Jianru Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jianru Zhang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Wuwei Ren
ShanghaiTech University
5 shared publications - Jiahua Jiang
School of Mathematics, University of Birmingham, Birmingham, UK
3 shared publications - Guohua Cao
ShanghaiTech University
2 shared publications Jiahua Jiang
ShanghaiTech University
2 shared publications- Linlin Li
ShanghaiTech University
2 shared publications Tuoyu Cao
United Imaging Healthcare Co., Ltd
2 shared publications
Latest Publications
- 28 September 2025
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (2)
High‐Fidelity Solution Decomposition Fluorescence Tomography in the Presence of Background Interference
Fluorescence imaging is a cornerstone of preclinical research, yet its utility is hindered by semi‐quantitative limitations due to light scattering. Fluorescence molecular tomography (FMT) aims to overcome these constraints by generating 3D fluorophore maps through model‐based reconstruction. However, background fluorescence, resulting from non‐specific probe binding and autofluorescence, significantly compromises FMT image quality with severe artifacts. Solution decomposition FMT (SD‐FMT) is introduced, an innovative reconstruction method that employs an advanced prior model to decompose the solution into multiple stochastic components. The reformulated inverse problem is resolved using a hybrid projection method (HPM), ensuring robustness and efficiency. Validated through exhaustive phantom and in vivo proof‐of‐concept studies, SD‐FMT represents a paradigm shift in FMT reconstruction, with significant implications for expanding applications in preclinical research and advancing fluorescence‐guided surgical navigation.
- 28 September 2025
- Published by Wiley in Laser & Photonics Reviews
- Vol. 20 (2)
High‐Fidelity Solution Decomposition Fluorescence Tomography in the Presence of Background Interference
Fluorescence imaging is a cornerstone of preclinical research, yet its utility is hindered by semi‐quantitative limitations due to light scattering. Fluorescence molecular tomography (FMT) aims to overcome these constraints by generating 3D fluorophore maps through model‐based reconstruction. However, background fluorescence, resulting from non‐specific probe binding and autofluorescence, significantly compromises FMT image quality with severe artifacts. Solution decomposition FMT (SD‐FMT) is introduced, an innovative reconstruction method that employs an advanced prior model to decompose the solution into multiple stochastic components. The reformulated inverse problem is resolved using a hybrid projection method (HPM), ensuring robustness and efficiency. Validated through exhaustive phantom and in vivo proof‐of‐concept studies, SD‐FMT represents a paradigm shift in FMT reconstruction, with significant implications for expanding applications in preclinical research and advancing fluorescence‐guided surgical navigation.
- Open Access
- 29 April 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (10) , 105010
Robust residual-guided iterative reconstruction for sparse-view CT in small animal imaging
Objective . We introduce a robust image reconstruction algorithm named residual-guided Golub–Kahan iterative reconstruction technique (RGIRT) designed for sparse-view computed tomography (CT), which aims at high-fidelity image reconstruction from a limited number of projection views. Approach . RGIRT utilizes an inner-outer dual iteration framework, with a flexible least square QR (FLSQR) algorithm implemented in the inner iteration and a restarted iterative scheme applied in the outer iteration. The inner FLSQR employs a flexible Golub–Kahan bidiagonalization method to reduce the size of the inverse problem, and a weighted generalized cross-validation method to adaptively estimate the regularization hyper-parameter. The inner iteration efficiently yields the intermediate reconstruction result, while the outer iteration minimizes the residual and refines the solution by using the result obtained from the inner iteration. Main results . The reconstruction performance of RGIRT is evaluated and compared to other reference methods (FBPConvNet, SART-TV, and FLSQR) using projection data from both numerical phantoms and real experimental Micro-CT data. The experimental findings, from testing various numbers of projection views and different noise levels, underscore the robustness of RGIRT. Meanwhile, theoretical analysis confirms the convergence of residual for our approach. Significance . We propose a robust iterative reconstruction algorithm for x-ray CT scans with sparse views, thereby shortening scanning time and mitigating excessive ionizing radiation exposure to small animals.
