Naoki Saito
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Naoki Saito has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Toshiyuki Satoh
Akita Prefectural University
25 shared publications - Norihiko Saga
Kwansei Gakuin University
19 shared publications Hideharu Okano
5 shared publications- Jun-Ya Nagase
Ryukoku University
4 shared publications Seiji Chonan
4 shared publicationsKotaro Kaneko
Akita Prefectural University Department of Machine Intelligence and Systems Engineering 84-4, Aza-Ebinokuchi, Tsuchiya, Yurihonjo, Akita, Japan
3 shared publications
Latest Publications
- 2 July 2026
- Published by Springer Nature
- p. 13-28
Design of Robust Unknown Input Estimator Using Artificial Bee Colony Algorithm and a Modified Objective Function
- 2 July 2026
- Published by Springer Nature
- p. 13-28
Design of Robust Unknown Input Estimator Using Artificial Bee Colony Algorithm and a Modified Objective Function
- Open Access
Evaluation of a Passive-Assist Exoskeleton Under Different Assistive Force Profiles in Agricultural Working Postures
To enable the practical application of passive back-support exoskeletons employing pneumatic artificial muscles (PAMs) in tasks such as agricultural work, we evaluated their assistive effectiveness in a half-squatting posture with a staggered stance. In this context, assistive force profiles were adjusted according to body posture to achieve more effective support. The targeted assistive force profile was designed to be continuously active from the standing to the half-squatting position, with minimal variation across this range. The assistive force profile was developed based on a PAM contractile force model and implemented using a cam mechanism. The effectiveness of assistance was assessed by measuring body flexion angles and erector spinae muscle activity during lifting and carrying tasks. The results showed that the assistive effect was greater on the side with the forward leg. Compared to the condition without exoskeleton assistance, the conventional pulley-based system reduced muscle activity by approximately 20% whereas the cam-based system achieved a reduction of approximately 30%.
Open AccessEvaluation of a Passive-Assist Exoskeleton Under Different Assistive Force Profiles in Agricultural Working Postures
To enable the practical application of passive back-support exoskeletons employing pneumatic artificial muscles (PAMs) in tasks such as agricultural work, we evaluated their assistive effectiveness in a half-squatting posture with a staggered stance. In this context, assistive force profiles were adjusted according to body posture to achieve more effective support. The targeted assistive force profile was designed to be continuously active from the standing to the half-squatting position, with minimal variation across this range. The assistive force profile was developed based on a PAM contractile force model and implemented using a cam mechanism. The effectiveness of assistance was assessed by measuring body flexion angles and erector spinae muscle activity during lifting and carrying tasks. The results showed that the assistive effect was greater on the side with the forward leg. Compared to the condition without exoskeleton assistance, the conventional pulley-based system reduced muscle activity by approximately 20% whereas the cam-based system achieved a reduction of approximately 30%.
- Open Access
- 20 February 2025
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 37 (1) , 114-122
Comparison of Position Control Performance in Double Air Chambers Pneumatic Artificial Muscle
This paper proposes two position control methods for a double air chambers pneumatic artificial muscle (W-PAM) developed to improve the hysteresis characteristics of the rubber-less artificial muscle and confirms their characteristics and usefulness. The proposed control methods are the external pressure-regulated position feedback control and the internal pressure-regulated position feedback control. Of the two air chambers in the W-PAM, the air chamber regulated by the feedback control is different. The steady-state characteristic and frequency characteristics of these controls were compared, and it was experimentally confirmed that the adjusted position feedback control is superior in terms of position control performance. On the other hand, we confirmed that external pressure-regulated position feedback control can express passive stiffness, which is an important characteristic of pneumatic artificial muscles. These results indicate that the W-PAM is a useful actuator for human coexistence systems, because it can express both positional control performance and softness by using different control methods depending on the application.
- 20 February 2025
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 37 (1) , 114-122
Open AccessComparison of Position Control Performance in Double Air Chambers Pneumatic Artificial Muscle
This paper proposes two position control methods for a double air chambers pneumatic artificial muscle (W-PAM) developed to improve the hysteresis characteristics of the rubber-less artificial muscle and confirms their characteristics and usefulness. The proposed control methods are the external pressure-regulated position feedback control and the internal pressure-regulated position feedback control. Of the two air chambers in the W-PAM, the air chamber regulated by the feedback control is different. The steady-state characteristic and frequency characteristics of these controls were compared, and it was experimentally confirmed that the adjusted position feedback control is superior in terms of position control performance. On the other hand, we confirmed that external pressure-regulated position feedback control can express passive stiffness, which is an important characteristic of pneumatic artificial muscles. These results indicate that the W-PAM is a useful actuator for human coexistence systems, because it can express both positional control performance and softness by using different control methods depending on the application.
