current (HVDC) transmission systems and advanced Industrial Machine-Drive (IMD) systems. This review presents a comprehensive comparison between conventional LCC technology and the more recent VSC technology, highlighting the operational advantages, limitations, and application suitability of each approach. In addition, it provides an in-depth examination of hierarchical control architectures employed in both LCC-HVDC and VSC-HVDC systems. As these systems are increasingly required to operate closer to their performance limits, the implementation of robust and efficient control strategies has become essential for ensuring stability, reliability, and optimal performance. Consequently, a wide range of control techniques has been developed to address the inherent nonlinearities and parameter uncertainties present in power systems. This review evaluates and compares both conventional and advanced control methods, including Proportional–Integral (PI) control, Variable Coefficient PI (V-PI), Fuzzy PI, Self-Tuning Fuzzy PI (STF-PI), Fractional Order PI (FOPI), Variable Coefficient Fractional Order PI (V-FOPI), Adaptive Neuro-Fuzzy Inference Systems (ANFIS), and Model Predictive Control (MPC). Their performance is assessed across a range of operating conditions, with emphasis on dynamic response, robustness, and overall control effectiveness.
Open AccessA Comprehensive Review of Modeling and Control Techniques of LCC-HVDC and VSC-HVDC Systems
The rapid advancement of power electronic devices has accelerated the widespread adoption of Line-Commutated Converter (LCC) and Voltage Source Converter (VSC) technologies as leading solutions for high-voltage industrial applications. These technologies have become fundamental components of modern high-voltage direct current (HVDC) transmission systems and advanced Industrial Machine-Drive (IMD) systems. This review presents a comprehensive comparison between conventional LCC technology and the more recent VSC technology, highlighting the operational advantages, limitations, and application suitability of each approach. In addition, it provides an in-depth examination of hierarchical control architectures employed in both LCC-HVDC and VSC-HVDC systems. As these systems are increasingly required to operate closer to their performance limits, the implementation of robust and efficient control strategies has become essential for ensuring stability, reliability, and optimal performance. Consequently, a wide range of control techniques has been developed to address the inherent nonlinearities and parameter uncertainties present in power systems. This review evaluates and compares both conventional and advanced control methods, including Proportional–Integral (PI) control, Variable Coefficient PI (V-PI), Fuzzy PI, Self-Tuning Fuzzy PI (STF-PI), Fractional Order PI (FOPI), Variable Coefficient Fractional Order PI (V-FOPI), Adaptive Neuro-Fuzzy Inference Systems (ANFIS), and Model Predictive Control (MPC). Their performance is assessed across a range of operating conditions, with emphasis on dynamic response, robustness, and overall control effectiveness.
- Open Access
- 1 September 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 17 (3) , 1675-1687
FEA-based optimization of switches for reluctance motors
Switched reluctance motors (SRMs) are considered one of the important machines used in industry sectors due to their simple structure, robustness, and high-speed capability. However, the performance is often limited by high torque ripple and acoustic noise due to the uneven magnetic flux distribution. This paper presents an optimization study for improving flux distribution by shape design modifications of the stator and rotor geometry using finite element analysis (FEA) combined with the whale optimization algorithm (WOA). More specifically, FEA is utilized to calculate the magnetic field behavior, torque characteristics, and core losses for different structural geometries of the proposed design, while WOA systematically searches for the optimum values of shape parameters. Thus, the simulation results show that the proposed approach significantly improves the uniformity of flux distribution, hence reducing torque ripple and improving the efficiency. The integration of FEA with the WOA provides a practical and effective way to achieve better SRM performance without further complication of control algorithms.
- 1 September 2026
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 17 (3) , 1675-1687
Open AccessFEA-based optimization of switches for reluctance motors
Switched reluctance motors (SRMs) are considered one of the important machines used in industry sectors due to their simple structure, robustness, and high-speed capability. However, the performance is often limited by high torque ripple and acoustic noise due to the uneven magnetic flux distribution. This paper presents an optimization study for improving flux distribution by shape design modifications of the stator and rotor geometry using finite element analysis (FEA) combined with the whale optimization algorithm (WOA). More specifically, FEA is utilized to calculate the magnetic field behavior, torque characteristics, and core losses for different structural geometries of the proposed design, while WOA systematically searches for the optimum values of shape parameters. Thus, the simulation results show that the proposed approach significantly improves the uniformity of flux distribution, hence reducing torque ripple and improving the efficiency. The integration of FEA with the WOA provides a practical and effective way to achieve better SRM performance without further complication of control algorithms.
