Ameera X. Patel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ameera X. Patel has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
Daniel Neville
Portsmouth Hospitals University NHS Foundation Trust
5 shared publicationsAnoop Chauhan
Respiratory Department, Portsmouth Hospitals University NHS Foundation Trust, Portsmouth, UK
4 shared publicationsThomas Brown
Portsmouth Hospitals University NHS Foundation Trust
4 shared publicationsGabriel Lambert
TidalSense Limited, Cambridge, UK
3 shared publications- Gail Hayward
Nuffield Department of Primary Care Health Sciences, University of Oxford, Oxford, UK
3 shared publications - Henry Broomfield
TidalSense Limited
3 shared publications
Latest Publications
- Open Access
Development and evaluation of a multivariate prediction model for diagnosing asthma in patients with clinically suspected asthma using capnography
Background: Diagnosis of asthma in primary care is challenged by a multistep pathway with variable adherence leading to significant misdiagnosis, late diagnosis and poor patient outcomes. This is driven by a lack of rapid, accurate, easy-to-use diagnostic tests that can reliably diagnose asthma with both high sensitivity and specificity. The objective of this work was to develop and evaluate a multivariate machine learning classifier for asthma diagnosis. The classifier was built using interpretable data processing and machine learning techniques applied to 75-second tidal breathing CO 2 recordings captured on TidalSense’s N-Tidal ® hand-held capnometer. The target population comprises patients with clinically suspected asthma who have no contraindications to performing capnometry. Methods: Capnograms were collected from 138 asthmatic and 132 non-asthmatic participants (including healthy volunteers, and those with chronic obstructive pulmonary disease (COPD), heart failure, and other cardiores-piratory conditions) recruited from both primary and secondary care. Each high-resolution CO 2 recording was transformed into 82 features (using the N-Tidal ® Diagnose 1 v1.0 software) that characterise the constituent breathing cycles. A logistic regression model was trained on these features and performance metrics generated from an unseen test set of 64 participants. Model performance was evaluated using discrimination, measured by the area under the receiver operating characteristic curve (AUROC), as well as clinically relevant predictive accuracy metrics, including positive predictive value (PPV) and negative predictive value (NPV). This was repeated 20 times with different training and testing participants for additional statistical robustness; the average and variability of these metrics were recorded. Results: The classification model achieved an AUROC of 0.91 ± 0.03%, sensitivity of 83 ± 4%, specificity of 85 ± 6%, positive predictive value (PPV) of 87 ± 4%, and negative predictive value (NPV) of 81 ± 4% in detecting asthma from a single breath recording. The model demonstrated diagnostic stability, with 95.8% of each participant’s recordings over the course of data collection being classified correctly on average. No model bias was observed with regards to sex, but performance did improve with age, possibly reflecting increasing severity of disease with age. Conclusion: This study introduces a highly accurate and interpretable multivariate diagnostic model capable of classifying asthma from a single breath recorded using the N-Tidal ® Handset. It achieves high sensitivity and specificity compared with current methods, such as spirometry, and could enable point-of-care diagnosis in patients suspected of having asthma.
Open AccessDevelopment and evaluation of a multivariate prediction model for diagnosing asthma in patients with clinically suspected asthma using capnography
Background: Diagnosis of asthma in primary care is challenged by a multistep pathway with variable adherence leading to significant misdiagnosis, late diagnosis and poor patient outcomes. This is driven by a lack of rapid, accurate, easy-to-use diagnostic tests that can reliably diagnose asthma with both high sensitivity and specificity. The objective of this work was to develop and evaluate a multivariate machine learning classifier for asthma diagnosis. The classifier was built using interpretable data processing and machine learning techniques applied to 75-second tidal breathing CO 2 recordings captured on TidalSense’s N-Tidal ® hand-held capnometer. The target population comprises patients with clinically suspected asthma who have no contraindications to performing capnometry. Methods: Capnograms were collected from 138 asthmatic and 132 non-asthmatic participants (including healthy volunteers, and those with chronic obstructive pulmonary disease (COPD), heart failure, and other cardiores-piratory conditions) recruited from both primary and secondary care. Each high-resolution CO 2 recording was transformed into 82 features (using the N-Tidal ® Diagnose 1 v1.0 software) that characterise the constituent breathing cycles. A logistic regression model was trained on these features and performance metrics generated from an unseen test set of 64 participants. Model performance was evaluated using discrimination, measured by the area under the receiver operating characteristic curve (AUROC), as well as clinically relevant predictive accuracy metrics, including positive predictive value (PPV) and negative predictive value (NPV). This was repeated 20 times with different training and testing participants for additional statistical robustness; the average and variability of these metrics were recorded. Results: The classification model achieved an AUROC of 0.91 ± 0.03%, sensitivity of 83 ± 4%, specificity of 85 ± 6%, positive predictive value (PPV) of 87 ± 4%, and negative predictive value (NPV) of 81 ± 4% in detecting asthma from a single breath recording. The model demonstrated diagnostic stability, with 95.8% of each participant’s recordings over the course of data collection being classified correctly on average. No model bias was observed with regards to sex, but performance did improve with age, possibly reflecting increasing severity of disease with age. Conclusion: This study introduces a highly accurate and interpretable multivariate diagnostic model capable of classifying asthma from a single breath recorded using the N-Tidal ® Handset. It achieves high sensitivity and specificity compared with current methods, such as spirometry, and could enable point-of-care diagnosis in patients suspected of having asthma.
- Open Access
- 24 April 2024
- Published by Taylor & Francis in COPD: Journal of Chronic Obstructive Pulmonary Disease
- Vol. 21 (1) , 2321379
Diagnosis and Severity Assessment of COPD Using a Novel Fast-Response Capnometer and Interpretable Machine Learning
According to the World Health Organisation in 2020, Chronic Obstructive Pulmonary Disease (COPD) was the third leading cause of mortality, accounting for 6% of global deaths [1]. It is estimated th...
- 24 April 2024
- Published by Taylor & Francis in COPD: Journal of Chronic Obstructive Pulmonary Disease
- Vol. 21 (1) , 2321379
Open AccessDiagnosis and Severity Assessment of COPD Using a Novel Fast-Response Capnometer and Interpretable Machine Learning
According to the World Health Organisation in 2020, Chronic Obstructive Pulmonary Disease (COPD) was the third leading cause of mortality, accounting for 6% of global deaths [1]. It is estimated th...
- Open Access
Diagnosis and Severity Assessment of COPD using a Novel Fast-Response Capnometer And Interpretable Machine Learning
Introduction: Spirometry is the gold standard for COPD diagnosis and severity determination, but is technique-dependent, non-specific, and requires administration by a trained healthcare professional. There is a need for a fast, reliable, and precise alternative diagnostic test. This study’s aim was to use interpretable machine learning to diagnose COPD and assess severity using 75-second carbon dioxide (CO 2 ) breath records captured with TidalSense’s N-Tidal ™ capnometer. Methods: For COPD diagnosis, machine learning algorithms were trained and evaluated on 294 COPD (including GOLD stages 1-4) and 705 non-COPD participants. A logistic regression model was also trained to distinguish GOLD 1 from GOLD 4 COPD with the output probability used as an index of severity. Results: The best diagnostic model achieved an AUROC of 0.890, sensitivity of 0.771, specificity of 0.850 and positive predictive value of 0.834. A potential clinical use for this model is to rule in or rule out a diagnosis in patients where the model is most confident. Performance on test capnograms with probability > 80% and < 20% was also evaluated, yielding a PPV of 0.930 and NPV of 0.890. The severity determination model yielded an AUROC of 0.980, Sensitivity of 0.958, Specificity of 0.961 and PPV of 0.958 in distinguishing GOLD 1 from GOLD 4. Output probabilities from the severity determination model produced a correlation of 0.71 with percentage predicted FEV 1 . Conclusion: The N-Tidal ™ device could be used alongside interpretable machine learning as an accurate, point-of-care diagnostic test for COPD, particularly in primary care, as a rapid rule-in or rule-out test. N-Tidal ™ also could be effective in monitoring disease progression, providing a possible alternative to spirometry for disease monitoring. Trial registration: Please see NCT03615365 , NCT02814253 , NCT04504838 , NCT03356288 and NCT04939558 .
