Haddad Tarik
Haddad Tarik has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- N. L. Lezhava
RUDN University
3 shared publications - Roman F. Mukhametshin
Peoples’ Friendship University of Russia named after Patrice Lumumba
3 shared publications - Nidjat A. Guseynov
Peoples’ Friendship University of Russia named after Patrice Lumumba
2 shared publications - Adam Umarov
Department of Operative Dentistry, Institute of Medicine, Peoples’ Friendship University of Russia (RUDN University), Moscow 117198, Russia
1 shared publication - Aleksander A. Muraev
Peoples’ Friendship University of Russia named after Patrice Lumumba (RUDN University)
1 shared publication - Alena Kulikova
Department of Operative Dentistry, Institute of Medicine, Peoples’ Friendship University of Russia (RUDN University), Moscow 117198, Russia
1 shared publication
Latest Publications
- 12 May 2024
- Published by Alfmed LLC in Medical alphabet
- No. 11,p. 72-76
Modern approach to the treatment of postoperative symptoms of patients undergoing oral surgery
Introduction. Removal of wisdom teeth is always accompanied by the appearance of collateral edema of varying severity, pain, neurological dysfunction and inflammatory contracture of the masticatory muscles.Purpose. To evaluate the use of local apparatus hypothermia and the method of three-dimensional facial scanning for the treatment of patients after extraction of mandibular third molars.Materials and methods. 60 patients had their wisdom teeth removed. Depending on the group, local apparatus hypothermia (LAH) (study group of 30 patients) and local ice hypothermia (LIH) (control group of 30 patients) were performed after surgery. Evaluation criterion: three-dimensional scanning of the face on days 3, 5, 7.Results. In the control group, on the 3rd day the size of the edema was 6.31 mm (SD 0.81), on the 5th day – 4.88 mm (SD 0.73), on the 7th day – 3.44 mm (SD 0.88). In the study group, on the 3rd day the size of the edema was 5.09 mm (SD 0.80), on the 5th day – 2.73 mm (SD 0.71), on the 7th day – 1.28 mm (SD 0,62). In the control group, the size of edema on the 5th day changed by 22.67% compared to the 3rd day, on the 7th day by 30.12% compared to the 5th day and by 45.94% compared to 3rd day. In the study group, the size of edema on the 5th day changed by 46.42% compared to the 3rd day, on the 7th day by 53.16% compared to the 5th day and by 75.32% compared 3rd day. Comparison of groups 3, 5 and 7 in terms of absolute values of edema size and percentage change showed a statistically significant difference (pConclusion. The use of local apparatus hypothermia in the postoperative period can reduce the severity of collateral edema in a shorter period compared to standard methods of local hypothermia.
- 12 May 2024
- Published by Alfmed LLC in Medical alphabet
- No. 11,p. 72-76
Modern approach to the treatment of postoperative symptoms of patients undergoing oral surgery
Introduction. Removal of wisdom teeth is always accompanied by the appearance of collateral edema of varying severity, pain, neurological dysfunction and inflammatory contracture of the masticatory muscles.Purpose. To evaluate the use of local apparatus hypothermia and the method of three-dimensional facial scanning for the treatment of patients after extraction of mandibular third molars.Materials and methods. 60 patients had their wisdom teeth removed. Depending on the group, local apparatus hypothermia (LAH) (study group of 30 patients) and local ice hypothermia (LIH) (control group of 30 patients) were performed after surgery. Evaluation criterion: three-dimensional scanning of the face on days 3, 5, 7.Results. In the control group, on the 3rd day the size of the edema was 6.31 mm (SD 0.81), on the 5th day – 4.88 mm (SD 0.73), on the 7th day – 3.44 mm (SD 0.88). In the study group, on the 3rd day the size of the edema was 5.09 mm (SD 0.80), on the 5th day – 2.73 mm (SD 0.71), on the 7th day – 1.28 mm (SD 0,62). In the control group, the size of edema on the 5th day changed by 22.67% compared to the 3rd day, on the 7th day by 30.12% compared to the 5th day and by 45.94% compared to 3rd day. In the study group, the size of edema on the 5th day changed by 46.42% compared to the 3rd day, on the 7th day by 53.16% compared to the 5th day and by 75.32% compared 3rd day. Comparison of groups 3, 5 and 7 in terms of absolute values of edema size and percentage change showed a statistically significant difference (pConclusion. The use of local apparatus hypothermia in the postoperative period can reduce the severity of collateral edema in a shorter period compared to standard methods of local hypothermia.
