TSToshiyuki Satoh

Toshiyuki Satoh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Toshiyuki Satoh has a total of 27 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Speedup of Fuzzy-Reason-Based BMI Algorithms for Neurorehabilitation

    by Takuma Saga, Norihiko Saga, Toshiyuki Sato, Nobuyoshi Hashimoto, Susumu Okumura

  • Open Access

    Evaluation of a Passive-Assist Exoskeleton Under Different Assistive Force Profiles in Agricultural Working Postures

    by Naoki Saito, Takumi Kobayashi, Kohei Akimoto, Toshiyuki Satoh, Norihiko Saga

    To enable the practical application of passive back-support exoskeletons employing pneumatic artificial muscles (PAMs) in tasks such as agricultural work, we evaluated their assistive effectiveness in a half-squatting posture with a staggered stance. In this context, assistive force profiles were adjusted according to body posture to achieve more effective support. The targeted assistive force profile was designed to be continuously active from the standing to the half-squatting position, with minimal variation across this range. The assistive force profile was developed based on a PAM contractile force model and implemented using a cam mechanism. The effectiveness of assistance was assessed by measuring body flexion angles and erector spinae muscle activity during lifting and carrying tasks. The results showed that the assistive effect was greater on the side with the forward leg. Compared to the condition without exoskeleton assistance, the conventional pulley-based system reduced muscle activity by approximately 20% whereas the cam-based system achieved a reduction of approximately 30%.


  • Open Access

    Comparison of Position Control Performance in Double Air Chambers Pneumatic Artificial Muscle

    by Naoki Saito, Editorial Office, Toshiyuki Satoh, Norihiko Saga

    This paper proposes two position control methods for a double air chambers pneumatic artificial muscle (W-PAM) developed to improve the hysteresis characteristics of the rubber-less artificial muscle and confirms their characteristics and usefulness. The proposed control methods are the external pressure-regulated position feedback control and the internal pressure-regulated position feedback control. Of the two air chambers in the W-PAM, the air chamber regulated by the feedback control is different. The steady-state characteristic and frequency characteristics of these controls were compared, and it was experimentally confirmed that the adjusted position feedback control is superior in terms of position control performance. On the other hand, we confirmed that external pressure-regulated position feedback control can express passive stiffness, which is an important characteristic of pneumatic artificial muscles. These results indicate that the W-PAM is a useful actuator for human coexistence systems, because it can express both positional control performance and softness by using different control methods depending on the application.


  • Open Access

    Stability Analysis of Passive Monopedal Dynamic Hopping

    by Jun-Ya Nagase, Sungna Yang, Toshiyuki Satoh, Norihiko Saga

    Passive dynamic locomotion occurs through the interaction of an object’s dynamics and the ground, using no actuators, sensors, or controls. Passive dynamics is important for exploring the principles of human and animal locomotion. An important characteristic is that there might be a stable limit cycle for passive dynamic locomotion. Expression of stable limit cycles in passive bipedal walking, bipedal running, and quadrupedal running has been confirmed. However, studies conducted to date have characterized passive monopedal hopping as unstable. We investigated the dynamic stability of the passive monopedal hopping without torso pitch. Numerical simulation revealed that the passive monopedal hopping examined in this study has a stable limit cycle. Moreover, both theoretical analysis and simulation results suggest that asymptotically stable fixed points of the 1-PDH model are related closely to the leg spring damping ratio and the hopping period. Results show that the 1-PDH model has high stability with respect to steps. Additionally, findings indicate that changes in leg spring stiffness cause changes in forward velocity during stable hopping with no feedback control.