- 29 April 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (10) , 105010
Open AccessRobust residual-guided iterative reconstruction for sparse-view CT in small animal imaging
Objective . We introduce a robust image reconstruction algorithm named residual-guided Golub–Kahan iterative reconstruction technique (RGIRT) designed for sparse-view computed tomography (CT), which aims at high-fidelity image reconstruction from a limited number of projection views. Approach . RGIRT utilizes an inner-outer dual iteration framework, with a flexible least square QR (FLSQR) algorithm implemented in the inner iteration and a restarted iterative scheme applied in the outer iteration. The inner FLSQR employs a flexible Golub–Kahan bidiagonalization method to reduce the size of the inverse problem, and a weighted generalized cross-validation method to adaptively estimate the regularization hyper-parameter. The inner iteration efficiently yields the intermediate reconstruction result, while the outer iteration minimizes the residual and refines the solution by using the result obtained from the inner iteration. Main results . The reconstruction performance of RGIRT is evaluated and compared to other reference methods (FBPConvNet, SART-TV, and FLSQR) using projection data from both numerical phantoms and real experimental Micro-CT data. The experimental findings, from testing various numbers of projection views and different noise levels, underscore the robustness of RGIRT. Meanwhile, theoretical analysis confirms the convergence of residual for our approach. Significance . We propose a robust iterative reconstruction algorithm for x-ray CT scans with sparse views, thereby shortening scanning time and mitigating excessive ionizing radiation exposure to small animals.
- 6 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (4) , 1391-1403
Multifunctional Optical Tomography System With High-Fidelity Surface Extraction Based on a Single Programmable Scanner and Unified Pinhole Modeling
Objective: Macroscopic optical tomography is a non-invasive method that can visualize the 3D distribution of intrinsic optical properties or exogenous fluorophores, making it highly attractive for small animal imaging. However, reconstructing the images requires prior knowledge of surface information. To address this, existing systems often use additional hardware components or integrate multimodal information, which is expensive and introduces new issues such as image registration. Our goal is to develop a multifunctional optical tomography system that can extract surface information using a concise hardware design. Methods: Our proposed system uses a single programmable scanner to implement both surface extraction and optical tomography functions. A unified pinhole model is used to describe both the illumination and detection procedures for capturing 3D point cloud. Line-shaped scanning is adopted to improve both spatial resolution and speed of surface extraction. Finally, we integrate the extracted surface information into the optical tomographic reconstruction to more accurately map the fluorescence distribution. Result: Comprehensive phantom experiments with different levels of complexity were designed to evaluate the performance of surface extraction and fluorescence tomography. We also imaged the axillary lymph nodes in living mice after injection of fluorophore, demonstrating the proposed system facilitates more reliable fluorescence tomography. Conclusion: We have successfully developed a versatile optical tomography system by leveraging concise hardware design and unified pinhole modeling. Phantom validation demonstrates that our system provides high-precision surface information with a maximum error of 0.1 mm, while the surface-guided FMT reconstruction is more reliable than the blind reconstruction using simplified surface geometry, elevating several quantitative metrics including RMSE, CNR, and Dice. Significance: Our work explores the feasibility of obtaining additional surface information using existing components of standalone optical tomography. This makes the optical tomographic technique more accurate and more accessible to biomedical researchers.
