Latest Publications

  • Open Access

    Vibratory and conventional impaction of acetabular components into porcine acetabula

    by Yasaman Niki, Gerd Huber, Kambiz Behzadi, Michael Morlock

    Aims: Sufficient primary implant stability with minimal bone damage is one of the challenges for uncemented implant fixation to prevent periprosthetic fractures and implant loosening. A pilot study on a non-viscoelastic material (polyurethane foam) showed a reduced impaction force when using vibratory implant insertion. This study assessed the effectiveness of vibratory implant insertion compared to an established implant insertion method in physiological viscoelastic bone from porcine hips.Methods: Acetabular components were impacted line-to-line and into 1 mm nominal undersized cavities in porcine acetabula (n = 24 in total, n = 6 acetabula per group of study) using vibration (60 Hz) and 1 Hz (established) impaction methods. The impaction force, remaining polar gap, and lever-out moment were measured and compared between the impaction methods and different press-fits.Results: The vibratory impaction method produced almost 40% lower impaction forces at both press-fit levels. However, complete seating at the nominal press-fit of 1 mm was not achieved, and primary stability was lower for the vibratory impaction for either press-fit.Conclusion: Bone fracture risk due to high impaction forces could be reduced by vibrational implant insertion at the cost of a reduction in primary stability. The outcome of the vibratory impaction method in porcine bone was similar to a previous study using polyurethane foams, suggesting that the viscoelasticity of bone may not play a crucial role during press-fit implant impaction.Cite this article: Bone Joint Res 2025;14(4):306–314.


  • Open Access

    Vibratory insertion of press-fit acetabular components requires less force than a single blow technique

    by Yasaman Niki, Gerd Huber, Kambiz Behzadi, Michael M. Morlock

    Aims: Periprosthetic fracture and implant loosening are two of the major reasons for revision surgery of cementless implants. Optimal implant fixation with minimal bone damage is challenging in this procedure. This pilot study investigates whether vibratory implant insertion is gentler compared to consecutive single blows for acetabular component implantation in a surrogate polyurethane (PU) model.Methods: Acetabular components (cups) were implanted into 1 mm nominal under-sized cavities in PU foams (15 and 30 per cubic foot (PCF)) using a vibratory implant insertion device and an automated impaction device for single blows. The impaction force, remaining polar gap, and lever-out moment were measured and compared between the impaction methods.Results: Impaction force was reduced by 89% and 53% for vibratory insertion in 15 and 30 PCF foams, respectively. Both methods positioned the component with polar gaps under 2 mm in 15 PCF foam. However, in 30 PCF foam, the vibratory insertion resulted in a clinically undesirable polar gap of over 2 mm. A higher lever-out moment was achieved with the consecutive single blow insertion by 42% in 15 PCF and 2.7 times higher in 30 PCF foam.Conclusion: Vibratory implant insertion may lower periprosthetic fracture risk by reducing impaction forces, particularly in low-quality bone. Achieving implant seating using vibratory insertion requires adjustment of the nominal press-fit, especially in denser bone. Further preclinical testing on real bone tissue is necessary to assess whether its viscoelasticity in combination with an adjusted press-fit can compensate for the reduced primary stability after vibratory insertion observed in this study.Cite this article: Bone Joint Res 2024;13(6):272–278.


  • Impaction procedure influences primary stability of acetabular press-fit components

    by Miriam Ruhr, Gerd Huber, Yasaman Niki, Larissa Lohner, Benjamin Ondruschka, Michael M. Morlock

    Aims: The aim of the study was to investigate whether the primary stability of press-fit acetabular components can be improved by altering the impaction procedure.Methods: Three impaction procedures were used to implant acetabular components into human cadaveric acetabula using a powered impaction device. An impaction frequency of 1 Hz until complete component seating served as reference. Overimpaction was simulated by adding ten strokes after complete component seating. High-frequency implantation was performed at 6 Hz. The lever-out moment of the acetabular components was used as measure for primary stability. Permanent bone deformation was assessed by comparison of double micro-CT (µCT) measurements before and after impaction. Acetabular component deformation and impaction forces were recorded, and the extent of bone-implant contact was determined from 3D laser scans.Results: Overimpaction reduced primary acetabular component stability (p = 0.038) but did not significantly increase strain release after implantation (p = 0.117) or plastic deformations (p = 0.193). Higher press-fits were associated with larger polar gaps for the 1 Hz reference impaction (p = 0.002, R2 = 0.77), with a similar trend for overimpaction (p = 0.082, R2 = 0.31). High-frequency impaction did not significantly increase primary stability (p = 0.170) at lower impaction forces (p = 0.001); it was associated with smaller plastic deformations (p = 0.035, R2 = 0.34) and a trend for increased acetabular component relaxation between strokes (p = 0.112). Higher press-fit was not related to larger polar gaps for the 6 Hz impaction (p = 0.346).Conclusion: Overimpaction of press-fit acetabular components should be prevented since additional strokes can be associated with increased bone damage and reduced primary stability as shown in this study. High-frequency impaction at 6 Hz was shown to be beneficial compared with 1 Hz impaction. This benefit has to be confirmed in clinical studies.Cite this article: Bone Joint J 2023;105-B(3):261–268.