Loren Temple
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Loren Temple has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
- Hugh Coe
Centre for Atmospheric Science, Department of Earth and Environmental Sciences, School of Natural Sciences, University of Manchester, Manchester, M13 9PL, UK
13 shared publications - James Daniel Lee
Department of Chemistry, University of York, York, YO10 5DD, UK
13 shared publications - Mingxi Yang
Plymouth Marine Laboratory, Plymouth, PL1 3DH, UK
12 shared publications - Peter M. Edwards
Wolfson Atmospheric Chemistry Laboratories, Department of Chemistry, University of York, York, UK
12 shared publications - Thomas J. Bannan
Department for Earth and Environmental Sciences, University of Manchester, Manchester, M13 9PL, UK
12 shared publications Emily Matthews
Department of Earth and Environmental Sciences, University of Manchester, Manchester, UK
11 shared publications
Latest Publications
- Open Access
- 17 February 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (4) , 1165-1178
An intercomparison of aircraft sulfur dioxide measurements in clean and polluted marine environments
The University of York's laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) analyser and iodide chemical ionisation mass spectrometer (I−CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes, the LIF instrument and PF analyser compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3σ) of 0.07 ppb at 10 s compared with 0.4 ppb for the PF analyser. Quantification of SO2 using I−CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air masses. A comparison of response time was also made, for which the I−CIMS and LIF instrument proved much faster than the PF analyser with 3 e-folding times of 0.6, 2 and 17 s respectively. This work demonstrates the importance of sensitive instrumentation like the LIF system for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- 17 February 2026
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 19 (4) , 1165-1178
Open AccessAn intercomparison of aircraft sulfur dioxide measurements in clean and polluted marine environments
The University of York's laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) analyser and iodide chemical ionisation mass spectrometer (I−CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes, the LIF instrument and PF analyser compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3σ) of 0.07 ppb at 10 s compared with 0.4 ppb for the PF analyser. Quantification of SO2 using I−CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air masses. A comparison of response time was also made, for which the I−CIMS and LIF instrument proved much faster than the PF analyser with 3 e-folding times of 0.6, 2 and 17 s respectively. This work demonstrates the importance of sensitive instrumentation like the LIF system for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- Open Access
- 5 December 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-23
Reply on RC1
The University of York’s laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) and iodide chemical ionisation mass spectrometer (I-CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes LIF and PF compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3 σ) of 0.07 ppb at 10 seconds compared with 0.4 ppb for the PF. Quantification of SO2 using I-CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air mases. A comparison of response time was also made, for which the I-CIMS and LIF proved much faster than the PF with 3-efolding times of 0.6, 2 and 17 seconds respectively. This work demonstrates the importance of sensitive instrumentation like the LIF for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- 5 December 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-23
Open AccessReply on RC1
The University of York’s laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) and iodide chemical ionisation mass spectrometer (I-CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes LIF and PF compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3 σ) of 0.07 ppb at 10 seconds compared with 0.4 ppb for the PF. Quantification of SO2 using I-CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air mases. A comparison of response time was also made, for which the I-CIMS and LIF proved much faster than the PF with 3-efolding times of 0.6, 2 and 17 seconds respectively. This work demonstrates the importance of sensitive instrumentation like the LIF for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- Open Access
- 5 December 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-23
Reply on RC2
The University of York’s laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) and iodide chemical ionisation mass spectrometer (I-CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes LIF and PF compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3 σ) of 0.07 ppb at 10 seconds compared with 0.4 ppb for the PF. Quantification of SO2 using I-CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air mases. A comparison of response time was also made, for which the I-CIMS and LIF proved much faster than the PF with 3-efolding times of 0.6, 2 and 17 seconds respectively. This work demonstrates the importance of sensitive instrumentation like the LIF for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- 5 December 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-23
Open AccessReply on RC2
The University of York’s laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) and iodide chemical ionisation mass spectrometer (I-CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes LIF and PF compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3 σ) of 0.07 ppb at 10 seconds compared with 0.4 ppb for the PF. Quantification of SO2 using I-CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air mases. A comparison of response time was also made, for which the I-CIMS and LIF proved much faster than the PF with 3-efolding times of 0.6, 2 and 17 seconds respectively. This work demonstrates the importance of sensitive instrumentation like the LIF for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- Open Access
