Joseph Strehlow
Research Subjects
Joseph Strehlow has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Chun-Shang Wong
Los Alamos National Laboratory
9 shared publications - Brian James Albright
Los Alamos National Laboratory
8 shared publications - Chengkun Huang
Los Alamos National Laboratory 1 , Los Alamos, New Mexico 87545
8 shared publications - Sasikumar Palaniyappan
Los Alamos National Laboratory , Los Alamos, New Mexico 87545
8 shared publications - Scott Vernon Luedtke
Los Alamos National Laboratory, Los Alamos, USA
8 shared publications - Alemayehu Bogale
Center for Energy Research, University of California San Diego 2 , La Jolla, California 92093
7 shared publications
Latest Publications
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
A Compton-based filter stack spectrometer for high-fidelity MeV x-ray spectrum unfolding
High-energy x-ray sources are widely used across many fields and industries. Understanding and characterizing these sources is critical for these potential applications and uses. The filter stack spectrometer (FSS) is a compact and portable diagnostic that employs a stack of alternating image plate detectors and filters, and when paired with the unfolding routine based on randomized perturbative minimization methods, it can characterize these sources with high accuracy. However, limitations such as large measurement uncertainties and flattened attenuation curves in the MeV photon range make the spectral inversion difficult and less accurate. In this paper, we present a novel filter stack design that enhances the sensitivity of the FSS by leveraging Compton electrons generated in high-Z filters. This approach produces a more distinct diagnostic signal, making the spectrometer better suited for higher photon energies and more resilient to experimental uncertainties. We also demonstrate the design process for the filter stack through our modular Monte Carlo N-particle approach, allowing us to calculate response matrices rapidly.
- 1 September 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (9)
A Compton-based filter stack spectrometer for high-fidelity MeV x-ray spectrum unfolding
High-energy x-ray sources are widely used across many fields and industries. Understanding and characterizing these sources is critical for these potential applications and uses. The filter stack spectrometer (FSS) is a compact and portable diagnostic that employs a stack of alternating image plate detectors and filters, and when paired with the unfolding routine based on randomized perturbative minimization methods, it can characterize these sources with high accuracy. However, limitations such as large measurement uncertainties and flattened attenuation curves in the MeV photon range make the spectral inversion difficult and less accurate. In this paper, we present a novel filter stack design that enhances the sensitivity of the FSS by leveraging Compton electrons generated in high-Z filters. This approach produces a more distinct diagnostic signal, making the spectrometer better suited for higher photon energies and more resilient to experimental uncertainties. We also demonstrate the design process for the filter stack through our modular Monte Carlo N-particle approach, allowing us to calculate response matrices rapidly.
- Open Access
- 1 June 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (6)
Energy response characterization of current-mode MeV Cherenkov aerogel detectors
Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm3, from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.
- 1 June 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (6)
Open AccessEnergy response characterization of current-mode MeV Cherenkov aerogel detectors
Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm3, from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.
- Open Access
- 1 April 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (4)
The role of focusing geometry in MeV x-ray production from petawatt laser–solid interaction
Relativistic laser–plasma interactions provide a compact and flexible route to generating bright, ultrashort pulses of MeV x rays, with applications in high-energy density science, nuclear physics, and radiography. Despite extensive study of intensity scaling in laser-driven electron acceleration, the role of focusing geometry and focal-volume effects in MeV radiation production remains insufficiently understood. Here, we present experimental and kinetic simulation results from the Texas Petawatt Laser (120 J, 140 fs) in which the focusing geometry (f/3 or f/1.5) is varied, while the laser energy and pulse duration are fixed. Experimentally, the f/3 geometry produces approximately three times more MeV radiation than the f/1.5 geometry, despite its twofold lower nominal vacuum intensity. This result is based on the time-integrated radiation per unit solid angle, as measured along the diagnostic line of sight. Three-dimensional particle-in-cell simulations reproduce this trend when a modest (10s of μm) effective focal plane shift is introduced, demonstrating that relativistic laser–plasma coupling is highly sensitive to focal geometry in the presence of a preplasma. This behavior is consistent with differences in interaction length and effective intensity at the critical surface between the two configurations. The sensitivity of the tightly focused f/1.5 configuration (zR≈ 5 μm) reflects the combined influence of thermal lensing and an extended preplasma, while the f/3 geometry (zR≈ 80 μm) remains comparatively robust. These results demonstrate a breakdown of conventional intensity scaling and identify focusing geometry as a critical control parameter for MeV electron and x-ray generation at petawatt powers. Implications for laser–plasma-based radiographic facilities are also discussed.
