Julien Carlier
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Julien Carlier has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Bertrand Nongaillard
Univ. Polytechnique Hauts-de-France, CNRS, Univ. Lille, UMR 8520 - IEMN - Institut d'Electronique de Microélectronique et de Nanotechnologie , F-59313 Valenciennes, France
4 shared publications - Malika Toubal
Univ. Polytechnique Hauts-de-France, Univ. Lille, CNRS, Centrale Lille, UMR 8520 - IEMN- Institut d’Electronique de Microélectronique et de Nanotechnologie, F-59000 Lille, France
4 shared publications - Nikolay Smagin
Institut d’Électronique de Microélectronique et de Nanotechnologie (IEMN), UMR CNRS 8520, Université Polytechnique Hauts-de-France, CNRS, Université de Lille, 59313 Valenciennes, France
3 shared publications - Pierre Campistron
Univ. Polytechnique Hauts-de-France, Univ. Lille, CNRS, Centrale Lille, UMR 8520 - IEMN- Institut d’Electronique de Microélectronique et de Nanotechnologie, F-59000 Lille, France
3 shared publications - Ibrahim Zaaroura
Department of Mechanics, LAMIH, UMR CNRS 8201, Polytechnic University Hauts-de-France, Valenciennes, France
2 shared publications Souad Harmand
Department of Mechanics, LAMIH, UMR CNRS 8201, Polytechnic University Hauts-de-France, Valenciennes, France
2 shared publications
Latest Publications
- Open Access
C-Axis Oriented LiNbO3 Thin Film Grown by Chemical Beam Epitaxy for Surface Acoustic Wave Device Applications
High-frequency surface acoustic wave (SAW) devices require piezoelectric thin films combining strong electromechanical coupling, high acoustic velocity, and compatibility with scalable fabrication. Lithium niobate (LiNbO3) is a promising material, but the growth of high-quality thin films remains challenging because of lithium volatility and process-control issues. In this work, chemical beam epitaxy (CBE) was investigated as an alternative route for the deposition of c-axis-oriented LiNbO3 thin films on C-plane sapphire at a relatively low growth temperature of 400 °C. Structural characterization confirmed high crystalline quality, with clear (006) and (0012) XRD reflections and a rocking-curve full width at half maximum of 0.04°. To evaluate acoustic performance, a SAW delay line and a one-port resonator were fabricated on 350 nm thick films using e-beam lithography. The devices operated in the 1–3 GHz range and exhibited electromechanical coupling factors of about 0.3% for the Rayleigh mode at 1.7 GHz and 3% for the Sezawa mode at 2.75 GHz. Propagation velocities ranged from 5094 to 8250 m/s, and the Rayleigh-mode resonator quality factor reached about 500. These results demonstrate the feasibility of CBE-grown LiNbO3 films for SAW device applications.
Open AccessC-Axis Oriented LiNbO3 Thin Film Grown by Chemical Beam Epitaxy for Surface Acoustic Wave Device Applications
High-frequency surface acoustic wave (SAW) devices require piezoelectric thin films combining strong electromechanical coupling, high acoustic velocity, and compatibility with scalable fabrication. Lithium niobate (LiNbO3) is a promising material, but the growth of high-quality thin films remains challenging because of lithium volatility and process-control issues. In this work, chemical beam epitaxy (CBE) was investigated as an alternative route for the deposition of c-axis-oriented LiNbO3 thin films on C-plane sapphire at a relatively low growth temperature of 400 °C. Structural characterization confirmed high crystalline quality, with clear (006) and (0012) XRD reflections and a rocking-curve full width at half maximum of 0.04°. To evaluate acoustic performance, a SAW delay line and a one-port resonator were fabricated on 350 nm thick films using e-beam lithography. The devices operated in the 1–3 GHz range and exhibited electromechanical coupling factors of about 0.3% for the Rayleigh mode at 1.7 GHz and 3% for the Sezawa mode at 2.75 GHz. Propagation velocities ranged from 5094 to 8250 m/s, and the Rayleigh-mode resonator quality factor reached about 500. These results demonstrate the feasibility of CBE-grown LiNbO3 films for SAW device applications.