- Open Access
Double Air Chambers Pneumatic Artificial Muscle and Non-Hysteresis Position Control
In this paper, we propose a double air chambers artificial muscle to eliminate the hysteresis in the extension and contraction movement of pneumatic artificial muscles. In this paper, the basic structure of the double air chambers artificial muscle is a rubberless artificial muscle with a particularly large hysteresis loop. The double air chambers artificial muscle aims to eliminate hysteresis by directly pressurizing the inside and outside of the air chamber and actively deforming the air chamber. The hysteresis is reduced by the pressure outside of the air chamber (external pressure). Since the appropriate external pressure varies depending on the contraction force and amount of contraction, we proposed a method to regulate the appropriate external pressure by feedback control. The experimental results show that hysteresis was eliminated in the static characteristics. It was also found that the output gain decreased, and the phase lag increased as the target frequency increased. The output gain did not change with increasing load. The phase lag tended to improve with the PID controller compared to the PI controller. These results suggest that the combination of double air chambers artificial muscle and external pressure-regulated feedback control can achieve non-hysteresis position control, and it is useful as an actuator in mechatronic systems.
Open AccessDouble Air Chambers Pneumatic Artificial Muscle and Non-Hysteresis Position Control
In this paper, we propose a double air chambers artificial muscle to eliminate the hysteresis in the extension and contraction movement of pneumatic artificial muscles. In this paper, the basic structure of the double air chambers artificial muscle is a rubberless artificial muscle with a particularly large hysteresis loop. The double air chambers artificial muscle aims to eliminate hysteresis by directly pressurizing the inside and outside of the air chamber and actively deforming the air chamber. The hysteresis is reduced by the pressure outside of the air chamber (external pressure). Since the appropriate external pressure varies depending on the contraction force and amount of contraction, we proposed a method to regulate the appropriate external pressure by feedback control. The experimental results show that hysteresis was eliminated in the static characteristics. It was also found that the output gain decreased, and the phase lag increased as the target frequency increased. The output gain did not change with increasing load. The phase lag tended to improve with the PID controller compared to the PI controller. These results suggest that the combination of double air chambers artificial muscle and external pressure-regulated feedback control can achieve non-hysteresis position control, and it is useful as an actuator in mechatronic systems.
- Open Access
- 15 July 2024
- Published by MDPI AG in Electronics
- Vol. 13 (14) , 2770
Trial of Brain–Computer Interface for Continuous Motion Using Electroencephalography and Electromyography
Most BCI systems used in neurorehabilitation detect EEG features indicating motor intent based on machine learning, focusing on repetitive movements, such as limb flexion and extension. These machine learning methods require large datasets and are time consuming, making them unsuitable for same-day rehabilitation training following EEG measurements. Therefore, we propose a BMI system based on fuzzy inference that bypasses the need for specific EEG features, introducing an algorithm that allows patients to progress from measurement to training within a few hours. Additionally, we explored the integration of electromyography (EMG) with conventional EEG-based motor intention estimation to capture continuous movements, which is essential for advanced motor function training, such as skill improvement. In this study, we developed an algorithm that detects the initial movement via EEG and switches to EMG for subsequent movements. This approach ensures real-time responsiveness and effective handling of continuous movements. Herein, we report the results of this study.
- 15 July 2024
- Published by MDPI AG in Electronics
- Vol. 13 (14) , 2770
Open AccessTrial of Brain–Computer Interface for Continuous Motion Using Electroencephalography and Electromyography
Most BCI systems used in neurorehabilitation detect EEG features indicating motor intent based on machine learning, focusing on repetitive movements, such as limb flexion and extension. These machine learning methods require large datasets and are time consuming, making them unsuitable for same-day rehabilitation training following EEG measurements. Therefore, we propose a BMI system based on fuzzy inference that bypasses the need for specific EEG features, introducing an algorithm that allows patients to progress from measurement to training within a few hours. Additionally, we explored the integration of electromyography (EMG) with conventional EEG-based motor intention estimation to capture continuous movements, which is essential for advanced motor function training, such as skill improvement. In this study, we developed an algorithm that detects the initial movement via EEG and switches to EMG for subsequent movements. This approach ensures real-time responsiveness and effective handling of continuous movements. Herein, we report the results of this study.