- 1 April 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (4)
Open AccessThe role of focusing geometry in MeV x-ray production from petawatt laser–solid interaction
Relativistic laser–plasma interactions provide a compact and flexible route to generating bright, ultrashort pulses of MeV x rays, with applications in high-energy density science, nuclear physics, and radiography. Despite extensive study of intensity scaling in laser-driven electron acceleration, the role of focusing geometry and focal-volume effects in MeV radiation production remains insufficiently understood. Here, we present experimental and kinetic simulation results from the Texas Petawatt Laser (120 J, 140 fs) in which the focusing geometry (f/3 or f/1.5) is varied, while the laser energy and pulse duration are fixed. Experimentally, the f/3 geometry produces approximately three times more MeV radiation than the f/1.5 geometry, despite its twofold lower nominal vacuum intensity. This result is based on the time-integrated radiation per unit solid angle, as measured along the diagnostic line of sight. Three-dimensional particle-in-cell simulations reproduce this trend when a modest (10s of μm) effective focal plane shift is introduced, demonstrating that relativistic laser–plasma coupling is highly sensitive to focal geometry in the presence of a preplasma. This behavior is consistent with differences in interaction length and effective intensity at the critical surface between the two configurations. The sensitivity of the tightly focused f/1.5 configuration (zR≈ 5 μm) reflects the combined influence of thermal lensing and an extended preplasma, while the f/3 geometry (zR≈ 80 μm) remains comparatively robust. These results demonstrate a breakdown of conventional intensity scaling and identify focusing geometry as a critical control parameter for MeV electron and x-ray generation at petawatt powers. Implications for laser–plasma-based radiographic facilities are also discussed.
- Open Access
- 17 November 2025
- Published by Office of Scientific and Technical Information (OSTI)
Stable Beam Propagation for Efficient MeV Photon Dose Generation in Laser-Solid Interactions
- 17 November 2025
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessStable Beam Propagation for Efficient MeV Photon Dose Generation in Laser-Solid Interactions
- Open Access
- 1 March 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (3)
Characterization of laser-accelerated proton beams from a 0.5 kJ sub-picosecond laser for radiography applications
Laser-accelerated ion beams show promise for many applications, including high-resolution flash imaging of static or dynamic objects in next-generation radiography to probe materials and plasmas in extreme environments and inertial confinement fusion. To scale up ion beam production for radiography applications, we conducted experiments using sub-picosecond lasers up to 0.5 kJ at the OMEGA-EP facility to characterize proton beams from solid targets, primarily CH/CD sub-micron thin films from which ion beams were also used for static and dynamic radiography for the first time. For standalone sub-micron thin CH films, the highest detected proton energy is in the range of 72–97 MeV. Proton beams with highest energy near or above 60 MeV at full laser energy and similar beam profiles are also measured from low-density CD foams and flat CH foil target of micrometer-scale thickness. The ∼ 700–800 nm CH/CD foils achieve the highest ion yield among the targets tested. For sub-micron thin films, the laser prepulse can expand the target and lead to complex interactions, which is simulated using coupled hydrodynamic and two-step kinetic models. Simulations suggest the presence of a micrometer-scale preplasma plateau with near-critical density and further indicate that target normal sheath acceleration, electron heating from Relativistic transparency in the preplasma plateau, and background proton reflection from carbon ion front at the rear side contribute to the resulting proton spectrum from these sub-micron thin targets at various stages. These proton beams show strong potential for radiography and for production of secondary sources.
