ADAlice Dudle

Alice Dudle

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alice Dudle has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A simple personalised prediction model for hip fracture risk based on mechanistic parameters

    by Christina Wapp, Yvan Gugler, Paula Cameron, Alice Dudle, Daniela Frauchiger, Maria Papageorgiou, Emmanuel Biver, Serge Ferrari, Kurt Lippuner, Philippe Zysset

    Fragility hip fractures in older adults are a major burden for the individual and the society, as they result in increased morbidity, mortality and substantial health care expenditure. Most fragility hip fractures are caused by falls, resulting in an impact on the postero-lateral aspect of the hip, inducing a force that exceeds the femoral bone strength. The risk of fracture depends on the rate of falling, the fall-induced impact force, and the femoral bone strength. This article presents the framework of a novel fragility hip fracture risk calculator based on a combined mechanistic and stochastic modelling approach. The model integrates the stochastic aspects of a fall and its dynamics together with a 1D mechanical model predicting the impact force in the hip to calculate a one-year absolute fracture risk. The required input parameters are based on QCT images, but can be substituted with more accessible anthropometric and densitometric data. To demonstrate how the parameters are extracted from clinical data and how the model is calibrated, data from the AFFIRM-CT cohort were used. A sensitivity analysis was conducted, confirming that the fall rate, the trochanteric soft tissue thickness and the bone strength are the dominating parameters influencing the risk of fragility hip fractures. Furthermore, output variables such as the predicted impact velocity and impact force aligned well with experimental data. Thus, the model is able to reflect observations from empirical data, indicating that it can capture the intrinsic aspects that define the risk of fragility hip fractures.

  • Open Access

    Core-shell Particles with Tailored Magnetic Susceptibility for Signal-efficient Magnetic Resonance Imaging of Granular Systems

    by Stefan Benders, Jens P. Metzger, Mathieu Suter, Alice Dudle, Jenifer Nussbaum, Simon P. Gross, Maria Raquel Serial, Christoph R. Müller, Klaas Paul Pruessmann, Alexander Penn

    Magnetic Resonance Imaging (MRI) has been recently applied to decipher the complex flow of dry granular materials, which play an important role in a variety of chemical engineering applications. In these materials, the short apparent transverse relaxation time of the constituent grains, T2*, leads to rapid signal decay and hence limits the choice of suitable pulse sequences. While oil-rich agricultural seeds and oil-filled core-shell particles containing substantial amounts of liquids have been used to generate MRI signals, these particles still suffer from T2* values much shorter than the transverse relaxation time T2 of the contained liquid. This work investigates the effect of magnetic susceptibility on T2* through numerical simulations and experiments. Numerical results demonstrate that matching the magnetic susceptibility of the particles, χp, to that of the air between them, χair, reduces dipolar magnetic field inhomogeneities, theoretically enabling T2* = T2. We also found that common imperfections in core-shell particles — such as asphericity, non-concentricity of core and shell, and uneven shell thickness — cause significant field inhomogeneities. These inhomogeneities can only be mitigated if both the core and shell materials have a magnetic susceptibility matching that of air. Based on these findings, we designed and manufactured core-shell particles with doped cyclooctane~(CO) encapsulated in doped gelatin with χcore ~= χshell ~= χair. These particles exhibited a T2* of 3.84 ms, more than twice that of previously available materials, thus improving the signal-to-noise ratio and enhancing pulse sequence flexibility. This advancement opens up new possibilities for applications in engineering and the study of granular physics.

  • Open Access

    Accuracy and Robustness of Bone Volume Fraction Assessment by Photon-Counting, Dual-Energy, and Quantitative CT using Micro-CT as Standard of Reference

    by Patrik Wili, Dominic Gascho, Alice Dudle, Roy P. Marcus, Daniel Nanz, Michael Thali, Philippe Zysset

    Purpose: We aimed to quantitatively compare different computed tomography (CT)-based bone volume fraction (BV/TV) measurements. We hypothesize that phantom-less measurement using virtual monochromatic images (VMI) reconstructed form dual-energy CT (DECT) or photon counting CT (PCT) is less affected by tissue variations in trabecular bone than quantitative CT (QCT) and that PCT allows measurements with a lower radiation dose. Method: The BV/TV of bovine trabecular bone samples were measured using four CT scanning methods. Eight different measurements were compared using three soft tissue substitutes (air, saline solution, and fat) to investigate its effect on BV/TV estimation. For this purpose, the samples’ bone marrow was removed and replaced with one of the three substitutes in succession for CT scanning. For QCT, a standard bone phantom was used to derive BV/TV form CT values. While DECT- and PCT-based measurements were based on a system of energy-dependent equations established by reconstructing VMIs for specific photon energies. T-test, ANOVA tests and pairwise comparison were performed using the micro-CT (µCT) measurements as reference standard. Results: QCT showed a significant difference between the fat, saline solution, and air. DECT and especially PCT showed no differences between the substitutes. PCT showed no significant differences between radiation doses. Conclusion: Our results highlight the complexity of BV/TV measurements and emphasize the impact of the trabecular bone components on measurement accuracy. Despite these challenges, VMIs from “low” dose PCT provide a reliable alternative to standard QCT. They have the potential to improve the estimation of bone conditions, as well offering valuable insights for clinical, and forensic applications.


