Henry Broomfield
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Henry Broomfield has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Ameera X. Patel
TidalSense Limited, Cambridge, UK
3 shared publications Daniel Neville
Portsmouth Hospitals University NHS Foundation Trust
3 shared publications- Gail Hayward
Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
3 shared publications Anoop Chauhan
Respiratory Department, Portsmouth Hospitals University NHS Foundation Trust, Portsmouth, UK
2 shared publications- Gabriel Lambert
TidalSense Limited
2 shared publications - Helen Frances Ashdown
Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
2 shared publications
Latest Publications
- Open Access
Development and evaluation of a multivariate prediction model for diagnosing asthma in patients with clinically suspected asthma using capnography
Background: Diagnosis of asthma in primary care is challenged by a multistep pathway with variable adherence leading to significant misdiagnosis, late diagnosis and poor patient outcomes. This is driven by a lack of rapid, accurate, easy-to-use diagnostic tests that can reliably diagnose asthma with both high sensitivity and specificity. The objective of this work was to develop and evaluate a multivariate machine learning classifier for asthma diagnosis. The classifier was built using interpretable data processing and machine learning techniques applied to 75-second tidal breathing CO 2 recordings captured on TidalSense’s N-Tidal ® hand-held capnometer. The target population comprises patients with clinically suspected asthma who have no contraindications to performing capnometry. Methods: Capnograms were collected from 138 asthmatic and 132 non-asthmatic participants (including healthy volunteers, and those with chronic obstructive pulmonary disease (COPD), heart failure, and other cardiores-piratory conditions) recruited from both primary and secondary care. Each high-resolution CO 2 recording was transformed into 82 features (using the N-Tidal ® Diagnose 1 v1.0 software) that characterise the constituent breathing cycles. A logistic regression model was trained on these features and performance metrics generated from an unseen test set of 64 participants. Model performance was evaluated using discrimination, measured by the area under the receiver operating characteristic curve (AUROC), as well as clinically relevant predictive accuracy metrics, including positive predictive value (PPV) and negative predictive value (NPV). This was repeated 20 times with different training and testing participants for additional statistical robustness; the average and variability of these metrics were recorded. Results: The classification model achieved an AUROC of 0.91 ± 0.03%, sensitivity of 83 ± 4%, specificity of 85 ± 6%, positive predictive value (PPV) of 87 ± 4%, and negative predictive value (NPV) of 81 ± 4% in detecting asthma from a single breath recording. The model demonstrated diagnostic stability, with 95.8% of each participant’s recordings over the course of data collection being classified correctly on average. No model bias was observed with regards to sex, but performance did improve with age, possibly reflecting increasing severity of disease with age. Conclusion: This study introduces a highly accurate and interpretable multivariate diagnostic model capable of classifying asthma from a single breath recorded using the N-Tidal ® Handset. It achieves high sensitivity and specificity compared with current methods, such as spirometry, and could enable point-of-care diagnosis in patients suspected of having asthma.
Open AccessDevelopment and evaluation of a multivariate prediction model for diagnosing asthma in patients with clinically suspected asthma using capnography
Background: Diagnosis of asthma in primary care is challenged by a multistep pathway with variable adherence leading to significant misdiagnosis, late diagnosis and poor patient outcomes. This is driven by a lack of rapid, accurate, easy-to-use diagnostic tests that can reliably diagnose asthma with both high sensitivity and specificity. The objective of this work was to develop and evaluate a multivariate machine learning classifier for asthma diagnosis. The classifier was built using interpretable data processing and machine learning techniques applied to 75-second tidal breathing CO 2 recordings captured on TidalSense’s N-Tidal ® hand-held capnometer. The target population comprises patients with clinically suspected asthma who have no contraindications to performing capnometry. Methods: Capnograms were collected from 138 asthmatic and 132 non-asthmatic participants (including healthy volunteers, and those with chronic obstructive pulmonary disease (COPD), heart failure, and other cardiores-piratory conditions) recruited from both primary and secondary care. Each high-resolution CO 2 recording was transformed into 82 features (using the N-Tidal ® Diagnose 1 v1.0 software) that characterise the constituent breathing cycles. A logistic regression model was trained on these features and performance metrics generated from an unseen test set of 64 participants. Model performance was evaluated using discrimination, measured by the area under the receiver operating characteristic curve (AUROC), as well as clinically relevant predictive accuracy metrics, including positive predictive value (PPV) and negative predictive value (NPV). This was repeated 20 times with different training and testing participants for additional statistical robustness; the average and variability of these metrics were recorded. Results: The classification model achieved an AUROC of 0.91 ± 0.03%, sensitivity of 83 ± 4%, specificity of 85 ± 6%, positive predictive value (PPV) of 87 ± 4%, and negative predictive value (NPV) of 81 ± 4% in detecting asthma from a single breath recording. The model demonstrated diagnostic stability, with 95.8% of each participant’s recordings over the course of data collection being classified correctly on average. No model bias was observed with regards to sex, but performance did improve with age, possibly reflecting increasing severity of disease with age. Conclusion: This study introduces a highly accurate and interpretable multivariate diagnostic model capable of classifying asthma from a single breath recorded using the N-Tidal ® Handset. It achieves high sensitivity and specificity compared with current methods, such as spirometry, and could enable point-of-care diagnosis in patients suspected of having asthma.