- Open Access
- 18 July 2023
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 26 (2) , 144-149
Experimental justification of the use of surgical templates
Без сомнения, применение хирургических навигационных шаблонов позволяет более точно установить дентальный имплантат. Однако вопросы точности остеотомии и непосредственной установки дентального имплантата все еще остаются открытыми в силу малого количества экспериментальных исследований. Цель — обосновать применение хирургических навигационных шаблонов при дентальной имплантации на экспериментальных моделях. Проспективно были отобраны 20 операторов с разным клиническим опытом работы и разделены на 2 группы: I группа устанавливала демоимплантаты при помощи хирургического навигационного шаблона (ХНШ), II — без него. Виртуально установленный дентальный имплантат в программном обеспечении считался контрольным образцом. Всего было установлено 20 имплантатов. В качестве имплантационной системы использовали демонстрационные дентальные имплантаты Инновационной российской имплантационной системы (ИРИС) ЛИКО-М с различными диаметром и длиной, а также навигационный и стандартный хирургические наборы ИРИС. Сканирование моделей проводили при помощи сканера Shining 3D (точность 30 мкм), шаблоны изготавливали на 3D-принтере Formlabs 2 (точность 25 мкм). Критерием оценки точности при установке демоимплантатов между группами и эталоном являлись значения ангуляции (VOA, MDA) и позиции (VOP, MDA). При статистическом анализе значений ангуляции (VOA, MDA) и позиции (VOP, MDP) на КЛКТ было выявлено, что позиции установленных демоимплантатов коррелируют с методом их установки. Для MDA и VOA различия не были статистически значимыми (p=0,880 и 0,734 соответственно), а для MDP и VOP различия были статистически значимыми (p=0,004 и 0,005 соответственно). При сравнении с эталонными различиями значений VOP в I группе и MDA во II группе статистически незначимые (p=0,296 и 0,094 соответственно), а для остальных показателей статистически значимые. Результаты статистического анализа показали, что применение ХНШ в клинической практике позволяет более точно проводить остеотомию, а также устанавливать дентальный имплантат. Однако нами показано, что в некоторых значениях разницы в установке дентального имплантата с ХНШ и без нее не достигнуто. Например, ангуляция ВО без навигации у 2 участников близка к эталону, у 6 — ниже эталонного значения, а еще у 2 — выше, чем у компьютерной модели. При использовании навигации у 2 участников показатель VOA был близок к эталону, а у остальных значения были ниже. Применение статических хирургических навигационных шаблонов в большинстве клинических случаев позволяет более точно перенести запланированную позицию виртуального дентального имплантата в полости рта пациента. The use of surgical guides undoubtedly allows more accurate placement of a dental implant. However, the issues of osteotomy accuracy and direct placement of a dental implant remain open due to the small number of experimental studies. Aim: To validate the use of surgical navigation guides in experimental dental implantation. . Twenty operators with different levels of clinical experience were selected on a prospective basis and divided into 2 groups: Group I placed demo implants with a surgical navigation template (SNT), Group II without. A virtual dental implant installed in the software was used as a control. In total, 20 implants were placed. The implant system used was the Innovative Russian Implant System (IRIS) LIKO-M demonstration dental implants of various diameters and lengths, as well as the guide and standard IRIS surgical protocol. The models were scanned with a Shining 3D scanner (30 µm accuracy), the basis of template was produced on a Formlabs 2 3D printer (25 µm accuracy). Angulation (VOA, MDA) and position (VOP, MDA) values were used to evaluate the accuracy of demo implant placement between the groups and the reference. . Statistical analysis of angulation values (VOA, MDA) and position (VOP, MDP) on the CBCT showed that the positions of...
