MLMaribí Isomar Terán Lozada

Maribí Isomar Terán Lozada

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Maribí Isomar Terán Lozada has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Load‐To‐Failure of Cantilevered Provisional Implant‐Supported Prostheses: Conventional Versus 3D ‐Printed Resins

    by Térsia Cristina Silva Macedo, Carolina Neves Tannous Dib, Maribi Isomar Terán Lozada, João Pedro Alves Silva, Karla Zancopé

    Objective: Cantilever extensions in full‐arch implant‐supported provisional prostheses represent a clinical challenge frequently associated with biomechanical complications. This study aimed to evaluate the load‐to‐failure and deflection of acrylic and 3D‐printed resins used in the cantilever region of implant‐supported provisional prostheses fabricated over mini‐abutment cylinders. Materials and Methods: Forty standardized specimens with 15‐mm cantilever were allocated into four groups ( n = 10): auto‐polymerized resin (RA), high‐impact thermo‐polymerized resin (RD), 3D‐printed resin (RI) and thermo‐polymerized denture resin reinforced with metallic infrastructure (RT, control). Load‐to‐failure and displacement were measured using a universal testing machine and deflectometer (Instron). Data were analyzed using one‐way ANOVA and Tukey's post hoc test ( α = 0.05). Results: Significant differences were observed among all materials ( p < 0.001). The control group showed the highest load‐to‐failure (553 N), followed by RI (506 N), RD (440 N), and RA (396 N). The 3D‐printed resin group exhibited the lowest deflection value (2.33 mm) and the high‐impact resin the greatest (5.07 mm). Conclusion: Material selection critically influences the biomechanical stability of cantilevered provisional implant prostheses. The high‐impact resin showed higher degree of flexibility; and the RI group greater load bearing capacity, time efficiency, and predictability, therefore both are suitable alternatives for full‐arch temporary implant‐supported rehabilitations.

  • Open Access

    Biomechanical Analysis of 3D Printed and Thermoformed EVA Custom‐Made Mouthguard: Experimental and Finite Element Analyses

    by Airin Karelys Avendaño Rondon, Izabela Batista Cordeiro, Maribí Isomar Terán Lozada, Gustavo Mendonça, Priscilla Barbosa Ferreira Soares, Paulo Sergio Borella, Carlos José Soares

    Background/Objective: 3D printed materials have been evaluated for fabricating mouthguards; however, little is known about their biomechanical performance in preventing dental trauma. This study aimed to compare two 3D printed polymers and three ethylene vinyl acetate (EVA) sheets used for mouthguard fabrication regarding their mechanical properties and stress–strain behavior during impact, analyzed through finite element analysis (FEA). Materials and Methods: Two 3D printed polymers, KeyGuard (Keystone) and DimaPrint (Kulzer), and three EVA sheets, Bio‐art, Essence Dental, and Proform, were used to create the specimens following ISO 37‐II ( n = 10). Shore A hardness was measured on the surface. The breaking force ( F , N), elongation (EL, %), ultimate tensile strength (UTS, MPa), and elastic modulus (E, MPa) were measured using a universal testing machine (EMIC). Density ( ρ , g/cm 3 ) was determined using the test method following ASTM D792. Poisson's ratio was calculated by using axial tensile tests following ASTM D638. Scanning electron microscopy was used to examine the surfaces of EVAs and 3D printed polymers. A two‐dimensional finite element model of the maxillary structure and upper incisor was evaluated with and without a 4.0 mm mouthguard made from each material. An impact simulation was performed by striking the upper incisor with a rigid surface at 1 m/s (3.6 km/h). Strain and modified von Mises stress distributions were evaluated, and mouthguard displacement relative to the tooth was calculated. Results: One‐way ANOVA revealed significant differences among the tested mouthguards for all evaluated parameters ( p < 0.01). Essence Dental showed the highest and DimaPrint the lowest values of F and UTS values ( p < 0.01). Proform was the highest, and DimaPrint had the lowest EL values ( p < 0.01). DimaPrint and KeyGuard had the highest, and Proform had the lowest E values ( p < 0.01). KeyGuard, Essence Dental, and Bio‐art had higher Shore A values than Proform and DimaPrint ( p < 0.01). The 3D printed polymer group had significantly higher Poisson's ratio values than EVAs. The density values were similar for all tested materials ( p = 0.055). The absence of a mouthguard led to greater stress and strain on the impacted tooth. All mouthguards significantly reduced these values, showing comparable shock‐absorbing capacity. Displacement was generally lower in the buccal region and increased toward the palatal side. Conclusion: Although the 3D‐printed polymers exhibited mechanical properties different from EVA materials, all mouthguards demonstrated similar effectiveness for reducing stress and strain on the impacted tooth, indicating comparable protection against dental trauma.