- Open Access
- 24 April 2024
- Published by Taylor & Francis in COPD: Journal of Chronic Obstructive Pulmonary Disease
- Vol. 21 (1) , 2321379
Diagnosis and Severity Assessment of COPD Using a Novel Fast-Response Capnometer and Interpretable Machine Learning
According to the World Health Organisation in 2020, Chronic Obstructive Pulmonary Disease (COPD) was the third leading cause of mortality, accounting for 6% of global deaths [1]. It is estimated th...
- 24 April 2024
- Published by Taylor & Francis in COPD: Journal of Chronic Obstructive Pulmonary Disease
- Vol. 21 (1) , 2321379
Open AccessDiagnosis and Severity Assessment of COPD Using a Novel Fast-Response Capnometer and Interpretable Machine Learning
According to the World Health Organisation in 2020, Chronic Obstructive Pulmonary Disease (COPD) was the third leading cause of mortality, accounting for 6% of global deaths [1]. It is estimated th...
- Open Access
Machine Diagnosis of Chronic Obstructive Pulmonary Disease using a Novel Fast-Response Capnometer
Background: Although currently most widely used in mechanical ventilation and cardiopulmonary resuscitation, features of the carbon dioxide waveform produced through capnometry have been shown to correlate with V/Q mismatch, dead space volume, type of breathing pattern, and small airway obstruction. This study applied feature engineering and machine learning techniques to capnography data collected by the N-Tidal™ device across four clinical studies to build a classifier that could distinguish CO 2 recordings (capnograms) of patients with COPD from those without COPD. Methods: Capnography data from four longitudinal observational studies (CBRS, GBRS, CBRS2 and ABRS) was analysed from 295 patients, generating a total of 88,186 capnograms. CO 2 sensor data was processed using Cambridge Respiratory Innovations’ regulated cloud platform, performing real-time geometric analysis on CO 2 waveforms to generate 82 physiologic features per capnogram. These features were used to train machine learning classifiers to discriminate COPD from ‘non-COPD’ (a group that included healthy participants and those with other cardiorespiratory conditions); model performance was validated on independent test sets. Results: The best machine learning model (XGBoost) performance provided a class-balanced AUROC of 0·968 ± 0·017 and a positive predictive value (PPV) of 0·911 ± 0·028 for a diagnosis of COPD. The waveform features that are most important for driving classification are related to the alpha angle and expiratory plateau regions. These features correlated with spirometry readings, supporting their proposed properties as markers of COPD. Conclusion: The N-Tidal device can be used to accurately diagnose COPD in near-real-time, lending support to future use in a clinical setting. Funding: NIHR (i4i grant), Innovate UK, SBRI Healthcare and Pfizer OpenAir.
Open AccessMachine Diagnosis of Chronic Obstructive Pulmonary Disease using a Novel Fast-Response Capnometer
Background: Although currently most widely used in mechanical ventilation and cardiopulmonary resuscitation, features of the carbon dioxide waveform produced through capnometry have been shown to correlate with V/Q mismatch, dead space volume, type of breathing pattern, and small airway obstruction. This study applied feature engineering and machine learning techniques to capnography data collected by the N-Tidal™ device across four clinical studies to build a classifier that could distinguish CO 2 recordings (capnograms) of patients with COPD from those without COPD. Methods: Capnography data from four longitudinal observational studies (CBRS, GBRS, CBRS2 and ABRS) was analysed from 295 patients, generating a total of 88,186 capnograms. CO 2 sensor data was processed using Cambridge Respiratory Innovations’ regulated cloud platform, performing real-time geometric analysis on CO 2 waveforms to generate 82 physiologic features per capnogram. These features were used to train machine learning classifiers to discriminate COPD from ‘non-COPD’ (a group that included healthy participants and those with other cardiorespiratory conditions); model performance was validated on independent test sets. Results: The best machine learning model (XGBoost) performance provided a class-balanced AUROC of 0·968 ± 0·017 and a positive predictive value (PPV) of 0·911 ± 0·028 for a diagnosis of COPD. The waveform features that are most important for driving classification are related to the alpha angle and expiratory plateau regions. These features correlated with spirometry readings, supporting their proposed properties as markers of COPD. Conclusion: The N-Tidal device can be used to accurately diagnose COPD in near-real-time, lending support to future use in a clinical setting. Funding: NIHR (i4i grant), Innovate UK, SBRI Healthcare and Pfizer OpenAir.