- Open Access
From Ship to Shore: A Review of Vessel‐To‐Grid Bidirectional Charging for Sustainable Maritime Transport
This review examines bidirectional charging technology for marine transport electrification, focusing on vessel‐to‐grid (V2G) systems integration within maritime operations. Unlike prior studies that typically address technological, operational, or policy aspects in isolation, this work provides a cross‐disciplinary and system‐level synthesis of V2G in maritime contexts. It evaluates the technological advancements, economic potential, and environmental benefits that V2G can offer to the marine sector, with an emphasis on cost reduction, emissions control, and energy resilience. By explicitly linking battery systems, power electronics, port infrastructure, operational strategies, and regulatory frameworks, the review highlights critical interdependencies that shape real‐world implementation. Key challenges are identified, such as infrastructure requirements, grid compatibility, and lifecycle management, along with emerging innovations aimed at addressing these barriers. Case studies from maritime businesses illustrate practical applications and market viability, whereas concluding insights identify cross‐sector research gaps and provide an integrated framework for future research and scalable impact in sustainable marine transport.
Open AccessFrom Ship to Shore: A Review of Vessel‐To‐Grid Bidirectional Charging for Sustainable Maritime Transport
This review examines bidirectional charging technology for marine transport electrification, focusing on vessel‐to‐grid (V2G) systems integration within maritime operations. Unlike prior studies that typically address technological, operational, or policy aspects in isolation, this work provides a cross‐disciplinary and system‐level synthesis of V2G in maritime contexts. It evaluates the technological advancements, economic potential, and environmental benefits that V2G can offer to the marine sector, with an emphasis on cost reduction, emissions control, and energy resilience. By explicitly linking battery systems, power electronics, port infrastructure, operational strategies, and regulatory frameworks, the review highlights critical interdependencies that shape real‐world implementation. Key challenges are identified, such as infrastructure requirements, grid compatibility, and lifecycle management, along with emerging innovations aimed at addressing these barriers. Case studies from maritime businesses illustrate practical applications and market viability, whereas concluding insights identify cross‐sector research gaps and provide an integrated framework for future research and scalable impact in sustainable marine transport.
- Open Access
A Systematic Review of Cyber Risk Analysis Approaches for Wind Power Plants
Wind power plants (WPPs), as large-scale cyber–physical systems (CPSs), have become essential to renewable energy generation but are increasingly exposed to cyber threats. Attacks on supervisory control and data acquisition (SCADA) networks can cause cascading physical and economic impacts. The systematic synthesis of cyber risk analysis methods specific to WPPs and cyber–physical energy systems (CPESs) is a need of the hour to identify research gaps and guide the development of resilient protection frameworks. This study employs a Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) protocol to review the state of the art in this area. Peer-reviewed studies published between January 2010 and January 2025 were taken from four major journals using a structured set of nine search queries. After removing duplicates, applying inclusion and exclusion criteria, and screening titles and abstracts, 62 studies were examined for analysis on the basis of a synthesis framework. The studies were classified along three methodological dimensions, qualitative vs. quantitative, model-based vs. data-driven, and informal vs. formal, giving us a unified taxonomy of cyber risk analysis approaches. Among the included studies, 45% appeared to be qualitative or semi-quantitative frameworks such as STRIDE, DREAD, or MITRE ATT&CK; 35% were classified as quantitative or model-based techniques such as Bayesian networks, Markov decision processes, and Petri nets; and 20% adopted data-driven or hybrid AI/ML methods. Only 28% implemented formal verification, and fewer than 10% explicitly linked cyber vulnerabilities to safety consequences. Key research gaps include limited integration of safety–security interdependencies, scarce operational datasets, and inadequate modelling of environmental factors in WPPs. This systematic review highlights a predominance of qualitative approaches and a shortage of data-driven and formally verified frameworks for WPP cybersecurity. Future research should prioritise hybrid methods that integrate formal modelling, synthetic data generation, and machine learning-based risk prioritisation to enhance resilience and operational safety of renewable-energy infrastructures.