  • Open Access

    Asynchronous calibration of a CT scanner for bone mineral density estimation: sources of error and correction

    by Alice Dudle, Michael Ith, Rainer Egli, Johannes Heverhagen, Yvan Gugler, Christina Wapp, Daniela A Frauchiger, Kurt Lippuner, Christian Jackowski, Philippe Zysset

    The estimation of BMD with CT scans requires a calibration method, usually based on a phantom. In asynchronous calibration, the phantom is scanned separately from the patient. A standardized acquisition protocol must be used to avoid variations between patient and phantom. However, variations can still be induced, for example, by temporal fluctuations or patient characteristics. Based on the further use of 739 forensic and 111 clinical CT scans, this study uses the proximal femur BMD value (“total hip”) to assess asynchronous calibration accuracy, using in-scan calibration as ground truth. It identifies the parameters affecting the calibration accuracy and quantifies their impact. For time interval and table height, the impact was measured by calibrating the CT scan twice (once using the phantom scan with closest acquisition parameters and once using a phantom scan with standard values) and comparing the calibration accuracy. For other parameters such as body weight, the impact was measured by computing a linear regression between parameter values and calibration accuracy. Finally, this study proposes correction methods to reduce the effect of these parameters and improve the calibration accuracy. The BMD error of the asynchronous calibration, using the phantom scan with the closest acquisition parameters, was −1.2 ± 1.7% for the forensic and − 1.6 ± 3.5% for the clinical dataset. Among the parameters studied, time interval and body weight were identified as the main sources of error for asynchronous calibration, followed by table height and reconstruction kernel. Based on these results, a correction method was proposed to improve the calibration accuracy.


  • Open Access

    QCT-based spatio-temporal aging atlas of the proximal femur BMD and cortical geometry

    by Alice Dudle, Yvan Gugler, Osman Berk Satir, Jan Gewiess, Stefan Klein, Philippe Zysset


  • Open Access

    2D-3D reconstruction of the proximal femur from DXA scans: Evaluation of the 3D-Shaper software

    by Alice Dudle, Yvan Gugler, Michael Pretterklieber, Serge Ferrari, Kurt Lippuner, Philippe Zysset

    Introduction: Osteoporosis is currently diagnosed based on areal bone mineral density (aBMD) computed from 2D DXA scans. However, aBMD is a limited surrogate for femoral strength since it does not account for 3D bone geometry and density distribution. QCT scans combined with finite element (FE) analysis can deliver improved femoral strength predictions. However, non-negligible radiation dose and high costs prevent a systematic usage of this technique for screening purposes. As an alternative, the 3D-Shaper software (3D-Shaper Medical, Spain) reconstructs the 3D shape and density distribution of the femur from 2D DXA scans. This approach could deliver a more accurate estimation of femoral strength than aBMD by using FE analysis on the reconstructed 3D DXA.Methods: Here we present the first independent evaluation of the software, using a dataset of 77 ex vivo femora. We extend a prior evaluation by including the density distribution differences, the spatial correlation of density values and an FE analysis. Yet, cortical thickness is left out of this evaluation, since the cortex is not resolved in our FE models.Results: We found an average surface distance of 1.16 mm between 3D DXA and QCT images, which shows a good reconstruction of the bone geometry. Although BMD values obtained from 3D DXA and QCT correlated well (r2 = 0.92), the 3D DXA BMD were systematically lower. The average BMD difference amounted to 64 mg/cm3, more than one-third of the 3D DXA BMD. Furthermore, the low correlation (r2 = 0.48) between density values of both images indicates a limited reconstruction of the 3D density distribution. FE results were in good agreement between QCT and 3D DXA images, with a high coefficient of determination (r2 = 0.88). However, this correlation was not statistically different from a direct prediction by aBMD. Moreover, we found differences in the fracture patterns between the two image types. QCT-based FE analysis resulted mostly in femoral neck fractures and 3D DXA-based FE in subcapital or pertrochanteric fractures.Discussion: In conclusion, 3D-Shaper generates an altered BMD distribution compared to QCT but, after careful density calibration, shows an interesting potential for deriving a standardized femoral strength from a DXA scan.