MWMary F. Wang

Mary F. Wang

*This is an algorithmically generated author record based on publicly available information.

Mary F. Wang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Complementary UV-MALDI and IR-MALDESI Imaging Expand Metabolomic Coverage in the 6-OHDA Rat Model of Parkinson’s Disease

    by Mary F. Wang, Reza Shariatgorji, Anna Nilsson, Ibrahim Kaya, Per Svenningsson, Per E. Andrén, David C. Muddiman

    In this study, we demonstrate the complementary strengths of FMP-10 (4-(Anthracen-9-yl)-2-fluoro-1-methylpyridin-1-ium iodide) on-tissue derivatization with UV-MALDI MSI and IR-MALDESI MSI without derivatization for small molecule analysis. These MSI approaches were applied to the striatum of rats administered 6-OHDA to induce dopaminergic neurodegeneration, modeling Parkinson's disease. UV-MALDI MSI with FMP-10 derivatization enhanced the detection of dopaminergic and serotonergic metabolites, revealing clear lesion-related effects. IR-MALDESI MSI, in turn, expanded the molecular coverage by detecting several hundred additional small molecules, including neurotransmitters, amino acids, and lipids. The complementary application of these ionization strategies broadened metabolomic coverage, highlighting their potential for broader disease-related studies.


  • Open Access

    Lipidomic signatures of CNS ischemic injury and their modulation by immunomodulatory hydrogels

    by Mary F. Wang, Yunxin Ouyang, Tatiana Segura, David C. Muddiman

    Ischemic injury in the central nervous system (CNS) triggers profound metabolic remodeling that influences inflammation, repair, and cellular survival.

  • Application and Characterization of Novel Mid-IR Glucoloop Laser for Mass Spectrometry Imaging and Small Molecule Screening

    by Seth M. Eisenberg, Emily R. Bruce, Sarah M. Ashbacher, Mary F. Wang, James W. Sawicki, Andrew J. Radosevich, Jon D. Williams, Gabriel Spühler, Andrei Selivanau, David C. Muddiman

    Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is an ambient ionization source often used for mass spectrometry imaging and screening of small molecules in solution by high throughput screening. A novel mid-IR laser, developed by Glucoloop (Ivy), was utilized to achieve 20 μm ablation spot sizes with high and reproducible signal across a variety of sample types, including brain and plant tissues, the primary focus of this proof-of-concept study. The laser was also used for detection of small molecule pharmaceuticals in aqueous solutions, showing high consistency (11% CV) and very low carryover between wells. These results highlight the potential of the Glucoloop laser system to enable high-resolution, high-sensitivity IR-MALDESI analyses across a broad range of biological sample types. Its performance supports further development for both imaging and high-throughput screening applications.


  • Optimizing neurotransmitter pathway detection by IR-MALDESI-MSI in mouse brain

    by Mary F. Wang, Yunxin Ouyang, Tatiana Segura, David C. Muddiman

    Mass spectrometry imaging (MSI) platforms such as infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) are advantageous for a variety of applications, including elucidating the localization of neurotransmitters (NTs) and related molecules with respect to ion abundance across a sample without the need for derivatization or organic matrix application. While IR-MALDESI-MSI conventionally uses a thin exogenous ice matrix to improve signal abundance, it has been previously determined that sucrose embedding without the ice matrix improves detection of lipid species in striatal, coronal mouse brain sections. This work considers components of this workflow to determine the optimal sample preparation and matrix to enhance the detection of NTs and their related metabolites in coronal sections from the striatal region of the mouse brain. The discoveries herein will enable more comprehensive follow-on studies for the investigation of NTs to enrich biological pathways and interpretation related to neurodegenerative diseases and ischemic stroke. Graphical abstract


  • Comparative analysis of sucrose-embedding for whole-body zebrafish MSI by IR-MALDESI

    by Mary F. Wang, Morgan M. Ritter, Seth W. Kullman, David C. Muddiman

    Infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging (IR-MALDESI) conventionally utilizes fresh-frozen biological tissues with an ice matrix to improve the detection of analytes. Sucrose-embedding with paraformaldehyde fixation has demonstrated feasibility as an alternative matrix for analysis by IR-MALDESI by preserving tissue features and enhancing ionization of lipids. However, investigating multi-organ systems provides broader context for a biological study and can elucidate more information about a disease state as opposed to a single organ. Danio rerio, or zebrafish, are model organisms for various disease states and can be imaged as a multi-organ sample to analyze morphological and metabolomic preservation as a result of sample preparation. Herein, whole-body zebrafish were imaged to compare sucrose-embedding with paraformaldehyde fixation against conventional fresh-frozen sample preparation. Serial sections were analyzed with and without an ice matrix to evaluate if sucrose functions as an alternative energy-absorbing matrix for IR-MALDESI applications across whole-body tissues. The resulting four conditions were compared in terms of total putative lipid annotations and category diversity, coverage across the entire m/z range, and ion abundance. Ultimately, sucrose-embedded zebrafish had an increase in putative lipid annotations for the combination of putative annotations with and without the application of an ice matrix relative to fresh-frozen tissues which require the application of an ice matrix. Upon the use of an ice matrix, a greater number of high mass putative lipid annotations (e.g., glycerophospholipids, glycerolipids, and sphingolipids) were identified. Conversely, without an ice matrix, sucrose-embedded sections elucidated more putative annotations in lower molecular weight lipids, including fatty acyls and sterol lipids. Similar to the mouse brain model, sucrose-embedding increased putative lipid annotation and abundance for whole-body zebrafish. Graphical abstract


  • Lipidomic Analysis of Mouse Brain to Evaluate the Efficacy and Preservation of Different Tissue Preparatory Techniques by IR-MALDESI-MSI

    by Mary F. Wang, Alexandria L. Sohn, Juhi Samal, Kevin Erning, Tatiana Segura, David C. Muddiman

    Numerous preparatory methods have been developed to preserve the cellular and structural integrity of various biological tissues for different -omics studies. Herein, two preparatory methods for mass spectrometry imaging (MSI) were evaluated, fresh-frozen and sucrose-embedded, paraformaldehyde (PFA) fixed, in terms of ion abundance, putative lipid identifications, and preservation of analyte spatial distributions. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI)-MSI was utilized to compare the preparatory methods of interest with and without the use of the conventional ice matrix. There were 2.5-fold and 1.6-fold more lipid species putatively identified in positive- and negative-ion modes, respectively, for sucrose-embedded, PFA-fixed tissues without an ice matrix relative to the current IR-MALDESI-MSI gold-standard, fresh-frozen tissue preparation with an exogenous ice matrix. Furthermore, sucrose-embedded tissues demonstrated improved spatial distribution of ions resulting from the cryo-protective property of sucrose and paraformaldehyde fixation. Evidence from these investigations supports sucrose-embedding without ice matrix as an alternative preparatory technique for IR-MALDESI-MSI.


  • Open Access

    Time of acquisition and high spatial resolution mass spectrometry imaging

    by Mary F. Wang, Alena N. Joignant, Alexandria L. Sohn, Kenneth P. Garrard, David C. Muddiman

    The field of mass spectrometry imaging (MSI) is constantly evolving to analyze a diverse array of biological systems. A common goal is the need to resolve cellular and subcellular heterogeneity with high spatial resolution. As the field continues to progress towards high spatial resolution, other parameters must be considered when developing a practical method. Here, we discuss the impacts of high spatial resolution on the time of acquisition and the associated implications they have on an MSI analysis (e.g., area of the region of interest). This work presents a brief tutorial serving to evaluate high spatial resolution MSI relative to time of acquisition and data file size.