Energy response characterization of current-mode MeV Cherenkov aerogel detectors
Open Access
- 1 June 2026
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (6)
Abstract
Current-mode Cherenkov aerogel detectors have been used to measure time resolved spectra of MeV radiographic x-ray sources and have been considered to replace gas Cherenkov systems. The simulations of the Cherenkov response of aerogel detectors have uncertainties in how to model the complex structure of aerogels. Data from three sites—the Idaho electron beam, the Los Alamos Site electron beam and microtron sources at Los Alamos—have been used to calibrate the relative energy response of 15 aerogels, varying in density from 10 to 430 mg/cm3, from incident electrons with energies from 1 to 12 MeV. Detector simulations need to introduce density variation in the aerogels to match the collected data.Keywords
Funding Information
- Los Alamos National Laboratory (89233218CNA000001)
- Sandia National Laboratories (DE-NA-0003525)
This publication has 27 references indexed in Scilit:
- Solid Cherenkov detector for studying nucleosynthesis in inertial confinement fusionReview of Scientific Instruments, 2020
- Characterization of the Mercury pulsed power x-ray source spectrum using multichannel density aerogel Cherenkov detectorsReview of Scientific Instruments, 2018
- Coarse spectral characterization of warm x-rays at the Z facility using a filtered thermoluminescent dosimeter arrayReview of Scientific Instruments, 2017
- Aerogel Cherenkov detector for characterizing the intense flash x-ray source, Cygnus, spectrumReview of Scientific Instruments, 2016
- Extended performance gas Cherenkov detector for gamma-ray detection in high-energy density experimentsReview of Scientific Instruments, 2014
- Three‐dimensional density measurements of ultra low density materials by X‐ray scatter using confocal micro X‐ray fluorescence spectroscopyX-Ray Spectrometry, 2012
- GEANT4 simulations of Cherenkov reaction history diagnosticsReview of Scientific Instruments, 2010
- Laser-Compton scattering from a 20 MeV electron beamNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- Aerogel Cherenkov counter for the BELLE detectorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2000
- Empirical tests and model of a silica aerogel Cherenkov detector for CEBAFNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1995