- 27 September 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (10) , 105967
Indirect nanoscale characterization of polymer photoresist wetting using ultra-high frequency acoustic waves
The wetting of surfaces with patterns in the order of a hundred nanometers is often a complex phenomenon to analyze and control. In the semiconductor industry, whether it is during the surface cleaning steps or the deposition of the protective mask (photosensitive liquid resin that is then cross-linked), the conformity of the deposit of the liquid layer on the patterned surface must be perfect or else the functionality of the targeted electronic component will be compromised. Thus, understanding the surface wetting of these liquids allows the implementation of optimized processes. In this paper, we present a method of indirect wetting characterization of a photoresist based on ultra-high frequency (# GHz) acoustic waves. This resin is a commercial product called GKR 4602 (belonging to the KrF series of positive photoresists), which is coated in two different ways: either directly onto the surface of a patterned silicon wafer, or after application of a solvent, Propylene Glycol Ethyl Ether (PGEE), which then acts as a pre-wetting layer. The patterned wafer, playing the role of electrical insulation (Deep Trench Isolation, DTI) are 200 nm wide, deep trenches with a high aspect ratio (> 50). The originality of this paper lies in the validation of the acoustic characterization by direct observation of the wetting of the cross-linked resin. To do so, we used a FIB (Focused Ion Beam) microscope which allowed us to make cuts and capture localized images of the wetting state of the photoresist. Moreover, all the results obtained (resins and patterned silicon surfaces) are directly from the microelectronics industry (STMicroelectronics), showing that our method is fully compatible with an industrial approach.
- 27 September 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (10) , 105967
Indirect nanoscale characterization of polymer photoresist wetting using ultra-high frequency acoustic waves
The wetting of surfaces with patterns in the order of a hundred nanometers is often a complex phenomenon to analyze and control. In the semiconductor industry, whether it is during the surface cleaning steps or the deposition of the protective mask (photosensitive liquid resin that is then cross-linked), the conformity of the deposit of the liquid layer on the patterned surface must be perfect or else the functionality of the targeted electronic component will be compromised. Thus, understanding the surface wetting of these liquids allows the implementation of optimized processes. In this paper, we present a method of indirect wetting characterization of a photoresist based on ultra-high frequency (# GHz) acoustic waves. This resin is a commercial product called GKR 4602 (belonging to the KrF series of positive photoresists), which is coated in two different ways: either directly onto the surface of a patterned silicon wafer, or after application of a solvent, Propylene Glycol Ethyl Ether (PGEE), which then acts as a pre-wetting layer. The patterned wafer, playing the role of electrical insulation (Deep Trench Isolation, DTI) are 200 nm wide, deep trenches with a high aspect ratio (> 50). The originality of this paper lies in the validation of the acoustic characterization by direct observation of the wetting of the cross-linked resin. To do so, we used a FIB (Focused Ion Beam) microscope which allowed us to make cuts and capture localized images of the wetting state of the photoresist. Moreover, all the results obtained (resins and patterned silicon surfaces) are directly from the microelectronics industry (STMicroelectronics), showing that our method is fully compatible with an industrial approach.
- 6 March 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (10) , 102201
One-channel time reversal focusing of ultra-high frequency acoustic waves on a MEMS
This Letter reports on a work performed to fabricate and characterize a silicon micro-machined cavity dedicated to micro-resolution Ultra-High Frequency imaging in microfluidics and microbiological applications using one-channel time reversal. Time reversal provides the means to spatially and temporally localize elastic energy on a receiver. Here, the arrays of zinc oxide micro transducers are coupled with a 400 μm thick silicon wafer containing micromachined structures for acoustical field confinement. Characterization of the diffused acoustic field and time-reversal retro-focusing are reported. The transducers are wideband in the 0.2–2 GHz range with a central frequency of 0.9 GHz.
- 6 March 2023
- Published by AIP Publishing in Applied Physics Letters
- Vol. 122 (10) , 102201
One-channel time reversal focusing of ultra-high frequency acoustic waves on a MEMS
This Letter reports on a work performed to fabricate and characterize a silicon micro-machined cavity dedicated to micro-resolution Ultra-High Frequency imaging in microfluidics and microbiological applications using one-channel time reversal. Time reversal provides the means to spatially and temporally localize elastic energy on a receiver. Here, the arrays of zinc oxide micro transducers are coupled with a 400 μm thick silicon wafer containing micromachined structures for acoustical field confinement. Characterization of the diffused acoustic field and time-reversal retro-focusing are reported. The transducers are wideband in the 0.2–2 GHz range with a central frequency of 0.9 GHz.
- 22 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (9) , 8772-8780
Toward a Reliable Estimation of Fluid Concentration Using High Frequency Acoustic Waves: A Machine Learning Approach
Using acoustic waves to estimate fluid concentration is a promising technology due to its practicality and non-intrusive aspect, especially for medical applications. The existing approaches are exclusively based on the correlation between the reflection coefficient and the concentration. However, these techniques are limited by the high sensitivity of the reflection coefficient to environment conditions changes, even slight ones. This introduces inaccuracies that cannot be tolerated in medical applications. This paper proposed a deep learning model, Fluid Concentration Estimation Convolutional Neural Network (FCE-CNN), to estimate fluid concentration. Instead of using only the reflection coefficient, we train our model to detect concentration-related patterns based on the whole received acoustic signal. FCE-CNN shows promising results that overcome the state-of-the-art limitations. Specifically, our model that is able to estimate fluid concentration with 98.5% accuracy using ultra high frequency acoustic waves.