- 1 March 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (3)
Open AccessCharacterization of laser-accelerated proton beams from a 0.5 kJ sub-picosecond laser for radiography applications
Laser-accelerated ion beams show promise for many applications, including high-resolution flash imaging of static or dynamic objects in next-generation radiography to probe materials and plasmas in extreme environments and inertial confinement fusion. To scale up ion beam production for radiography applications, we conducted experiments using sub-picosecond lasers up to 0.5 kJ at the OMEGA-EP facility to characterize proton beams from solid targets, primarily CH/CD sub-micron thin films from which ion beams were also used for static and dynamic radiography for the first time. For standalone sub-micron thin CH films, the highest detected proton energy is in the range of 72–97 MeV. Proton beams with highest energy near or above 60 MeV at full laser energy and similar beam profiles are also measured from low-density CD foams and flat CH foil target of micrometer-scale thickness. The ∼ 700–800 nm CH/CD foils achieve the highest ion yield among the targets tested. For sub-micron thin films, the laser prepulse can expand the target and lead to complex interactions, which is simulated using coupled hydrodynamic and two-step kinetic models. Simulations suggest the presence of a micrometer-scale preplasma plateau with near-critical density and further indicate that target normal sheath acceleration, electron heating from Relativistic transparency in the preplasma plateau, and background proton reflection from carbon ion front at the rear side contribute to the resulting proton spectrum from these sub-micron thin targets at various stages. These proton beams show strong potential for radiography and for production of secondary sources.
- Open Access
- 1 December 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (12)
MeV x-ray production from a petawatt laser in the regime of a relativistically transparent preplasma, with applications to radiography
Bright sources of mega-electron volt (MeV) x-rays have many unique applications, including nuclear physics, radiation oncology, and imaging high areal density systems. High intensity lasers (>1018 W cm−2) incident on mm-thick metal targets can deliver MeV x-rays via the bremsstrahlung process, providing sources with ultrashort duration (∼ps) and small source size (∼100 μm). Here, we report on a reproducible regime of laser-driven MeV x-ray sources, where the x-ray dose can be further increased by 60% by coating the metal target with micrometers of plastic. High fidelity numerical simulations indicate that the interaction is a result of relativistic transparency in the preplasma. Though relativistic transparency is present in both cases, the greater sound speed and smaller ion inertia of the plastic target allow the laser to more deeply penetrate and couple more efficiently to electrons. Radiography with this system demonstrates a resolving power < 300 μm, important for imaging applications.
- 1 December 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (12)
Open AccessMeV x-ray production from a petawatt laser in the regime of a relativistically transparent preplasma, with applications to radiography
Bright sources of mega-electron volt (MeV) x-rays have many unique applications, including nuclear physics, radiation oncology, and imaging high areal density systems. High intensity lasers (>1018 W cm−2) incident on mm-thick metal targets can deliver MeV x-rays via the bremsstrahlung process, providing sources with ultrashort duration (∼ps) and small source size (∼100 μm). Here, we report on a reproducible regime of laser-driven MeV x-ray sources, where the x-ray dose can be further increased by 60% by coating the metal target with micrometers of plastic. High fidelity numerical simulations indicate that the interaction is a result of relativistic transparency in the preplasma. Though relativistic transparency is present in both cases, the greater sound speed and smaller ion inertia of the plastic target allow the laser to more deeply penetrate and couple more efficiently to electrons. Radiography with this system demonstrates a resolving power < 300 μm, important for imaging applications.
- Open Access
- 1 December 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (12)
Advances in laser-based bremsstrahlung x-ray sources. I. Optimizing laser-accelerated electrons
In this work, we have performed a suite of kinetic simulations of relativistic laser–plasma interaction under settings relevant to recent and planned experiments on a variety of laser systems. The goal of the study is to illuminate the physics of laser–target coupling and to provide guidance for how to optimize these sources for applications. It is shown that the production of relativistic electrons is maximized when conditions of relativistic induced transparency (RIT) in dense plasmas can be achieved over a large interaction volume at the time of arrival of most intense part of the laser pulse. RIT is shown to enhance both the numbers of relativistic electrons and the energies of the electrons, leading to an increased x-ray dose. A variety of approaches to enhancing laser–target coupling are considered. These include optimizing the effects of low-density pre-plasma (arising either from finite laser pedestal or from the use of foam coatings) and of modifying the laser focusing geometry to reduce effects of filamentation and self-focusing. Evidence of a novel approach to achieving stable laser propagation over distances of tens of micrometers in a plasma gradient is also presented. These conditions coincide with plasma and laser conditions explored in recent experiments on the Omega EP laser system and compare favorably with an analytic criterion for stable laser propagation in relativistically underdense plasma obtained from a nonlinear Wentzel–Kramers–Brillouin analysis.
