Michael S. F. Hoffman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Michael S. F. Hoffman has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Andrew J. Taberner
Auckland Bioengineering Institute, University of Auckland, New Zealand
1 shared publicationAndrew Taberner
Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
1 shared publicationBryan P. Ruddy
Auckland Bioengineering Institute, University of Auckland, New Zealand
1 shared publication- Bryan Paul Ruddy
Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
1 shared publication James McKeage
Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
1 shared publicationJames W. McKeage
Auckland Bioengineering Institute, University of Auckland, New Zealand
1 shared publication
Latest Publications
- Open Access
- 17 March 2023
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 18 (5) , 1165-1171
Vacuum-Assisted Needle-Free Capillary Blood Sampling
Background: Poor glycemic management persists among people practicing insulin therapy in relation to type 1 and 2 diabetes despite a clear relationship with negative health outcomes. Skin penetration by jet injection has recently been shown as a viable method for inducing blood release from fingertips. This study examines the use of vacuum to enhance the volume of blood released and quantifies any dilution of the collected blood. Methods: A single-blind crossover study involving 15 participants, each receiving four different interventions, was conducted wherein each participant served as their own control. Each participant experienced fingertip lancing and fingertip jet injection, both with and without applied vacuum. Participants were divided into three equal groups to explore different vacuum pressures. Results: This study found that glucose concentration in blood collected under vacuum following jet injection and lancing were equivalent. We found that applying a 40 kPa vacuum following jet injection produced a 35-fold increase in the collected volume. We determined the limited extent to which the injectate dilutes blood collected following jet injection. The mean dilution of blood collected by jet injection was 5.5%. We show that jet injection is as acceptable to patients as lancing, while being equally suited for conducting glucose measurements. Conclusions: Vacuum significantly enhances the volume of capillary blood released from the fingertip without any difference in pain. The blood collected by jet injection with vacuum is equivalent to that from lancing for glucose measurement purposes.
- 17 March 2023
- Published by SAGE Publications in Journal of Diabetes Science and Technology
- Vol. 18 (5) , 1165-1171
Open AccessVacuum-Assisted Needle-Free Capillary Blood Sampling
Background: Poor glycemic management persists among people practicing insulin therapy in relation to type 1 and 2 diabetes despite a clear relationship with negative health outcomes. Skin penetration by jet injection has recently been shown as a viable method for inducing blood release from fingertips. This study examines the use of vacuum to enhance the volume of blood released and quantifies any dilution of the collected blood. Methods: A single-blind crossover study involving 15 participants, each receiving four different interventions, was conducted wherein each participant served as their own control. Each participant experienced fingertip lancing and fingertip jet injection, both with and without applied vacuum. Participants were divided into three equal groups to explore different vacuum pressures. Results: This study found that glucose concentration in blood collected under vacuum following jet injection and lancing were equivalent. We found that applying a 40 kPa vacuum following jet injection produced a 35-fold increase in the collected volume. We determined the limited extent to which the injectate dilutes blood collected following jet injection. The mean dilution of blood collected by jet injection was 5.5%. We show that jet injection is as acceptable to patients as lancing, while being equally suited for conducting glucose measurements. Conclusions: Vacuum significantly enhances the volume of capillary blood released from the fingertip without any difference in pain. The blood collected by jet injection with vacuum is equivalent to that from lancing for glucose measurement purposes.
- Open Access
- 2 January 2023
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 20 (1) , 5-16
Minimally invasive capillary blood sampling methods
Whole blood samples, including arterial, venous, and capillary blood, are regularly used for disease diagnosis and monitoring. The global Covid-19 pandemic has highlighted the need for a more resil...
- 2 January 2023
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 20 (1) , 5-16
Open AccessMinimally invasive capillary blood sampling methods
Whole blood samples, including arterial, venous, and capillary blood, are regularly used for disease diagnosis and monitoring. The global Covid-19 pandemic has highlighted the need for a more resil...