- 22 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (9) , 8772-8780
Toward a Reliable Estimation of Fluid Concentration Using High Frequency Acoustic Waves: A Machine Learning Approach
Using acoustic waves to estimate fluid concentration is a promising technology due to its practicality and non-intrusive aspect, especially for medical applications. The existing approaches are exclusively based on the correlation between the reflection coefficient and the concentration. However, these techniques are limited by the high sensitivity of the reflection coefficient to environment conditions changes, even slight ones. This introduces inaccuracies that cannot be tolerated in medical applications. This paper proposed a deep learning model, Fluid Concentration Estimation Convolutional Neural Network (FCE-CNN), to estimate fluid concentration. Instead of using only the reflection coefficient, we train our model to detect concentration-related patterns based on the whole received acoustic signal. FCE-CNN shows promising results that overcome the state-of-the-art limitations. Specifically, our model that is able to estimate fluid concentration with 98.5% accuracy using ultra high frequency acoustic waves.
- 5 May 2021
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 51 (4) , 1136-1144
Modeling and Prediction of the Dynamic Viscosity of Nanofluids by a Homogenization Method
- 5 May 2021
- Published by Springer Nature in Brazilian Journal of Physics
- Vol. 51 (4) , 1136-1144
Modeling and Prediction of the Dynamic Viscosity of Nanofluids by a Homogenization Method
- Open Access
- 15 November 2012
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 112 (10) , 104908
Characterization of the state of a droplet on a micro-textured silicon wafer using ultrasound
In this work, we propose acoustic characterization as a new method to probe wetting states on a superhydrophobic surface. The analysis of the multiple reflections of a longitudinal acoustic wave from solid-liquid and solid-vapor interfaces enables to distinguish between the two well known Cassie-Baxter and Wenzel wetting configurations. The phenomenon is investigated experimentally on silicon micro-pillars superhydrophobic surfaces and numerically using a finite difference time domain method. Numerical calculations of reflection coefficients show a good agreement with experimental measurements, and the method appears as a promising alternative to optical measurement methods.
- 15 November 2012
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 112 (10) , 104908
Open AccessCharacterization of the state of a droplet on a micro-textured silicon wafer using ultrasound
In this work, we propose acoustic characterization as a new method to probe wetting states on a superhydrophobic surface. The analysis of the multiple reflections of a longitudinal acoustic wave from solid-liquid and solid-vapor interfaces enables to distinguish between the two well known Cassie-Baxter and Wenzel wetting configurations. The phenomenon is investigated experimentally on silicon micro-pillars superhydrophobic surfaces and numerically using a finite difference time domain method. Numerical calculations of reflection coefficients show a good agreement with experimental measurements, and the method appears as a promising alternative to optical measurement methods.
- 1 January 2012
- Published by AIP Publishing in AIP Conference Proceedings
- p. 675-678
A LiNbO3 ultrasonic phased array transducer of more than 100 MHz
High-frequency ultrasonic transducer arrays are essential for high resolution imaging in clinical analysis and Non-Destructive Evaluation (NDE). However, the structure design and fabrication of the kerfed ultrasonic array is quite challenging when very high frequency (≥ 100 MHz) is required. Inductively Coupled Plasma (ICP) deep etching process is used to etch 36°/Y-cut lithium niobate (LiNbO3) crystals. Furthermore, a finite element tool, COMSOL, is employed to calculate the electrical properties of the arrays, including crosstalk effect and electrical impedance. At last, arrays with a pitch of 40 μm are fabricated and characterized by a network analyzer. The measured results agree well with the theoretical predictions.
- 1 January 2012
- Published by AIP Publishing in AIP Conference Proceedings
- p. 675-678
A LiNbO3 ultrasonic phased array transducer of more than 100 MHz
High-frequency ultrasonic transducer arrays are essential for high resolution imaging in clinical analysis and Non-Destructive Evaluation (NDE). However, the structure design and fabrication of the kerfed ultrasonic array is quite challenging when very high frequency (≥ 100 MHz) is required. Inductively Coupled Plasma (ICP) deep etching process is used to etch 36°/Y-cut lithium niobate (LiNbO3) crystals. Furthermore, a finite element tool, COMSOL, is employed to calculate the electrical properties of the arrays, including crosstalk effect and electrical impedance. At last, arrays with a pitch of 40 μm are fabricated and characterized by a network analyzer. The measured results agree well with the theoretical predictions.