- 5 December 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-23
Reply on RC1
The University of York’s laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) and iodide chemical ionisation mass spectrometer (I-CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes LIF and PF compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3 σ) of 0.07 ppb at 10 seconds compared with 0.4 ppb for the PF. Quantification of SO2 using I-CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air mases. A comparison of response time was also made, for which the I-CIMS and LIF proved much faster than the PF with 3-efolding times of 0.6, 2 and 17 seconds respectively. This work demonstrates the importance of sensitive instrumentation like the LIF for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- 5 December 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-23
Open AccessReply on RC1
The University of York’s laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) and iodide chemical ionisation mass spectrometer (I-CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes LIF and PF compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3 σ) of 0.07 ppb at 10 seconds compared with 0.4 ppb for the PF. Quantification of SO2 using I-CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air mases. A comparison of response time was also made, for which the I-CIMS and LIF proved much faster than the PF with 3-efolding times of 0.6, 2 and 17 seconds respectively. This work demonstrates the importance of sensitive instrumentation like the LIF for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- Open Access
- 24 October 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-23
Comment on egusphere-2025-3678
The University of York’s laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) and iodide chemical ionisation mass spectrometer (I-CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes LIF and PF compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3 σ) of 0.07 ppb at 10 seconds compared with 0.4 ppb for the PF. Quantification of SO2 using I-CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air mases. A comparison of response time was also made, for which the I-CIMS and LIF proved much faster than the PF with 3-efolding times of 0.6, 2 and 17 seconds respectively. This work demonstrates the importance of sensitive instrumentation like the LIF for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- 24 October 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-23
Open AccessComment on egusphere-2025-3678
The University of York’s laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) and iodide chemical ionisation mass spectrometer (I-CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes LIF and PF compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3 σ) of 0.07 ppb at 10 seconds compared with 0.4 ppb for the PF. Quantification of SO2 using I-CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air mases. A comparison of response time was also made, for which the I-CIMS and LIF proved much faster than the PF with 3-efolding times of 0.6, 2 and 17 seconds respectively. This work demonstrates the importance of sensitive instrumentation like the LIF for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- Open Access
- 3 October 2025
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Atmospheres
- Vol. 5 (12) , 1282-1296
SO 2 and NO x emissions from ships in North-East Atlantic waters: in situ measurements and comparison with an emission model
Measurements of apparent fuel sulfur content in ship exhausts (aFSC) and NOx/CO2 ratios were made from an airborne and ground-based platforms in the open Atlantic Ocean and the European sulfur emission control area (SECA) during multiple field campaigns from 2019 to 2023. In the open ocean a nearly 10-fold decrease in the mean aFSC demonstrates the strong impact the International Maritime Organization regulation change in 2020 had on sulfur emissions from ships. In 2019, 8 ships out of 19 showed a measured aFSC higher than the 3.5% limit at the time and in 2021 and 2022, 5 ships out of 78 were observed to be higher than the new 0.5% limit. In the SECA in the English Channel, the average aFSC across both 2019 and 2021 measurements was 0.04 ± 0.01%, well below the more stringent 0.1% limit. In the port of Valencia, Spain, which is not in a SECA, observed aFSC was on average much lower than in the open ocean and close to the EU Sulfur directive of 0.1% fuel sulfur content in port areas if the ship stays more than 2 hours in port. In the Port of Tyne (within the European SECA), the aFSC is virtually identical to those measured in the English Channel, with no ships breaching the 0.1% limit. On average, measured aFSCs agree well with the estimates of the Ship Traffic Emission Assessment Model (STEAM3), although the model does not pick up outliers that breach limits. In the open ocean in 2019 the NOx/CO2 ratio was 0.021 ± 0.002, with ratios observed in port significantly lower (Port of Tyne 0.009 ± 0.001, Port of Valencia 0.011 ± 0.001), with a switch to auxiliary engines in ports a potential reason for this lower emission ratio. This work presents the first aircraft-based measurements of aFSC from ships outside of sulfur control zones since the change in sulfur emission regulations in 2020 and largely justifies the assumption that is often made that ships now emit around 7 times less sulfur than before 2020.