- 18 July 2023
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 26 (2) , 144-149
Open AccessExperimental justification of the use of surgical templates
Без сомнения, применение хирургических навигационных шаблонов позволяет более точно установить дентальный имплантат. Однако вопросы точности остеотомии и непосредственной установки дентального имплантата все еще остаются открытыми в силу малого количества экспериментальных исследований. Цель — обосновать применение хирургических навигационных шаблонов при дентальной имплантации на экспериментальных моделях. Проспективно были отобраны 20 операторов с разным клиническим опытом работы и разделены на 2 группы: I группа устанавливала демоимплантаты при помощи хирургического навигационного шаблона (ХНШ), II — без него. Виртуально установленный дентальный имплантат в программном обеспечении считался контрольным образцом. Всего было установлено 20 имплантатов. В качестве имплантационной системы использовали демонстрационные дентальные имплантаты Инновационной российской имплантационной системы (ИРИС) ЛИКО-М с различными диаметром и длиной, а также навигационный и стандартный хирургические наборы ИРИС. Сканирование моделей проводили при помощи сканера Shining 3D (точность 30 мкм), шаблоны изготавливали на 3D-принтере Formlabs 2 (точность 25 мкм). Критерием оценки точности при установке демоимплантатов между группами и эталоном являлись значения ангуляции (VOA, MDA) и позиции (VOP, MDA). При статистическом анализе значений ангуляции (VOA, MDA) и позиции (VOP, MDP) на КЛКТ было выявлено, что позиции установленных демоимплантатов коррелируют с методом их установки. Для MDA и VOA различия не были статистически значимыми (p=0,880 и 0,734 соответственно), а для MDP и VOP различия были статистически значимыми (p=0,004 и 0,005 соответственно). При сравнении с эталонными различиями значений VOP в I группе и MDA во II группе статистически незначимые (p=0,296 и 0,094 соответственно), а для остальных показателей статистически значимые. Результаты статистического анализа показали, что применение ХНШ в клинической практике позволяет более точно проводить остеотомию, а также устанавливать дентальный имплантат. Однако нами показано, что в некоторых значениях разницы в установке дентального имплантата с ХНШ и без нее не достигнуто. Например, ангуляция ВО без навигации у 2 участников близка к эталону, у 6 — ниже эталонного значения, а еще у 2 — выше, чем у компьютерной модели. При использовании навигации у 2 участников показатель VOA был близок к эталону, а у остальных значения были ниже. Применение статических хирургических навигационных шаблонов в большинстве клинических случаев позволяет более точно перенести запланированную позицию виртуального дентального имплантата в полости рта пациента. The use of surgical guides undoubtedly allows more accurate placement of a dental implant. However, the issues of osteotomy accuracy and direct placement of a dental implant remain open due to the small number of experimental studies. Aim: To validate the use of surgical navigation guides in experimental dental implantation. . Twenty operators with different levels of clinical experience were selected on a prospective basis and divided into 2 groups: Group I placed demo implants with a surgical navigation template (SNT), Group II without. A virtual dental implant installed in the software was used as a control. In total, 20 implants were placed. The implant system used was the Innovative Russian Implant System (IRIS) LIKO-M demonstration dental implants of various diameters and lengths, as well as the guide and standard IRIS surgical protocol. The models were scanned with a Shining 3D scanner (30 µm accuracy), the basis of template was produced on a Formlabs 2 3D printer (25 µm accuracy). Angulation (VOA, MDA) and position (VOP, MDA) values were used to evaluate the accuracy of demo implant placement between the groups and the reference. . Statistical analysis of angulation values (VOA, MDA) and position (VOP, MDP) on the CBCT showed that the positions of...
- Open Access
- 1 March 2023
- Published by MDPI AG in Dentistry Journal
- Vol. 11 (3) , 65
Irrigation in Endodontics: Polyhexanide Is a Promising Antibacterial Polymer in Root Canal Treatment
Background:chronic apical periodontitis is a common pathology in dentistry, especially in endodontics. It is necessary to systematize data concerning commonly used irrigation solutions. The development of new protocols for endodontic treatment is a very promising direction. The use of a polyhexanide-based antiseptic can positively affect the results of endodontic treatment. Methods: the review was carried out involving the search for English language research and meta-analyses in the Google Scholar and PubMed databases. Results: the number of literary sources that were identified during the literature review is 180. After excluding publications that did not match the search criteria, the total number of articles included in the systematic review was determined to be 68. Conclusions: polyhexanide is a promising solution for infected root canal irrigation. The antibacterial activity of this substance is suitable for the elimination of pathogens responsible for the appearance of apical periodontitis.
- 1 March 2023
- Published by MDPI AG in Dentistry Journal
- Vol. 11 (3) , 65
Open AccessIrrigation in Endodontics: Polyhexanide Is a Promising Antibacterial Polymer in Root Canal Treatment
Background:chronic apical periodontitis is a common pathology in dentistry, especially in endodontics. It is necessary to systematize data concerning commonly used irrigation solutions. The development of new protocols for endodontic treatment is a very promising direction. The use of a polyhexanide-based antiseptic can positively affect the results of endodontic treatment. Methods: the review was carried out involving the search for English language research and meta-analyses in the Google Scholar and PubMed databases. Results: the number of literary sources that were identified during the literature review is 180. After excluding publications that did not match the search criteria, the total number of articles included in the systematic review was determined to be 68. Conclusions: polyhexanide is a promising solution for infected root canal irrigation. The antibacterial activity of this substance is suitable for the elimination of pathogens responsible for the appearance of apical periodontitis.
- 1 January 2023
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 26 (1) , 126-131
Development and mathematical comparative analysis of orthodontic anchor mini-plate and mini-screws
- 1 January 2023
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 26 (1) , 126-131
Development and mathematical comparative analysis of orthodontic anchor mini-plate and mini-screws