- 6 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (4) , 1391-1403
Multifunctional Optical Tomography System With High-Fidelity Surface Extraction Based on a Single Programmable Scanner and Unified Pinhole Modeling
Objective: Macroscopic optical tomography is a non-invasive method that can visualize the 3D distribution of intrinsic optical properties or exogenous fluorophores, making it highly attractive for small animal imaging. However, reconstructing the images requires prior knowledge of surface information. To address this, existing systems often use additional hardware components or integrate multimodal information, which is expensive and introduces new issues such as image registration. Our goal is to develop a multifunctional optical tomography system that can extract surface information using a concise hardware design. Methods: Our proposed system uses a single programmable scanner to implement both surface extraction and optical tomography functions. A unified pinhole model is used to describe both the illumination and detection procedures for capturing 3D point cloud. Line-shaped scanning is adopted to improve both spatial resolution and speed of surface extraction. Finally, we integrate the extracted surface information into the optical tomographic reconstruction to more accurately map the fluorescence distribution. Result: Comprehensive phantom experiments with different levels of complexity were designed to evaluate the performance of surface extraction and fluorescence tomography. We also imaged the axillary lymph nodes in living mice after injection of fluorophore, demonstrating the proposed system facilitates more reliable fluorescence tomography. Conclusion: We have successfully developed a versatile optical tomography system by leveraging concise hardware design and unified pinhole modeling. Phantom validation demonstrates that our system provides high-precision surface information with a maximum error of 0.1 mm, while the surface-guided FMT reconstruction is more reliable than the blind reconstruction using simplified surface geometry, elevating several quantitative metrics including RMSE, CNR, and Dice. Significance: Our work explores the feasibility of obtaining additional surface information using existing components of standalone optical tomography. This makes the optical tomographic technique more accurate and more accessible to biomedical researchers.
- Open Access
Fast, accurate and robust sparse-view CT reconstruction via residual-guided Golub-Kahan iterative reconstruction technique (RGIRT)
Reduction of projection views in X-ray computed tomography (CT) can protect patients from over exposure to ionizing radiation, thus is highly attractive for clinical applications. However, image reconstruction for sparse-view CT which aims to produce decent images from few projection views remains a challenge. To address this, we propose a Residual-guided Golub-Kahan Iterative Reconstruction Technique (RGIRT). RGIRT utilizes an inner-outer dual iteration framework, with a flexible least square QR (FLSQR) algorithm implemented in the inner iteration and a restarted iterative scheme applied in the outer iteration. The inner FLSQR employs a flexible Golub-Kahan (FGK) bidiagonalization method to reduce the dimension of the inverse problem, and a weighted generalized cross-validation (WGCV) method to adaptively estimate the regularization hyper-parameter. The inner iteration efficiently yields the intermediate reconstruction result, while the outer iteration minimizes the residual and refines the solution by using the result obtained from the inner iteration. Reconstruction performance of RGIRT is evaluated and compared to other reference methods (FBPConvNet, SART-TV, and FLSQR) using realistic mouse cardiac micro-CT data. Experiment results demonstrate RGIRT’s merits for sparse-view CT reconstruction in high accuracy, efficient computation, and stable convergence.
Open AccessFast, accurate and robust sparse-view CT reconstruction via residual-guided Golub-Kahan iterative reconstruction technique (RGIRT)
Reduction of projection views in X-ray computed tomography (CT) can protect patients from over exposure to ionizing radiation, thus is highly attractive for clinical applications. However, image reconstruction for sparse-view CT which aims to produce decent images from few projection views remains a challenge. To address this, we propose a Residual-guided Golub-Kahan Iterative Reconstruction Technique (RGIRT). RGIRT utilizes an inner-outer dual iteration framework, with a flexible least square QR (FLSQR) algorithm implemented in the inner iteration and a restarted iterative scheme applied in the outer iteration. The inner FLSQR employs a flexible Golub-Kahan (FGK) bidiagonalization method to reduce the dimension of the inverse problem, and a weighted generalized cross-validation (WGCV) method to adaptively estimate the regularization hyper-parameter. The inner iteration efficiently yields the intermediate reconstruction result, while the outer iteration minimizes the residual and refines the solution by using the result obtained from the inner iteration. Reconstruction performance of RGIRT is evaluated and compared to other reference methods (FBPConvNet, SART-TV, and FLSQR) using realistic mouse cardiac micro-CT data. Experiment results demonstrate RGIRT’s merits for sparse-view CT reconstruction in high accuracy, efficient computation, and stable convergence.