- 3 October 2025
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Atmospheres
- Vol. 5 (12) , 1282-1296
Open AccessSO 2 and NO x emissions from ships in North-East Atlantic waters: in situ measurements and comparison with an emission model
Measurements of apparent fuel sulfur content in ship exhausts (aFSC) and NOx/CO2 ratios were made from an airborne and ground-based platforms in the open Atlantic Ocean and the European sulfur emission control area (SECA) during multiple field campaigns from 2019 to 2023. In the open ocean a nearly 10-fold decrease in the mean aFSC demonstrates the strong impact the International Maritime Organization regulation change in 2020 had on sulfur emissions from ships. In 2019, 8 ships out of 19 showed a measured aFSC higher than the 3.5% limit at the time and in 2021 and 2022, 5 ships out of 78 were observed to be higher than the new 0.5% limit. In the SECA in the English Channel, the average aFSC across both 2019 and 2021 measurements was 0.04 ± 0.01%, well below the more stringent 0.1% limit. In the port of Valencia, Spain, which is not in a SECA, observed aFSC was on average much lower than in the open ocean and close to the EU Sulfur directive of 0.1% fuel sulfur content in port areas if the ship stays more than 2 hours in port. In the Port of Tyne (within the European SECA), the aFSC is virtually identical to those measured in the English Channel, with no ships breaching the 0.1% limit. On average, measured aFSCs agree well with the estimates of the Ship Traffic Emission Assessment Model (STEAM3), although the model does not pick up outliers that breach limits. In the open ocean in 2019 the NOx/CO2 ratio was 0.021 ± 0.002, with ratios observed in port significantly lower (Port of Tyne 0.009 ± 0.001, Port of Valencia 0.011 ± 0.001), with a switch to auxiliary engines in ports a potential reason for this lower emission ratio. This work presents the first aircraft-based measurements of aFSC from ships outside of sulfur control zones since the change in sulfur emission regulations in 2020 and largely justifies the assumption that is often made that ships now emit around 7 times less sulfur than before 2020.
- Open Access
- 15 August 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-23
Comment on egusphere-2025-3678
The University of York’s laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) and iodide chemical ionisation mass spectrometer (I-CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes LIF and PF compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3 σ) of 0.07 ppb at 10 seconds compared with 0.4 ppb for the PF. Quantification of SO2 using I-CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air mases. A comparison of response time was also made, for which the I-CIMS and LIF proved much faster than the PF with 3-efolding times of 0.6, 2 and 17 seconds respectively. This work demonstrates the importance of sensitive instrumentation like the LIF for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- 15 August 2025
- Published by Copernicus GmbH
- Vol. 2025, 1-23
Open AccessComment on egusphere-2025-3678
The University of York’s laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) and iodide chemical ionisation mass spectrometer (I-CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes LIF and PF compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3 σ) of 0.07 ppb at 10 seconds compared with 0.4 ppb for the PF. Quantification of SO2 using I-CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air mases. A comparison of response time was also made, for which the I-CIMS and LIF proved much faster than the PF with 3-efolding times of 0.6, 2 and 17 seconds respectively. This work demonstrates the importance of sensitive instrumentation like the LIF for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- Open Access
- 11 August 2025
- Published by Copernicus GmbH
Supplementary material to "An intercomparison of aircraft sulfur dioxide measurements in clean and polluted marine environments"
- 11 August 2025
- Published by Copernicus GmbH
Open AccessSupplementary material to "An intercomparison of aircraft sulfur dioxide measurements in clean and polluted marine environments"
- Open Access
- 11 August 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-23
An intercomparison of aircraft sulfur dioxide measurements in clean and polluted marine environments