Open AccessDiagnosis and Severity Assessment of COPD using a Novel Fast-Response Capnometer And Interpretable Machine Learning
Introduction: Spirometry is the gold standard for COPD diagnosis and severity determination, but is technique-dependent, non-specific, and requires administration by a trained healthcare professional. There is a need for a fast, reliable, and precise alternative diagnostic test. This study’s aim was to use interpretable machine learning to diagnose COPD and assess severity using 75-second carbon dioxide (CO 2 ) breath records captured with TidalSense’s N-Tidal ™ capnometer. Methods: For COPD diagnosis, machine learning algorithms were trained and evaluated on 294 COPD (including GOLD stages 1-4) and 705 non-COPD participants. A logistic regression model was also trained to distinguish GOLD 1 from GOLD 4 COPD with the output probability used as an index of severity. Results: The best diagnostic model achieved an AUROC of 0.890, sensitivity of 0.771, specificity of 0.850 and positive predictive value of 0.834. A potential clinical use for this model is to rule in or rule out a diagnosis in patients where the model is most confident. Performance on test capnograms with probability > 80% and < 20% was also evaluated, yielding a PPV of 0.930 and NPV of 0.890. The severity determination model yielded an AUROC of 0.980, Sensitivity of 0.958, Specificity of 0.961 and PPV of 0.958 in distinguishing GOLD 1 from GOLD 4. Output probabilities from the severity determination model produced a correlation of 0.71 with percentage predicted FEV 1 . Conclusion: The N-Tidal ™ device could be used alongside interpretable machine learning as an accurate, point-of-care diagnostic test for COPD, particularly in primary care, as a rapid rule-in or rule-out test. N-Tidal ™ also could be effective in monitoring disease progression, providing a possible alternative to spirometry for disease monitoring. Trial registration: Please see NCT03615365 , NCT02814253 , NCT04504838 , NCT03356288 and NCT04939558 .
- Open Access
- 2 June 2023
- Published by Springer Nature in Respiratory Research
- Vol. 24 (1) , 1-11
Machine diagnosis of chronic obstructive pulmonary disease using a novel fast-response capnometer
Background: Although currently most widely used in mechanical ventilation and cardiopulmonary resuscitation, features of the carbon dioxide (CO2) waveform produced through capnometry have been shown to correlate with V/Q mismatch, dead space volume, type of breathing pattern, and small airway obstruction. This study applied feature engineering and machine learning techniques to capnography data collected by the N-Tidal™ device across four clinical studies to build a classifier that could distinguish CO2 recordings (capnograms) of patients with COPD from those without COPD. Methods: Capnography data from four longitudinal observational studies (CBRS, GBRS, CBRS2 and ABRS) was analysed from 295 patients, generating a total of 88,186 capnograms. CO2 sensor data was processed using TidalSense’s regulated cloud platform, performing real-time geometric analysis on CO2 waveforms to generate 82 physiologic features per capnogram. These features were used to train machine learning classifiers to discriminate COPD from ‘non-COPD’ (a group that included healthy participants and those with other cardiorespiratory conditions); model performance was validated on independent test sets. Results: The best machine learning model (XGBoost) performance provided a class-balanced AUROC of 0.985 ± 0.013, positive predictive value (PPV) of 0.914 ± 0.039 and sensitivity of 0.915 ± 0.066 for a diagnosis of COPD. The waveform features that are most important for driving classification are related to the alpha angle and expiratory plateau regions. These features correlated with spirometry readings, supporting their proposed properties as markers of COPD. Conclusion: The N-Tidal™ device can be used to accurately diagnose COPD in near-real-time, lending support to future use in a clinical setting. Trial registration: Please see NCT03615365, NCT02814253, NCT04504838 and NCT03356288.
- 2 June 2023
- Published by Springer Nature in Respiratory Research
- Vol. 24 (1) , 1-11
Open AccessMachine diagnosis of chronic obstructive pulmonary disease using a novel fast-response capnometer
Background: Although currently most widely used in mechanical ventilation and cardiopulmonary resuscitation, features of the carbon dioxide (CO2) waveform produced through capnometry have been shown to correlate with V/Q mismatch, dead space volume, type of breathing pattern, and small airway obstruction. This study applied feature engineering and machine learning techniques to capnography data collected by the N-Tidal™ device across four clinical studies to build a classifier that could distinguish CO2 recordings (capnograms) of patients with COPD from those without COPD. Methods: Capnography data from four longitudinal observational studies (CBRS, GBRS, CBRS2 and ABRS) was analysed from 295 patients, generating a total of 88,186 capnograms. CO2 sensor data was processed using TidalSense’s regulated cloud platform, performing real-time geometric analysis on CO2 waveforms to generate 82 physiologic features per capnogram. These features were used to train machine learning classifiers to discriminate COPD from ‘non-COPD’ (a group that included healthy participants and those with other cardiorespiratory conditions); model performance was validated on independent test sets. Results: The best machine learning model (XGBoost) performance provided a class-balanced AUROC of 0.985 ± 0.013, positive predictive value (PPV) of 0.914 ± 0.039 and sensitivity of 0.915 ± 0.066 for a diagnosis of COPD. The waveform features that are most important for driving classification are related to the alpha angle and expiratory plateau regions. These features correlated with spirometry readings, supporting their proposed properties as markers of COPD. Conclusion: The N-Tidal™ device can be used to accurately diagnose COPD in near-real-time, lending support to future use in a clinical setting. Trial registration: Please see NCT03615365, NCT02814253, NCT04504838 and NCT03356288.