  • Digital Workflow for the Fabrication of a Carbon Fiber Face Guard to Prevent Orofacial Trauma: An overview and Case Report

    by Airin Karelys Avendaño Rondon, Maribí Isomar Terán Lozada, Izabela Batista Cordeiro, Maryuri del Carmen Macias Bautista, Thiago Leite Beaini, Priscilla Barbosa Ferreira Soares, Carlos José Soares

    Face guards effectively reduce the risk of facial injuries in athletes. This study aimed to present a case report and discuss the scientific literature on facial trauma in sports and innovations in the fabrication of face guards. Global regulatory disparities and the importance of education in promoting the use of protective equipment are key factors for injury prevention. Conventionally, alginate impressions have been widely used in manufacturing processes. However, the implementation of digital workflows involving photogrammetry and three‐dimensional printing offers a promising alternative for fabricating customized face guards. Various materials have been used for fabricating the outer layer of face guards, with carbon fibers standing out for their ability to enhance both protection and comfort. These findings suggest that digital innovations and custom designs can improve athlete safety and increase comfort and confidence, thereby contributing to a safer sports environment.


  • Adaptation and Biomechanical Performance of Custom‐Fit Mouthguards Produced Using Conventional and Digital Workflows: A Comparative In Vitro Strain Analysis

    by Airin Karelys Avendaño Rondon, Maribí Isomar Terán Lozada, Izabela Batista Cordeiro, Paulo Cesar Junqueira Bandeira, Liran Levin, Priscilla Barbosa Ferreira Soares, Carlos José Soares

    Background/Objectives: The use of different models for the fabrication of custom‐fit mouthguards (MTGs) can affect their final thickness, adaptation, and shock‐absorption properties. This study aimed to evaluate the adaptation, thickness, and shock absorption of ethylene‐vinyl acetate (EVA) thermoplastic MTGs produced using conventional plaster or three‐dimensional (3D) printed models.Materials and Methods: A typical model with simulated soft gum tissue was used as the reference model to produce MTGs with the following two different protocols: plast‐MTG using a conventional impression and plaster model (n = 10) and 3DPr‐MTG using a digital scanning and 3D printed model (n = 10). A custom‐fit MTG was fabricated using EVA sheets (Bioart) plasticized over different models. The MTG thickness (mm), internal adaptation (mm) to the typodontic model, and voids in the area (mm2) between the two EVA layers were measured using cone‐beam computed tomography images and Mimics software (Materialize). The shock absorption of the MTG was measured using a strain‐gauge test with a pendulum impact at 30° with a steel ball over the typodont model with and without MTGs. Data were analyzed using one‐way analysis of variance with repeated measurements, followed by Tukey's post hoc tests.Results: The 3DPr‐MTG showed better adaptation than that of the Plast‐MTG at the incisal/occlusal and lingual tooth surfaces (p < 0.001). The 3DPr‐MTG showed a thickness similar to that of the Plast‐MTG, irrespective of the measured location. MTGs produced using both model types significantly reduced the strain values during horizontal impact (3DPr‐MTG 86.2% and Plast‐MTG 87.0%) compared with the control group without MTG (p < 0.001).Conclusion: The MTGs showed the required standards regarding thickness, adaptation, and biomechanical performance, suggesting that the number and volume of voids had no significant impact on their functionality. Three‐dimensional printed models are a viable alternative for MTG production, providing better adaptation than the Plast‐MTG at the incisal/occlusal and lingual tooth surfaces and similar performance as the MTG produced with the conventional protocol.


