Zhen-Wei Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhen-Wei Chen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Hailong Li
University of Electronic Science and Technology of China
1 shared publication - Hongtu Cheng
School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
1 shared publication Jin-Zhong Cui
Digital Media Lab, University of Electronic Science and Technology of China, Chengdu, China
1 shared publication- Tingli Yang
School of Civil Engineering and Architecture, Wuhan University of Technology, Wuhan, China
1 shared publication - Xiaoxing Zhang
Hubei University of Technology
1 shared publication - Yangxiaoge Zhang
College of Arts and Sciences, University of San Francisco, San Francisco, CA, USA
1 shared publication
Latest Publications
- 26 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (4) , 1498-1505
Study on Photoacoustic Spectroscopy Detection of CO in Gas Insulation Equipment
The related regulations for electric power industry stipulate that CO gas is an important component to be detected when analyzing the gas composition of SF6 equipment. In this study, based on the photoacoustic spectroscopy technology, the quantitative gas detection of CO is carried out. Firstly, in order to avoid the cross-interference effects of other component gases on photoacoustic spectroscopy detection of CO, the characteristic absorption spectrum of CO in 4291.5 cm-1 (which’s wavelength is 2330.2nm) is determined. Secondly, the non-resonant photoacoustic cell is optimized in this study. After that, designing and building a trace gas photoacoustic spectroscopy detection platform around the developed photoacoustic cell, using the built detection platform to perform photoacoustic spectroscopy detection of the concentration of CO, obtaining photoacoustic signals of different concentrations of CO, the photoacoustic signals increase linearly as the concentration increases. With SF6 as the background gas, the lower detection limit of CO gas reaches 20.5 ppm, and with N2 as the background gas, it reaches 5.6 ppm. After all, the influence mechanism of the background gas on the photoacoustic signal is studied, based on the influence mechanism, the lower detection limit of CO with the background gas of different mixing ratios of SF6/N2 is predicted. The verified experiment is basically consistent with the predicted results, which proves the accuracy of the forecast. This study provides guidance for the engineering application of CO photoacoustic spectroscopy detection in SF6 equipment.
- 26 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 29 (4) , 1498-1505
Study on Photoacoustic Spectroscopy Detection of CO in Gas Insulation Equipment
The related regulations for electric power industry stipulate that CO gas is an important component to be detected when analyzing the gas composition of SF6 equipment. In this study, based on the photoacoustic spectroscopy technology, the quantitative gas detection of CO is carried out. Firstly, in order to avoid the cross-interference effects of other component gases on photoacoustic spectroscopy detection of CO, the characteristic absorption spectrum of CO in 4291.5 cm-1 (which’s wavelength is 2330.2nm) is determined. Secondly, the non-resonant photoacoustic cell is optimized in this study. After that, designing and building a trace gas photoacoustic spectroscopy detection platform around the developed photoacoustic cell, using the built detection platform to perform photoacoustic spectroscopy detection of the concentration of CO, obtaining photoacoustic signals of different concentrations of CO, the photoacoustic signals increase linearly as the concentration increases. With SF6 as the background gas, the lower detection limit of CO gas reaches 20.5 ppm, and with N2 as the background gas, it reaches 5.6 ppm. After all, the influence mechanism of the background gas on the photoacoustic signal is studied, based on the influence mechanism, the lower detection limit of CO with the background gas of different mixing ratios of SF6/N2 is predicted. The verified experiment is basically consistent with the predicted results, which proves the accuracy of the forecast. This study provides guidance for the engineering application of CO photoacoustic spectroscopy detection in SF6 equipment.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 404-407
A design of general medical data adapter based on ISO/IEEE 11073 standards
With the approach of the aging society, collecting medical data of old patients becomes more and more important. Currently, there are a wide range of personal health devices (PHD), however, many of these devices have not been standardized and can't be compatible with the same manager. ISO/IEEE 11073 standard is a popular standard in collecting measurement data. In this paper, we propose a design of an 11073 standard adapter, which can be used as a bridge between the medical devices and the 11073 manager applications. The adapter can collect measurement data from different kinds of and types of medical devices, standard devices and non-standard devices are both fine and convert it into 11073 standard data. Using this adapter will hide the diversity of the means of communication at bottom and simplify the process of collecting standard measurement data.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 404-407
A design of general medical data adapter based on ISO/IEEE 11073 standards
With the approach of the aging society, collecting medical data of old patients becomes more and more important. Currently, there are a wide range of personal health devices (PHD), however, many of these devices have not been standardized and can't be compatible with the same manager. ISO/IEEE 11073 standard is a popular standard in collecting measurement data. In this paper, we propose a design of an 11073 standard adapter, which can be used as a bridge between the medical devices and the 11073 manager applications. The adapter can collect measurement data from different kinds of and types of medical devices, standard devices and non-standard devices are both fine and convert it into 11073 standard data. Using this adapter will hide the diversity of the means of communication at bottom and simplify the process of collecting standard measurement data.