- 23 March 2023
- Published by Elsevier in Information Sciences
- Vol. 634, 621-649
Artificial bee colony algorithm-based design of discrete-time stable unknown input estimator
- 23 March 2023
- Published by Elsevier in Information Sciences
- Vol. 634, 621-649
Artificial bee colony algorithm-based design of discrete-time stable unknown input estimator
- Open Access
- 1 January 2023
- Published by Japan Society of Mechanical Engineers in Transactions of the JSME (in Japanese)
- Vol. 89 (918) , 22-00251
Development and Evaluation of body weight reducing walker driven by pneumatic artificial muscle
This paper describes a body weight reducing walking support system using pneumatic artificial muscles. The user of the system walks while sitting on a saddle. The saddle supports the weight of the upper body and reduces the load on the lower limbs. The saddle moves up and down according to the user's gait by force control using pneumatic artificial muscles, and always performs a constant body weight load reducing action while walking. To confirm the effect of this body weight load reducing motion on walking, a walking support system was constructed, and floor reaction force, gait, and muscle activity were measured through experiments. As a result, it was found that the body weight load reducing motion contributed to the reduction of floor reaction force and some muscle activities. It was also found that varying the amount of the assist force did not significantly affect gait.
- 1 January 2023
- Published by Japan Society of Mechanical Engineers in Transactions of the JSME (in Japanese)
- Vol. 89 (918) , 22-00251
Open AccessDevelopment and Evaluation of body weight reducing walker driven by pneumatic artificial muscle
This paper describes a body weight reducing walking support system using pneumatic artificial muscles. The user of the system walks while sitting on a saddle. The saddle supports the weight of the upper body and reduces the load on the lower limbs. The saddle moves up and down according to the user's gait by force control using pneumatic artificial muscles, and always performs a constant body weight load reducing action while walking. To confirm the effect of this body weight load reducing motion on walking, a walking support system was constructed, and floor reaction force, gait, and muscle activity were measured through experiments. As a result, it was found that the body weight load reducing motion contributed to the reduction of floor reaction force and some muscle activities. It was also found that varying the amount of the assist force did not significantly affect gait.
- Open Access
Smart Pneumatic Artificial Muscle Using a Bend Sensor like a Human Muscle with a Muscle Spindle
Shortage of labor and increased work of young people are causing problems in terms of care and welfare of a growing proportion of elderly people. This is a looming social problem because people of advanced ages are increasing. Necessary in the fields of care and welfare, pneumatic artificial muscles in actuators of robots are being examined. Pneumatic artificial muscles have a high output per unit of weight, and they are soft, similarly to human muscles. However, in previous research of robots using pneumatic artificial muscles, rigid sensors were often installed at joints and other locations due to the robots’ structures. Therefore, we developed a smart actuator that integrates a bending sensor that functions as a human muscle spindle; it can be externally attached to the pneumatic artificial muscle. This paper reports a smart artificial muscle actuator that can sense contraction, which can be applied to developed self-monitoring and robot posture control.
Open AccessSmart Pneumatic Artificial Muscle Using a Bend Sensor like a Human Muscle with a Muscle Spindle
Shortage of labor and increased work of young people are causing problems in terms of care and welfare of a growing proportion of elderly people. This is a looming social problem because people of advanced ages are increasing. Necessary in the fields of care and welfare, pneumatic artificial muscles in actuators of robots are being examined. Pneumatic artificial muscles have a high output per unit of weight, and they are soft, similarly to human muscles. However, in previous research of robots using pneumatic artificial muscles, rigid sensors were often installed at joints and other locations due to the robots’ structures. Therefore, we developed a smart actuator that integrates a bending sensor that functions as a human muscle spindle; it can be externally attached to the pneumatic artificial muscle. This paper reports a smart artificial muscle actuator that can sense contraction, which can be applied to developed self-monitoring and robot posture control.