Open AccessA Systematic Review of Cyber Risk Analysis Approaches for Wind Power Plants
Wind power plants (WPPs), as large-scale cyber–physical systems (CPSs), have become essential to renewable energy generation but are increasingly exposed to cyber threats. Attacks on supervisory control and data acquisition (SCADA) networks can cause cascading physical and economic impacts. The systematic synthesis of cyber risk analysis methods specific to WPPs and cyber–physical energy systems (CPESs) is a need of the hour to identify research gaps and guide the development of resilient protection frameworks. This study employs a Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) protocol to review the state of the art in this area. Peer-reviewed studies published between January 2010 and January 2025 were taken from four major journals using a structured set of nine search queries. After removing duplicates, applying inclusion and exclusion criteria, and screening titles and abstracts, 62 studies were examined for analysis on the basis of a synthesis framework. The studies were classified along three methodological dimensions, qualitative vs. quantitative, model-based vs. data-driven, and informal vs. formal, giving us a unified taxonomy of cyber risk analysis approaches. Among the included studies, 45% appeared to be qualitative or semi-quantitative frameworks such as STRIDE, DREAD, or MITRE ATT&CK; 35% were classified as quantitative or model-based techniques such as Bayesian networks, Markov decision processes, and Petri nets; and 20% adopted data-driven or hybrid AI/ML methods. Only 28% implemented formal verification, and fewer than 10% explicitly linked cyber vulnerabilities to safety consequences. Key research gaps include limited integration of safety–security interdependencies, scarce operational datasets, and inadequate modelling of environmental factors in WPPs. This systematic review highlights a predominance of qualitative approaches and a shortage of data-driven and formally verified frameworks for WPP cybersecurity. Future research should prioritise hybrid methods that integrate formal modelling, synthetic data generation, and machine learning-based risk prioritisation to enhance resilience and operational safety of renewable-energy infrastructures.
- Open Access
- 1 January 2026
- Published by Tech Science Press in Energy Engineering
- Vol. 123 (4) , 1-10
Experimental Evaluation of the Static and Dynamic Electrical Parameters of the Solar Panels to Characterize Their Real-Time Performance at Variable Operational Conditions
This study provides a new experimental framework to measure the static and dynamic electrical parameters for a solar panel of multiple cells. The study evaluates its static parameters, including its resultant diodes’ saturation currents, diodes’ ideality factors, series, and shunt resistances. Such parameters are essential to characterise the steady-state performance of a solar panel. Additionally, the dynamic parameters as the equivalent junction and diffusion capacitances are also experimentally measured. These parameters impact the performance of the panel at variable solar irradiance, temperature, and load conditions. A solar panel of 36 series-connected cells has been utilised in this research to undertake this experimental evaluation. This work addresses a gap in the recent literature regarding a full evaluation of the internal electrical parameters in a whole solar panel of multiple cells. Firstly, a dark experimental environment has been developed so that no influence from external light sources can affect the measurements being taken. The panel is then stimulated with different types of electrical stresses in various circuit configurations to measure the required static and dynamic parameters. For the solar panel under study, the series and shunt resistances per cell have been evaluated to be 18.91 mΩ and 5.6 kΩ, respectively, while the junction and diffusion capacitances have shown direct and inverse relationships, respectively, with the applied voltage as expected. The outcomes of these experimental setups highlighted the importance of the developed comprehensive framework in this research to be employed to assess the quality of the solar panel and its real-time performance at variable operational conditions.
