Yizhu Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yizhu Wang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Huantong Shi
Xi’an Jiaotong University
4 shared publications - Peizhou Zhang
State Key Laboratory of Electical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, People’s Republic of China
4 shared publications - Xingwen Li
Xi’an Jiaotong University
4 shared publications Aici Qiu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University , Xi’an 710049, China
3 shared publications- Dongsheng Wang
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University , Xi'an 710049
2 shared publications - Jian Wu
Xi’an Jiaotong University
2 shared publications
Latest Publications
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (6) , 3419-3429
Modeling of X-ray Radiation of High-Voltage Vacuum Interrupters and Experimental Verification
The X-ray generated by vacuum interrupters (VIs) has received increasing attention as VIs develop towards higher voltage level. In this paper, a model is proposed to simulate the X-ray generation and transport in VIs based on measured voltage and current, which considers the electron field emission and acceleration, the bremsstrahlung, and the interaction between X-ray and material, enabling the calculation of X-ray dose and spectrum. Experimental measurements were then conducted on 126 kV and 252 kV VIs during power frequency voltage tests to verify the model, including the longitudinal and angular dose distribution, and the X-ray dose and spectrum using a custom-designed absorption spectrometer. For both VIs, the calculated X-ray spectrum shows more than 93% similarity compared to the measurement, and the calculated dose value shows about 35% negative deviation. By considering charge accumulation on the shield, which notably alertes the electron trajectories, the dose deviation was reduced to below 30%. This study aims to provide a foundation for further in-depth investigation of X-ray characteristics and effects in high-voltage vacuum interrupters.
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 39 (6) , 3419-3429
Modeling of X-ray Radiation of High-Voltage Vacuum Interrupters and Experimental Verification
The X-ray generated by vacuum interrupters (VIs) has received increasing attention as VIs develop towards higher voltage level. In this paper, a model is proposed to simulate the X-ray generation and transport in VIs based on measured voltage and current, which considers the electron field emission and acceleration, the bremsstrahlung, and the interaction between X-ray and material, enabling the calculation of X-ray dose and spectrum. Experimental measurements were then conducted on 126 kV and 252 kV VIs during power frequency voltage tests to verify the model, including the longitudinal and angular dose distribution, and the X-ray dose and spectrum using a custom-designed absorption spectrometer. For both VIs, the calculated X-ray spectrum shows more than 93% similarity compared to the measurement, and the calculated dose value shows about 35% negative deviation. By considering charge accumulation on the shield, which notably alertes the electron trajectories, the dose deviation was reduced to below 30%. This study aims to provide a foundation for further in-depth investigation of X-ray characteristics and effects in high-voltage vacuum interrupters.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Compact hard x-ray flash radiography device based on wire-shorted low-impedance rod pinch diode
A rod pinch diode (RPD) is a feasible load configuration to generate a high-brightness, small-size hard x-ray radiation source. In this paper, the radiography performance of a wire-shorted low-impedance RPD on a compactly designed table-top driver (WRPD-1) is demonstrated for the first time. The driver consists of four high-power discharge branches connected in parallel, with each branch consisting of two metal-film capacitors and one multigap field-distortion switch in series. The four branches are triggered synchronously to generate a fast-rising current pulse: the inductance of the load section at the short circuit is ∼10 nH, and the short-circuit current amplitude is ∼325 kA at ±90 kV charging voltage, with a 10%–90% rise time of 110 ns. With a low-impedance RPD shorted by an 18-µm-diameter aluminum wire, a quasi-spherical x-ray focal spot with diameter 10 keV reaches ∼1.16 J. The present results show that the device can serve well for the flash radiography diagnosis and potentially as an efficient light source for dynamic x-ray diffraction.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Compact hard x-ray flash radiography device based on wire-shorted low-impedance rod pinch diode
A rod pinch diode (RPD) is a feasible load configuration to generate a high-brightness, small-size hard x-ray radiation source. In this paper, the radiography performance of a wire-shorted low-impedance RPD on a compactly designed table-top driver (WRPD-1) is demonstrated for the first time. The driver consists of four high-power discharge branches connected in parallel, with each branch consisting of two metal-film capacitors and one multigap field-distortion switch in series. The four branches are triggered synchronously to generate a fast-rising current pulse: the inductance of the load section at the short circuit is ∼10 nH, and the short-circuit current amplitude is ∼325 kA at ±90 kV charging voltage, with a 10%–90% rise time of 110 ns. With a low-impedance RPD shorted by an 18-µm-diameter aluminum wire, a quasi-spherical x-ray focal spot with diameter 10 keV reaches ∼1.16 J. The present results show that the device can serve well for the flash radiography diagnosis and potentially as an efficient light source for dynamic x-ray diffraction.