  • Effect of different materials for conventional and 3D‐printed models on the mechanical properties of ethylene‐vinyl acetate utilized for fabricating custom‐fit mouthguards

    by Airin Karelys Avendaño Rondón, Maribí Isomar Terán Lozada, Priscilla Barbosa Ferreira Soares, Luis Henrique Araujo Raposo, Carlos José Soares

    Background/Aim: The interaction between the ethylene‐vinyl acetate (EVA) with distinct materials utilized for obtaining dental models can affect the performance of resulting mouthguards. This study attempted to evaluate the effect of different materials for conventional (dental stone) or 3D‐printed (resin) models on EVA's physical and mechanical properties and surface characteristics.Material and Methods: EVA sheets (Bioart) were laminated over four model types: GIV, conventional Type IV dental stone model (Zhermak); ReG, resin‐reinforced Type IV dental stone model (Zero Stone); 3DnT, 3D resin printed model (Anycubic) without surface treatment; 3DT, 3D‐printed model (Anycubic) with water‐soluble gel (KY Jelly Lubricant, Johnson & Johnson) coating during post‐curing process. The EVA specimens were cut following the ISO 37‐II standard (n = 30). Shore A hardness was measured before and after plasticization on the contact (internal) or opposite (external) surfaces with the model. The breaking force (F, N), elongation (EL, mm), and ultimate tensile strength (UTS, MPa) were measured using a universal testing machine. Macro‐photography and scanning electron microscopy were adopted for classifying the EVA surface alteration. Data were analyzed by one‐way ANOVA with repeated measures, followed by Tukey's test (α = .05).Results: Plasticization significantly decreased Shore A values for the tested EVA regardless of the model type (p < .001). Higher F, El, and UTS values were verified for the EVA with 3DT and GIV models compared to ReG and 3DnT (p < .001). 3DnT models resulted in severe surface alteration and a greater reduction of the mechanical properties of the EVA.Conclusion: The interaction of EVA with 3D resin‐printed models without surface treatment or resin‐reinforced Type IV dental stone models significantly affected the physical and mechanical properties of this material. The utilization of water‐soluble gel coating during the post‐curing process of 3D resin printed models improved the mechanical properties of the EVA, similarly when this material was plasticized over conventional Type IV dental stone model.


  • Effect of surface treatment of ethylene vinyl acetate on the delamination of custom‐fitted mouthguards

    by Calebe de Melo, Júlia Borges Resende, Maribí Isomar Terán Lozada, Lilibeth Carola Leyton Mendoza, Maria Tereza Hordones Ribeiro, Priscila Barbosa Ferreira Soares, Carlos José Soares

    Background/Aim: Contamination of ethylene vinyl acetate (EVA) during mouthguard fabrication can cause delamination. The study evaluated the effects of different EVA surface treatments on the contact angle, laminate bond strength, and elongation capacity.Materials and Methods: Specimens of two bonded EVA plates were prepared (n = 30). The Shore A hardness of standardized EVA plate specimens was measured before and after thermo‐plasticization. The EVA plates were randomly allocated to one of five different surface treatment groups: no treatment (control); isopropyl alcohol, 100%; chloroform, 99.8%; self‐cure acrylic resin monomer (methacrylate, ethylene glycol dimethacrylate, and chemical initiator—amine type); and ethyl alcohol, 70%. The maximum breaking force and elongation at the site of fracture were recorded using a universal testing machine. The contact angle surface was measured using ImageJ software. Scanning electron microscopy of the EVA surface was performed. The laminate bond strength was obtained by dividing the maximum breaking force by the bonding area between the two EVA plates. The laminate bond strength and maximum elongation data were analyzed by one‐way ANOVA, followed by the Tukey's and the Dunnet test. The failure mode data was analyzed using the chi‐square test (α = .05).Results: EVA surface treatment significantly influenced the laminate bond strength and maximum elongation (p < .001). The control group had a higher contact angle and significantly lower laminate bond strength and maximum elongation than the other groups (p < .001). The acrylic resin monomer and chloroform‐treated specimens had similar laminate bond strength and maximum elongation. The acrylic resin monomer group had a significantly lower contact angle (p < .001).Conclusions: All treatments had a significantly higher laminate bond strength and maximum elongation than the control group. The acrylic resin monomer and chloroform groups had a significantly higher laminate bond strength and maximum elongation and the acrylic resin monomer group had a lower contact angle than the other groups. The chloroform should be avoided due its hazardous effects.