- 1 January 2026
- Published by Tech Science Press in Energy Engineering
- Vol. 123 (4) , 1-10
Open AccessExperimental Evaluation of the Static and Dynamic Electrical Parameters of the Solar Panels to Characterize Their Real-Time Performance at Variable Operational Conditions
This study provides a new experimental framework to measure the static and dynamic electrical parameters for a solar panel of multiple cells. The study evaluates its static parameters, including its resultant diodes’ saturation currents, diodes’ ideality factors, series, and shunt resistances. Such parameters are essential to characterise the steady-state performance of a solar panel. Additionally, the dynamic parameters as the equivalent junction and diffusion capacitances are also experimentally measured. These parameters impact the performance of the panel at variable solar irradiance, temperature, and load conditions. A solar panel of 36 series-connected cells has been utilised in this research to undertake this experimental evaluation. This work addresses a gap in the recent literature regarding a full evaluation of the internal electrical parameters in a whole solar panel of multiple cells. Firstly, a dark experimental environment has been developed so that no influence from external light sources can affect the measurements being taken. The panel is then stimulated with different types of electrical stresses in various circuit configurations to measure the required static and dynamic parameters. For the solar panel under study, the series and shunt resistances per cell have been evaluated to be 18.91 mΩ and 5.6 kΩ, respectively, while the junction and diffusion capacitances have shown direct and inverse relationships, respectively, with the applied voltage as expected. The outcomes of these experimental setups highlighted the importance of the developed comprehensive framework in this research to be employed to assess the quality of the solar panel and its real-time performance at variable operational conditions.
- 22 August 2025
- Published by Springer Nature
- p. 340-354
Cyber-Safety Assessment of Wind Turbines: A Reachability Analysis Approach Against Cyber-Attacks
- 22 August 2025
- Published by Springer Nature
- p. 340-354
Cyber-Safety Assessment of Wind Turbines: A Reachability Analysis Approach Against Cyber-Attacks
- Open Access
Real-Time Temperature Estimation of the Machine Drive SiC Modules Consisting of Parallel Chips per Switch for Reliability Modelling and Lifetime Prediction
This paper presents a new methodical procedure to monitor in real time the junction temperature of SiC Power MOSFET modules of parallel-connected chips utilized in machine drive systems to develop their reliability modelling and predict their lifetime. The paper implements the on-line measurements of temperature-sensitive electrical parameters (TSEP) approach, particularly the quasi-threshold voltage and the on-state drain to source voltage, to estimate the junction temperature in real time. The proposed procedure firstly applied computational fluid dynamics analysis on the module under study to determine the chip which undergoes the maximum junction temperature during typical operation of the module. Then, a calibration phase, using double-pulse tests on the selected chip, is used to generate look-up tables to relate the TSEPs under study to the junction temperature. Next, the real-time estimation of junction temperature was accomplished during the on-line operation of the three-phase inverter, taking into account the induced distortion/noises due to operation of the parallel-connected chips in the module. After that, a comparison between the two TSEPs under study was provided to demonstrate their advantages/drawbacks. Finally, reliability modelling was developed to predict the lifetime of the studied module based on the estimated junction temperature under a predetermined mission profile.
Open AccessReal-Time Temperature Estimation of the Machine Drive SiC Modules Consisting of Parallel Chips per Switch for Reliability Modelling and Lifetime Prediction
This paper presents a new methodical procedure to monitor in real time the junction temperature of SiC Power MOSFET modules of parallel-connected chips utilized in machine drive systems to develop their reliability modelling and predict their lifetime. The paper implements the on-line measurements of temperature-sensitive electrical parameters (TSEP) approach, particularly the quasi-threshold voltage and the on-state drain to source voltage, to estimate the junction temperature in real time. The proposed procedure firstly applied computational fluid dynamics analysis on the module under study to determine the chip which undergoes the maximum junction temperature during typical operation of the module. Then, a calibration phase, using double-pulse tests on the selected chip, is used to generate look-up tables to relate the TSEPs under study to the junction temperature. Next, the real-time estimation of junction temperature was accomplished during the on-line operation of the three-phase inverter, taking into account the induced distortion/noises due to operation of the parallel-connected chips in the module. After that, a comparison between the two TSEPs under study was provided to demonstrate their advantages/drawbacks. Finally, reliability modelling was developed to predict the lifetime of the studied module based on the estimated junction temperature under a predetermined mission profile.