- 22 June 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (24) , 243301
X-ray spectrum estimation of a low-impedance rod pinch diode via transmission-absorption measurement and Monte-Carlo simulation
The x-ray spectrum of a flash radiography source based on wire-shorted rod-pinch diode (RPD) is measured by an absorption spectrometer and calculated by the Geant4 Monte-Carlo code. The RPD is driven by a two-stage linear transformer driver (charging voltage ±45 kV per stage), which delivers ∼300 kA current within ∼200 ns on a short-circuit inductive load (∼30 nH). The spectrometer consists of LiF thermoluminescence dosimeters and metal filters of different materials and thicknesses, and the spectrum is reconstructed based on the Geant4 simulated dosimeter responses to various photon energies through different filters. The measured spectrum reaches an endpoint photon energy of ∼130 keV. The radiation characteristics of the RPD in the experiment are also modeled in Geant4 using measured voltage and current waveforms, and the results show an overestimation in photon number and endpoint energy (∼147 keV) compared to the measured spectrum, which indicates that during the bremsstrahlung process, the effective electron current is ∼27% of the total current, and the effective voltage is ∼12% lower than the directly reconstructed resistive voltage. A rough agreement is found between the spectra results and the non-relativistic Bethe–Heitler model with Sommerfeld correction; therefore, the analytic result can serve as an initial guess for spectrum reconstruction methods such as the perturbation method.
- 22 June 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (24) , 243301
X-ray spectrum estimation of a low-impedance rod pinch diode via transmission-absorption measurement and Monte-Carlo simulation
The x-ray spectrum of a flash radiography source based on wire-shorted rod-pinch diode (RPD) is measured by an absorption spectrometer and calculated by the Geant4 Monte-Carlo code. The RPD is driven by a two-stage linear transformer driver (charging voltage ±45 kV per stage), which delivers ∼300 kA current within ∼200 ns on a short-circuit inductive load (∼30 nH). The spectrometer consists of LiF thermoluminescence dosimeters and metal filters of different materials and thicknesses, and the spectrum is reconstructed based on the Geant4 simulated dosimeter responses to various photon energies through different filters. The measured spectrum reaches an endpoint photon energy of ∼130 keV. The radiation characteristics of the RPD in the experiment are also modeled in Geant4 using measured voltage and current waveforms, and the results show an overestimation in photon number and endpoint energy (∼147 keV) compared to the measured spectrum, which indicates that during the bremsstrahlung process, the effective electron current is ∼27% of the total current, and the effective voltage is ∼12% lower than the directly reconstructed resistive voltage. A rough agreement is found between the spectra results and the non-relativistic Bethe–Heitler model with Sommerfeld correction; therefore, the analytic result can serve as an initial guess for spectrum reconstruction methods such as the perturbation method.
- 20 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (4) , 1142-1149
Sub-Millimeter Hard X-Ray Source Based on Wire-Shorted Low-Impedance Rod Pinch Diode
Rod pinch diode (RPD) is an intense X-ray point source with a millimeter spot diameter, tens of nanosecond pulsewidth, and tens of keV to MeV photon energy, resulting in extraordinary flash radiography performance. Classical RPD is featured with a high-impedance vacuum gap between the annular cathode and the central anode rod, which limits the electron current and electrical power density, therefore is not conducive to the improvement of brightness. Plasma prefilling can effectively reduce the RPD impedance, thereby increasing the electron current and realizing an impedance match of RPD with low-impedance, high-power-density drivers. In this article, an experimental study on plasma-prefilled RPD is carried out based on a fast linear transformer driver (FLTD) with relatively low charging voltage; the RPD anode and cathode are initially connected by metal wires, which are transformed into plasma shortly after the onset of discharge current. A quasi-spherical X-ray spot is obtained with $\sim$ 0.45 mm diameter, $\sim$ 30 ns pulsewidth, 0.6 rad@1 m (LiF) dose, and 55–60 keV equivalent mono-energy photon energy. The radiography performance is further characterized by a tungsten rolled-edge and slit plate. The preliminary results proved the feasibility of low-impedance RPD as a flash radiography source within the relatively low photon energy range.
- 20 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (4) , 1142-1149
Sub-Millimeter Hard X-Ray Source Based on Wire-Shorted Low-Impedance Rod Pinch Diode
Rod pinch diode (RPD) is an intense X-ray point source with a millimeter spot diameter, tens of nanosecond pulsewidth, and tens of keV to MeV photon energy, resulting in extraordinary flash radiography performance. Classical RPD is featured with a high-impedance vacuum gap between the annular cathode and the central anode rod, which limits the electron current and electrical power density, therefore is not conducive to the improvement of brightness. Plasma prefilling can effectively reduce the RPD impedance, thereby increasing the electron current and realizing an impedance match of RPD with low-impedance, high-power-density drivers. In this article, an experimental study on plasma-prefilled RPD is carried out based on a fast linear transformer driver (FLTD) with relatively low charging voltage; the RPD anode and cathode are initially connected by metal wires, which are transformed into plasma shortly after the onset of discharge current. A quasi-spherical X-ray spot is obtained with $\sim$ 0.45 mm diameter, $\sim$ 30 ns pulsewidth, 0.6 rad@1 m (LiF) dose, and 55–60 keV equivalent mono-energy photon energy. The radiography performance is further characterized by a tungsten rolled-edge and slit plate. The preliminary results proved the feasibility of low-impedance RPD as a flash radiography source within the relatively low photon energy range.
- 1 October 2021
- Published by Elsevier in Agriculture, Ecosystems & Environment
- Vol. 320, 107584
The effects of land management patterns on soil carbon sequestration and C:N:P stoichiometry in sloping croplands in southern China
- 1 October 2021
- Published by Elsevier in Agriculture, Ecosystems & Environment
- Vol. 320, 107584
The effects of land management patterns on soil carbon sequestration and C:N:P stoichiometry in sloping croplands in southern China