MTMalika Toubal

Malika Toubal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Malika Toubal has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Julien Carlier

    Institut d’Électronique de Microélectronique et de Nanotechnologie (IEMN), UMR CNRS 8520, Université Polytechnique Hauts-de-France, CNRS, Université de Lille, 59313 Valenciennes, France

    4 shared publications
  • Bertrand Nongaillard

    Univ. Polytechnique Hauts-de-France, CNRS, Univ. Lille, UMR 8520 - IEMN - Institut d'Electronique de Microélectronique et de Nanotechnologie , F-59313 Valenciennes, France

    2 shared publications
  • Ibrahim Zaaroura

    Department of Mechanics, LAMIH, UMR CNRS 8201, Polytechnic University Hauts-de-France, Valenciennes, France

    2 shared publications
  • Nikolay Smagin

    Institut d’Électronique de Microélectronique et de Nanotechnologie (IEMN), UMR CNRS 8520, Université Polytechnique Hauts-de-France, CNRS, Université de Lille, 59313 Valenciennes, France

    2 shared publications
  • Pierre Campistron

    Univ. Polytechnique Hauts-de-France, Univ. Lille, CNRS, Centrale Lille, UMR 8520 - IEMN- Institut d’Electronique de Microélectronique et de Nanotechnologie, F-59000 Lille, France

    2 shared publications
  • Souad Harmand

    Department of Mechanics, LAMIH, UMR CNRS 8201, Polytechnic University Hauts-de-France, Valenciennes, France

    2 shared publications

Latest Publications

  • Indirect nanoscale characterization of polymer photoresist wetting using ultra-high frequency acoustic waves

    by A Salhab, J Carlier, M Toubal, D Troadec, P Garnier, T Mercadier, P Campistron, V Thomy

    The wetting of surfaces with patterns in the order of a hundred nanometers is often a complex phenomenon to analyze and control. In the semiconductor industry, whether it is during the surface cleaning steps or the deposition of the protective mask (photosensitive liquid resin that is then cross-linked), the conformity of the deposit of the liquid layer on the patterned surface must be perfect or else the functionality of the targeted electronic component will be compromised. Thus, understanding the surface wetting of these liquids allows the implementation of optimized processes. In this paper, we present a method of indirect wetting characterization of a photoresist based on ultra-high frequency (# GHz) acoustic waves. This resin is a commercial product called GKR 4602 (belonging to the KrF series of positive photoresists), which is coated in two different ways: either directly onto the surface of a patterned silicon wafer, or after application of a solvent, Propylene Glycol Ethyl Ether (PGEE), which then acts as a pre-wetting layer. The patterned wafer, playing the role of electrical insulation (Deep Trench Isolation, DTI) are 200 nm wide, deep trenches with a high aspect ratio (> 50). The originality of this paper lies in the validation of the acoustic characterization by direct observation of the wetting of the cross-linked resin. To do so, we used a FIB (Focused Ion Beam) microscope which allowed us to make cuts and capture localized images of the wetting state of the photoresist. Moreover, all the results obtained (resins and patterned silicon surfaces) are directly from the microelectronics industry (STMicroelectronics), showing that our method is fully compatible with an industrial approach.


  • One-channel time reversal focusing of ultra-high frequency acoustic waves on a MEMS

    by H. Dahmani, N. Smagin, P. Campistron, J. Carlier, M. Toubal, B. Nongaillard

    This Letter reports on a work performed to fabricate and characterize a silicon micro-machined cavity dedicated to micro-resolution Ultra-High Frequency imaging in microfluidics and microbiological applications using one-channel time reversal. Time reversal provides the means to spatially and temporally localize elastic energy on a receiver. Here, the arrays of zinc oxide micro transducers are coupled with a 400 μm thick silicon wafer containing micromachined structures for acoustical field confinement. Characterization of the diffused acoustic field and time-reversal retro-focusing are reported. The transducers are wideband in the 0.2–2 GHz range with a central frequency of 0.9 GHz.


  • Toward a Reliable Estimation of Fluid Concentration Using High Frequency Acoustic Waves: A Machine Learning Approach

    by Venu Babu Thati, Ibrahim Zaaroura, Malika Toubal, Nikolay Smagin, Souad Harmand, Julien Carlier, Ihsen Alouani

    Using acoustic waves to estimate fluid concentration is a promising technology due to its practicality and non-intrusive aspect, especially for medical applications. The existing approaches are exclusively based on the correlation between the reflection coefficient and the concentration. However, these techniques are limited by the high sensitivity of the reflection coefficient to environment conditions changes, even slight ones. This introduces inaccuracies that cannot be tolerated in medical applications. This paper proposed a deep learning model, Fluid Concentration Estimation Convolutional Neural Network (FCE-CNN), to estimate fluid concentration. Instead of using only the reflection coefficient, we train our model to detect concentration-related patterns based on the whole received acoustic signal. FCE-CNN shows promising results that overcome the state-of-the-art limitations. Specifically, our model that is able to estimate fluid concentration with 98.5% accuracy using ultra high frequency acoustic waves.


  • Modeling and Prediction of the Dynamic Viscosity of Nanofluids by a Homogenization Method

    by Ibrahim Zaaroura, Hilal Reda, Fabrice Lefebvre, Julien Carlier, Malika Toubal, Souad Harmand, Bertrand Nongaillard, Hassan Lakiss