Jessica Cristina Tironi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jessica Cristina Tironi has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Juan Francisco De Paz
Expert Systems and Applications Laboratory, University of Salamanca, Salamanca, Spain
2 shared publications - Rafael Silfarney Alves Araújo
Universidade do Vale do Itajaí Itajaí, Santa Catarina, BRA
2 shared publications - Renata Coelho Borges
Universidade Tecnológica Federal do Paraná
2 shared publications - Valderi Reis Quietinho Leithardt
University Institute of Lisbon (ISCTE-IUL), ISTAR, Lisbon, Portugal
2 shared publications - Wemerson Delcio Parreira
Polytechnic School, Faculty of Electrical Engineering Pontifical Catholic University of Campinas Campinas Brazil
2 shared publications
Latest Publications
- Open Access
- 2 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (5) , 3199
Analysis of Adaptive Algorithms Based on Least Mean Square Applied to Hand Tremor Suppression Control
The increase in life expectancy, according to the World Health Organization, is a fact, and with it rises the incidence of age-related neurodegenerative diseases. The most recurrent symptoms are those associated with tremors resulting from Parkinson’s disease (PD) or essential tremors (ETs). The main alternatives for the treatment of these patients are medication and surgical intervention, which sometimes have restrictions and side effects. Through computer simulations in Matlab software, this work investigates the performance of adaptive algorithms based on least mean squares (LMS) to suppress tremors in upper limbs, especially in the hands. The signals resulting from pathological hand tremors, related to PD, present components at frequencies that vary between 3 Hz and 6 Hz, with the more significant energy present in the fundamental and second harmonics, while physiological hand tremors, referred to ET, vary between 4 Hz and 12 Hz. We simulated and used these signals as reference signals in adaptive algorithms, filtered-x least mean square (Fx-LMS), filtered-x normalized least mean square (Fx-NLMS), and a hybrid Fx-LMS–NLMS purpose. Our results showed that the vibration control provided by the Fx-LMS–LMS algorithm is the most suitable for physiological tremors. For pathological tremors, we used a proposed algorithm with a filtered sinusoidal input signal, Fsinx-LMS, which presented the best results in this specific case.
- 2 March 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (5) , 3199
Open AccessAnalysis of Adaptive Algorithms Based on Least Mean Square Applied to Hand Tremor Suppression Control
The increase in life expectancy, according to the World Health Organization, is a fact, and with it rises the incidence of age-related neurodegenerative diseases. The most recurrent symptoms are those associated with tremors resulting from Parkinson’s disease (PD) or essential tremors (ETs). The main alternatives for the treatment of these patients are medication and surgical intervention, which sometimes have restrictions and side effects. Through computer simulations in Matlab software, this work investigates the performance of adaptive algorithms based on least mean squares (LMS) to suppress tremors in upper limbs, especially in the hands. The signals resulting from pathological hand tremors, related to PD, present components at frequencies that vary between 3 Hz and 6 Hz, with the more significant energy present in the fundamental and second harmonics, while physiological hand tremors, referred to ET, vary between 4 Hz and 12 Hz. We simulated and used these signals as reference signals in adaptive algorithms, filtered-x least mean square (Fx-LMS), filtered-x normalized least mean square (Fx-NLMS), and a hybrid Fx-LMS–NLMS purpose. Our results showed that the vibration control provided by the Fx-LMS–LMS algorithm is the most suitable for physiological tremors. For pathological tremors, we used a proposed algorithm with a filtered sinusoidal input signal, Fsinx-LMS, which presented the best results in this specific case.
- Open Access
- 6 February 2023
- Published by MDPI AG in Preprints.org
Analysis of Adaptive Algorithms Based on Least-Mean-Square Applied to Hand Tremors Suppression Control
The increase in life expectancy, according to the World Health Organization, is a fact, and with it rises the incidence of age-related neurodegenerative diseases. The most recurrent symptoms are those associated with tremors resulting from Parkinson's Disease (PD) or Essential Tremors (ET). The main alternatives for the treatment of these patients are medication and surgical intervention, which sometimes have restrictions and side effects. Through computer simulations in Matlab software, this work investigates the performance of adaptive algorithms based on least mean squares (LMS) to suppress tremors in upper limbs, especially in the hands. The signals resulting from pathological hand tremors, related to PD, present components at frequencies that vary between 3~Hz and 6~Hz, with the more significant energy present in the fundamental and second harmonics, while physiological hand tremors, referred to as ET, vary between 4~Hz and 12~Hz. We simulated and used these signals as reference signals in adaptive algorithms, Filtered-x Least Mean Square (Fx-LMS), Filtered-x Normalized Least Mean Square (Fx-NLMS), and a hybrid Fx-LMS\&NLMS purpose. Our results showed that the vibration control provided by the Fx-LMS\&LMS algorithm is the most suitable for physiological tremors. For pathological tremors, we have used a proposed algorithm with a filtered sinusoidal input signal, Fsinx-LMS, which presented the best results in this specific case.
- 6 February 2023
- Published by MDPI AG in Preprints.org
Open AccessAnalysis of Adaptive Algorithms Based on Least-Mean-Square Applied to Hand Tremors Suppression Control
The increase in life expectancy, according to the World Health Organization, is a fact, and with it rises the incidence of age-related neurodegenerative diseases. The most recurrent symptoms are those associated with tremors resulting from Parkinson's Disease (PD) or Essential Tremors (ET). The main alternatives for the treatment of these patients are medication and surgical intervention, which sometimes have restrictions and side effects. Through computer simulations in Matlab software, this work investigates the performance of adaptive algorithms based on least mean squares (LMS) to suppress tremors in upper limbs, especially in the hands. The signals resulting from pathological hand tremors, related to PD, present components at frequencies that vary between 3~Hz and 6~Hz, with the more significant energy present in the fundamental and second harmonics, while physiological hand tremors, referred to as ET, vary between 4~Hz and 12~Hz. We simulated and used these signals as reference signals in adaptive algorithms, Filtered-x Least Mean Square (Fx-LMS), Filtered-x Normalized Least Mean Square (Fx-NLMS), and a hybrid Fx-LMS\&NLMS purpose. Our results showed that the vibration control provided by the Fx-LMS\&LMS algorithm is the most suitable for physiological tremors. For pathological tremors, we have used a proposed algorithm with a filtered sinusoidal input signal, Fsinx-LMS, which presented the best results in this specific case.