- Open Access
Machine Diagnosis of Chronic Obstructive Pulmonary Disease using a Novel Fast-Response Capnometer
Background: Although currently most widely used in mechanical ventilation and cardiopulmonary resuscitation, features of the carbon dioxide waveform produced through capnometry have been shown to correlate with V/Q mismatch, dead space volume, type of breathing pattern, and small airway obstruction. This study applied feature engineering and machine learning techniques to capnography data collected by the N-Tidal™ device across four clinical studies to build a classifier that could distinguish CO 2 recordings (capnograms) of patients with COPD from those without COPD. Methods: Capnography data from four longitudinal observational studies (CBRS, GBRS, CBRS2 and ABRS) was analysed from 295 patients, generating a total of 88,186 capnograms. CO 2 sensor data was processed using Cambridge Respiratory Innovations’ regulated cloud platform, performing real-time geometric analysis on CO 2 waveforms to generate 82 physiologic features per capnogram. These features were used to train machine learning classifiers to discriminate COPD from ‘non-COPD’ (a group that included healthy participants and those with other cardiorespiratory conditions); model performance was validated on independent test sets. Results: The best machine learning model (XGBoost) performance provided a class-balanced AUROC of 0·968 ± 0·017 and a positive predictive value (PPV) of 0·911 ± 0·028 for a diagnosis of COPD. The waveform features that are most important for driving classification are related to the alpha angle and expiratory plateau regions. These features correlated with spirometry readings, supporting their proposed properties as markers of COPD. Conclusion: The N-Tidal device can be used to accurately diagnose COPD in near-real-time, lending support to future use in a clinical setting. Funding: NIHR (i4i grant), Innovate UK, SBRI Healthcare and Pfizer OpenAir.
Open AccessMachine Diagnosis of Chronic Obstructive Pulmonary Disease using a Novel Fast-Response Capnometer
Background: Although currently most widely used in mechanical ventilation and cardiopulmonary resuscitation, features of the carbon dioxide waveform produced through capnometry have been shown to correlate with V/Q mismatch, dead space volume, type of breathing pattern, and small airway obstruction. This study applied feature engineering and machine learning techniques to capnography data collected by the N-Tidal™ device across four clinical studies to build a classifier that could distinguish CO 2 recordings (capnograms) of patients with COPD from those without COPD. Methods: Capnography data from four longitudinal observational studies (CBRS, GBRS, CBRS2 and ABRS) was analysed from 295 patients, generating a total of 88,186 capnograms. CO 2 sensor data was processed using Cambridge Respiratory Innovations’ regulated cloud platform, performing real-time geometric analysis on CO 2 waveforms to generate 82 physiologic features per capnogram. These features were used to train machine learning classifiers to discriminate COPD from ‘non-COPD’ (a group that included healthy participants and those with other cardiorespiratory conditions); model performance was validated on independent test sets. Results: The best machine learning model (XGBoost) performance provided a class-balanced AUROC of 0·968 ± 0·017 and a positive predictive value (PPV) of 0·911 ± 0·028 for a diagnosis of COPD. The waveform features that are most important for driving classification are related to the alpha angle and expiratory plateau regions. These features correlated with spirometry readings, supporting their proposed properties as markers of COPD. Conclusion: The N-Tidal device can be used to accurately diagnose COPD in near-real-time, lending support to future use in a clinical setting. Funding: NIHR (i4i grant), Innovate UK, SBRI Healthcare and Pfizer OpenAir.
- Open Access
- 1 January 2015
- Published by Elsevier in NeuroImage: Clinical
- Vol. 9, 607-616
Semi-metric analysis of the functional brain network: Relationship with familial risk for psychotic disorder
- 1 January 2015
- Published by Elsevier in NeuroImage: Clinical
- Vol. 9, 607-616
Open AccessSemi-metric analysis of the functional brain network: Relationship with familial risk for psychotic disorder