- 20 October 2020
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 32 (5) , 885-893
Development of Semi-Crouching Assistive Device Using Pneumatic Artificial Muscle
This paper describes a semi-crouching assistive device using pneumatic artificial muscles. The goal of this device is to reduce the load on the lower back when performing work in the semi-crouching position. The load on the lower back is reduced by decreasing the compressive pressure on the lumbar disk of the lower back. This compressive pressure increases as the contraction force of the erector spine increases. Therefore, it is important to reduce the muscle activity of the erector spine. Based on the analytical result of a worker’s position model, the proposed device adopts a scheme to push the chest of the user as an appropriate assistive method. Additionally, the analytical result shows that a reduction in weight of the device is also important for decreasing the load on the lower back. Based on these results, we prototyped a lightweight semi-crouching assistive device that can generate sufficient assistive force via a pneumatic artificial muscle, which has high power to weight ratio. This device was experimentally evaluated via electromyogram of the erector spine when the user maintains a semi-crouching position. The experimental results confirmed the usefulness of this device.
- 20 October 2020
- Published by Fuji Technology Press Ltd. in Journal of Robotics and Mechatronics
- Vol. 32 (5) , 885-893
Development of Semi-Crouching Assistive Device Using Pneumatic Artificial Muscle
This paper describes a semi-crouching assistive device using pneumatic artificial muscles. The goal of this device is to reduce the load on the lower back when performing work in the semi-crouching position. The load on the lower back is reduced by decreasing the compressive pressure on the lumbar disk of the lower back. This compressive pressure increases as the contraction force of the erector spine increases. Therefore, it is important to reduce the muscle activity of the erector spine. Based on the analytical result of a worker’s position model, the proposed device adopts a scheme to push the chest of the user as an appropriate assistive method. Additionally, the analytical result shows that a reduction in weight of the device is also important for decreasing the load on the lower back. Based on these results, we prototyped a lightweight semi-crouching assistive device that can generate sufficient assistive force via a pneumatic artificial muscle, which has high power to weight ratio. This device was experimentally evaluated via electromyogram of the erector spine when the user maintains a semi-crouching position. The experimental results confirmed the usefulness of this device.
- 26 June 2019
- Published by Emerald Publishing in Industrial Robot: the international journal of robotics research and application
- Vol. 46 (5) , 642-649
Effects on knee joint force from a body weight load reduction system driven by rubber-less artificial muscle
Purpose: The purpose of this study is to confirm that the body weight load reduction system which is developed by us is effective to reduce the knee joint force of the walking user. This system is driven by pneumatic artificial muscle, functions as a mobile walking assist system. Design/methodology/approach: The developed body weight load reduction system driven by rubber-less artificial muscle (RLAM) was tested experimentally. Simple force feedback control is applied to the RLAM. The system moves as synchronized with vertical movement of the walking user. The knee joint force during walking experiments conducted using this system is estimated by measurement of floor reaction force and position data of lower limb joints. Findings: The knee joint force during walking is reduced when using this system. This system contributes to smooth change of knee joint force when the lower limb contacts the floor. Practical implications: This lightweight body weight load reduction system is particularly effective for realizing easy-to-use mobile walking assist system. Originality/value: A lightweight body weight load reduction system using pneumatic artificial muscle is a novel proposal. Additionally, these new evaluation results demonstrate its effectiveness for reducing knee joint force during walking.
- 26 June 2019
- Published by Emerald Publishing in Industrial Robot: the international journal of robotics research and application
- Vol. 46 (5) , 642-649
Effects on knee joint force from a body weight load reduction system driven by rubber-less artificial muscle
Purpose: The purpose of this study is to confirm that the body weight load reduction system which is developed by us is effective to reduce the knee joint force of the walking user. This system is driven by pneumatic artificial muscle, functions as a mobile walking assist system. Design/methodology/approach: The developed body weight load reduction system driven by rubber-less artificial muscle (RLAM) was tested experimentally. Simple force feedback control is applied to the RLAM. The system moves as synchronized with vertical movement of the walking user. The knee joint force during walking experiments conducted using this system is estimated by measurement of floor reaction force and position data of lower limb joints. Findings: The knee joint force during walking is reduced when using this system. This system contributes to smooth change of knee joint force when the lower limb contacts the floor. Practical implications: This lightweight body weight load reduction system is particularly effective for realizing easy-to-use mobile walking assist system. Originality/value: A lightweight body weight load reduction system using pneumatic artificial muscle is a novel proposal. Additionally, these new evaluation results demonstrate its effectiveness for reducing knee joint force during walking.