  • Open Access

    Double Air Chambers Pneumatic Artificial Muscle and Non-Hysteresis Position Control

    by Naoki Saito, Toshiyuki Satoh, Norihiko Saga

    In this paper, we propose a double air chambers artificial muscle to eliminate the hysteresis in the extension and contraction movement of pneumatic artificial muscles. In this paper, the basic structure of the double air chambers artificial muscle is a rubberless artificial muscle with a particularly large hysteresis loop. The double air chambers artificial muscle aims to eliminate hysteresis by directly pressurizing the inside and outside of the air chamber and actively deforming the air chamber. The hysteresis is reduced by the pressure outside of the air chamber (external pressure). Since the appropriate external pressure varies depending on the contraction force and amount of contraction, we proposed a method to regulate the appropriate external pressure by feedback control. The experimental results show that hysteresis was eliminated in the static characteristics. It was also found that the output gain decreased, and the phase lag increased as the target frequency increased. The output gain did not change with increasing load. The phase lag tended to improve with the PID controller compared to the PI controller. These results suggest that the combination of double air chambers artificial muscle and external pressure-regulated feedback control can achieve non-hysteresis position control, and it is useful as an actuator in mechatronic systems.


  • Open Access

    Trial of Brain–Computer Interface for Continuous Motion Using Electroencephalography and Electromyography

    by Norihiko Saga, Yukina Okawa, Takuma Saga, Toshiyuki Satoh, Naoki Saito

    Most BCI systems used in neurorehabilitation detect EEG features indicating motor intent based on machine learning, focusing on repetitive movements, such as limb flexion and extension. These machine learning methods require large datasets and are time consuming, making them unsuitable for same-day rehabilitation training following EEG measurements. Therefore, we propose a BMI system based on fuzzy inference that bypasses the need for specific EEG features, introducing an algorithm that allows patients to progress from measurement to training within a few hours. Additionally, we explored the integration of electromyography (EMG) with conventional EEG-based motor intention estimation to capture continuous movements, which is essential for advanced motor function training, such as skill improvement. In this study, we developed an algorithm that detects the initial movement via EEG and switches to EMG for subsequent movements. This approach ensures real-time responsiveness and effective handling of continuous movements. Herein, we report the results of this study.


  • Artificial bee colony algorithm-based design of discrete-time stable unknown input estimator

    by Toshiyuki Satoh, Shun Nishizawa, Jun-Ya Nagase, Naoki Saito, Norihiko Saga


  • Open Access

    Smart Pneumatic Artificial Muscle Using a Bend Sensor like a Human Muscle with a Muscle Spindle

    by Norihiko Saga, Kunio Shimada, Douhaku Inamori, Naoki Saito, Toshiyuki Satoh, Jun-Ya Nagase

    Shortage of labor and increased work of young people are causing problems in terms of care and welfare of a growing proportion of elderly people. This is a looming social problem because people of advanced ages are increasing. Necessary in the fields of care and welfare, pneumatic artificial muscles in actuators of robots are being examined. Pneumatic artificial muscles have a high output per unit of weight, and they are soft, similarly to human muscles. However, in previous research of robots using pneumatic artificial muscles, rigid sensors were often installed at joints and other locations due to the robots’ structures. Therefore, we developed a smart actuator that integrates a bending sensor that functions as a human muscle spindle; it can be externally attached to the pneumatic artificial muscle. This paper reports a smart artificial muscle actuator that can sense contraction, which can be applied to developed self-monitoring and robot posture control.


  • Effects on knee joint force from a body weight load reduction system driven by rubber-less artificial muscle

    by Naoki Saito, Toshiyuki Satoh, Norihiko Saga

    Purpose: The purpose of this study is to confirm that the body weight load reduction system which is developed by us is effective to reduce the knee joint force of the walking user. This system is driven by pneumatic artificial muscle, functions as a mobile walking assist system. Design/methodology/approach: The developed body weight load reduction system driven by rubber-less artificial muscle (RLAM) was tested experimentally. Simple force feedback control is applied to the RLAM. The system moves as synchronized with vertical movement of the walking user. The knee joint force during walking experiments conducted using this system is estimated by measurement of floor reaction force and position data of lower limb joints. Findings: The knee joint force during walking is reduced when using this system. This system contributes to smooth change of knee joint force when the lower limb contacts the floor. Practical implications: This lightweight body weight load reduction system is particularly effective for realizing easy-to-use mobile walking assist system. Originality/value: A lightweight body weight load reduction system using pneumatic artificial muscle is a novel proposal. Additionally, these new evaluation results demonstrate its effectiveness for reducing knee joint force during walking.