- 1 December 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (12)
Open AccessAdvances in laser-based bremsstrahlung x-ray sources. I. Optimizing laser-accelerated electrons
In this work, we have performed a suite of kinetic simulations of relativistic laser–plasma interaction under settings relevant to recent and planned experiments on a variety of laser systems. The goal of the study is to illuminate the physics of laser–target coupling and to provide guidance for how to optimize these sources for applications. It is shown that the production of relativistic electrons is maximized when conditions of relativistic induced transparency (RIT) in dense plasmas can be achieved over a large interaction volume at the time of arrival of most intense part of the laser pulse. RIT is shown to enhance both the numbers of relativistic electrons and the energies of the electrons, leading to an increased x-ray dose. A variety of approaches to enhancing laser–target coupling are considered. These include optimizing the effects of low-density pre-plasma (arising either from finite laser pedestal or from the use of foam coatings) and of modifying the laser focusing geometry to reduce effects of filamentation and self-focusing. Evidence of a novel approach to achieving stable laser propagation over distances of tens of micrometers in a plasma gradient is also presented. These conditions coincide with plasma and laser conditions explored in recent experiments on the Omega EP laser system and compare favorably with an analytic criterion for stable laser propagation in relativistically underdense plasma obtained from a nonlinear Wentzel–Kramers–Brillouin analysis.
- Open Access
- 1 December 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (12)
Advances in laser-based bremsstrahlung x-ray sources. II. Laser pulse propagation and guiding in nonuniform plasma media in the presence of self-focusing
An analytic Wentzel–Kramers–Brillouin model is presented of Gaussian laser pulse propagation through plasma with a quadratic transverse density profile and an arbitrarily varying, longitudinal density gradient under conditions of nonlinear self-focusing. From these solutions, it is shown that in the absence of nonlinear self-focusing and transverse nonuniformity, for exponential pre-plasma density profiles, the use of a low density coating of the laser target with electron density n0∼11 ncr (e.g., a CH foam of density 35 mg/cm3 for 1-micron laser light) maximizes laser intensity at best focus. Also, under laser and plasma conditions relevant to recent experiments on high-power laser systems, conditions are obtained for a Gaussian laser pulse to propagate stably through the pre-plasma medium. Such conditions would be expected to enhance the production of relativistic electrons from laser-target coupling, providing a possible explanation for the observed increase in MeV photon dose and enabling applications such as laser-based MeV X-ray radiography.
- 1 December 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (12)
Open AccessAdvances in laser-based bremsstrahlung x-ray sources. II. Laser pulse propagation and guiding in nonuniform plasma media in the presence of self-focusing
An analytic Wentzel–Kramers–Brillouin model is presented of Gaussian laser pulse propagation through plasma with a quadratic transverse density profile and an arbitrarily varying, longitudinal density gradient under conditions of nonlinear self-focusing. From these solutions, it is shown that in the absence of nonlinear self-focusing and transverse nonuniformity, for exponential pre-plasma density profiles, the use of a low density coating of the laser target with electron density n0∼11 ncr (e.g., a CH foam of density 35 mg/cm3 for 1-micron laser light) maximizes laser intensity at best focus. Also, under laser and plasma conditions relevant to recent experiments on high-power laser systems, conditions are obtained for a Gaussian laser pulse to propagate stably through the pre-plasma medium. Such conditions would be expected to enhance the production of relativistic electrons from laser-target coupling, providing a possible explanation for the observed increase in MeV photon dose and enabling applications such as laser-based MeV X-ray radiography.
- Open Access
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Reduced-order model to approximate response matrices for filter stack spectrometers
We present a reduced-order model to calculate response matrices rapidly for filter stack spectrometers (FSSs). The reduced-order model allows response matrices to be built modularly from a set of pre-computed photon and electron transport and scattering calculations through various filter and detector materials. While these modular response matrices are not appropriate for high-fidelity analysis of experimental data, they encode sufficient physics to be used as a forward model in design optimization studies of FSSs, particularly for machine learning approaches that require sampling and testing a large number of FSS designs.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Open AccessReduced-order model to approximate response matrices for filter stack spectrometers
We present a reduced-order model to calculate response matrices rapidly for filter stack spectrometers (FSSs). The reduced-order model allows response matrices to be built modularly from a set of pre-computed photon and electron transport and scattering calculations through various filter and detector materials. While these modular response matrices are not appropriate for high-fidelity analysis of experimental data, they encode sufficient physics to be used as a forward model in design optimization studies of FSSs, particularly for machine learning approaches that require sampling and testing a large number of FSS designs.