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 1298-1312
Practical Demonstration and Novel Optimization Control for a Smart Soft Open Point to Maximize the Synergy Between the DC Metro Line and the LV Distribution Grid
The steady increment in electrical loads often requires expensive and disruptive upgrading of the electrical power supply infrastructure. This can be avoided by synergizing the DC railway networks with local AC grids using soft-open points to transfer the available regenerative braking energy of the trains to the nearby local grid. Besides, a battery energy storage system is integrated into the soft-open point to match the braking events with the grid load power. So that the new developed system effectively decouples both the rail and grid networks. This paper presents a practical study for such novel rail+grid energy management strategy. A 100kW smart soft open point is designed and implemented in this research to experimentally evaluate the new strategy in a lab environment using real rail data. Afterwards, the developed 100 kW prototype is accordingly validated in the real environment at Metro Madrid, Spain. Lastly, a multi-objectives optimization framework is designed for the developed management system to maximize the synergy between both networks. the multi-objectives framework aims to minimize the power losses in both networks, maximizing the profit of selling the harvested rail power to the grid and finally maximize the penetration level of the available renewables power in the grid.
- 20 May 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 1298-1312
Practical Demonstration and Novel Optimization Control for a Smart Soft Open Point to Maximize the Synergy Between the DC Metro Line and the LV Distribution Grid
The steady increment in electrical loads often requires expensive and disruptive upgrading of the electrical power supply infrastructure. This can be avoided by synergizing the DC railway networks with local AC grids using soft-open points to transfer the available regenerative braking energy of the trains to the nearby local grid. Besides, a battery energy storage system is integrated into the soft-open point to match the braking events with the grid load power. So that the new developed system effectively decouples both the rail and grid networks. This paper presents a practical study for such novel rail+grid energy management strategy. A 100kW smart soft open point is designed and implemented in this research to experimentally evaluate the new strategy in a lab environment using real rail data. Afterwards, the developed 100 kW prototype is accordingly validated in the real environment at Metro Madrid, Spain. Lastly, a multi-objectives optimization framework is designed for the developed management system to maximize the synergy between both networks. the multi-objectives framework aims to minimize the power losses in both networks, maximizing the profit of selling the harvested rail power to the grid and finally maximize the penetration level of the available renewables power in the grid.
- Open Access
- 17 February 2023
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 52, 559-576
Development of a smart hybrid drive system with advanced logistics for railway applications
- 17 February 2023
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 52, 559-576
Open AccessDevelopment of a smart hybrid drive system with advanced logistics for railway applications
- Open Access
- 29 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
State of Charge-Based Power Sharing Algorithm for Hydrogen and Battery Cells Supplying Double-Three Phase Permanent Magnet Synchronous Motor
This paper presents a new power sharing algorithm for a hybrid power source of hydrogen fuel cells (HFC) and Li-ion battery cells (LiBC) based on state of charge (SOC) of the LiBC to supply a dual three-phase machine in light railways. HFCs are good energy sources to provide reliable power at a steady rate, while, LiBC have fast dynamics that can respond appropriately to the fast load transients. Double three phase permanent magnet synchronous machines (DTPMSM) have been nominated in this research since they provide high reliability in which the fault-tolerant operation can be implemented. Additionally, they provide lower power losses and harmonic distortion along with higher power density. Accordingly, this paper establishes a new SOC -based power sharing algorithm to employ the two power sources to supply DTPMSM. The average traction demand along with the SOC of the LiBC are used as two main inputs for the proposed approach. The system under study has been modelled and evaluated in the Typhoon HIL real time simulator. Comparative analysis is demonstrated at the end of the paper to validate the proposed algorithm.
- 29 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Open AccessState of Charge-Based Power Sharing Algorithm for Hydrogen and Battery Cells Supplying Double-Three Phase Permanent Magnet Synchronous Motor
This paper presents a new power sharing algorithm for a hybrid power source of hydrogen fuel cells (HFC) and Li-ion battery cells (LiBC) based on state of charge (SOC) of the LiBC to supply a dual three-phase machine in light railways. HFCs are good energy sources to provide reliable power at a steady rate, while, LiBC have fast dynamics that can respond appropriately to the fast load transients. Double three phase permanent magnet synchronous machines (DTPMSM) have been nominated in this research since they provide high reliability in which the fault-tolerant operation can be implemented. Additionally, they provide lower power losses and harmonic distortion along with higher power density. Accordingly, this paper establishes a new SOC -based power sharing algorithm to employ the two power sources to supply DTPMSM. The average traction demand along with the SOC of the LiBC are used as two main inputs for the proposed approach. The system under study has been modelled and evaluated in the Typhoon HIL real time simulator. Comparative analysis is demonstrated at the end of the paper to validate the proposed algorithm.