The University of York’s laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) and iodide chemical ionisation mass spectrometer (I-CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes LIF and PF compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3 σ) of 0.07 ppb at 10 seconds compared with 0.4 ppb for the PF. Quantification of SO2 using I-CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air mases. A comparison of response time was also made, for which the I-CIMS and LIF proved much faster than the PF with 3-efolding times of 0.6, 2 and 17 seconds respectively. This work demonstrates the importance of sensitive instrumentation like the LIF for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- 11 August 2025
- Published by Copernicus GmbH in EGUsphere
- Vol. 2025, 1-23
Open AccessAn intercomparison of aircraft sulfur dioxide measurements in clean and polluted marine environments
The University of York’s laser-induced fluorescence (LIF) instrument for measuring sulfur dioxide (SO2) was compared to a commercial pulsed fluorescence (PF) and iodide chemical ionisation mass spectrometer (I-CIMS) aboard the UK FAAM research aircraft in both remote and ship-polluted marine environments. In high SO2 concentration plumes LIF and PF compared well, but LIF was the only instrument capable of SO2 measurements in the remote marine boundary layer due to its campaign limit of detection (LoD, 3 σ) of 0.07 ppb at 10 seconds compared with 0.4 ppb for the PF. Quantification of SO2 using I-CIMS was challenging due to a significant interference, but good signal correlation with the other instruments was observed in polluted air mases. A comparison of response time was also made, for which the I-CIMS and LIF proved much faster than the PF with 3-efolding times of 0.6, 2 and 17 seconds respectively. This work demonstrates the importance of sensitive instrumentation like the LIF for quantifying low concentrations of SO2, such as over remote marine environments, at the time resolutions required for a fast moving platform. This is particularly relevant now as a result of more stringent sulfur emission regulations for shipping, and likely more so in the future as anthropogenic SO2 concentrations continue to decline.
- Open Access
- 20 January 2025
- Published by Copernicus GmbH
Laser based observations of key inorganics (LOKI) on-board the UK research aircraft
The UK research aircraft is being equipped with flux capable measurements of NO, NO2, SO2 and O3 in the Laser based Observation of Key Inorganics (LOKI) instrument rack. All instruments within the rack are being made in-house.This presentation will discuss the aspects of the new instrumentation as well as the sample inlets used that allow high time resolution (10 Hz), high precision measurements to be made over the working envelope of the aircraft.The need for this improvement in the gas sensing capabilities on board is driven by a number of factors: the increasing desire to use flux measurements to calculate emission rates and identify sources, smaller changes in concentration being of interest (SO2 depletion in clouds) as well as reductions in absolute ambient concentrations of some of these species below the detection limits of currently deployed instrumentation.Laser Induced Fluorescence is used for NO (Rollins et al., 2020), NO2 (converted to NO), SO2 (Rollins et al., 2016), with O3 being monitored using Broadband Cavity Enhanced Absorption Spectroscopy (BBCEAS) (Hannun et al., 2020).
- 20 January 2025
- Published by Copernicus GmbH
Open AccessLaser based observations of key inorganics (LOKI) on-board the UK research aircraft
The UK research aircraft is being equipped with flux capable measurements of NO, NO2, SO2 and O3 in the Laser based Observation of Key Inorganics (LOKI) instrument rack. All instruments within the rack are being made in-house.This presentation will discuss the aspects of the new instrumentation as well as the sample inlets used that allow high time resolution (10 Hz), high precision measurements to be made over the working envelope of the aircraft.The need for this improvement in the gas sensing capabilities on board is driven by a number of factors: the increasing desire to use flux measurements to calculate emission rates and identify sources, smaller changes in concentration being of interest (SO2 depletion in clouds) as well as reductions in absolute ambient concentrations of some of these species below the detection limits of currently deployed instrumentation.Laser Induced Fluorescence is used for NO (Rollins et al., 2020), NO2 (converted to NO), SO2 (Rollins et al., 2016), with O3 being monitored using Broadband Cavity Enhanced Absorption Spectroscopy (BBCEAS) (Hannun et al., 2020).