Abstract
A rod pinch diode (RPD) is a feasible load configuration to generate a high-brightness, small-size hard x-ray radiation source. In this paper, the radiography performance of a wire-shorted low-impedance RPD on a compactly designed table-top driver (WRPD-1) is demonstrated for the first time. The driver consists of four high-power discharge branches connected in parallel, with each branch consisting of two metal-film capacitors and one multigap field-distortion switch in series. The four branches are triggered synchronously to generate a fast-rising current pulse: the inductance of the load section at the short circuit is ∼10 nH, and the short-circuit current amplitude is ∼325 kA at ±90 kV charging voltage, with a 10%–90% rise time of 110 ns. With a low-impedance RPD shorted by an 18-µm-diameter aluminum wire, a quasi-spherical x-ray focal spot with diameter 10 keV reaches ∼1.16 J. The present results show that the device can serve well for the flash radiography diagnosis and potentially as an efficient light source for dynamic x-ray diffraction.
Funding Information
  • National Natural Science Foundation of China (92066207, 92066107)
  • Shaanxi Provincial Science and Technology Plan Project (2022TD-59)

This publication has 22 references indexed in Scilit: