Linlin Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Linlin Li has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Wuwei Ren
ShanghaiTech University
4 shared publications Jiahua Jiang
ShanghaiTech University
2 shared publications- Jiahua Jiang
School of Mathematics, University of Birmingham, Birmingham, UK
2 shared publications - Jianru Zhang
University of Birmingham
2 shared publications Liangtao Gu
School of Information Science and Technology, ShanghaiTech University, Shanghai, China
2 shared publications- Shengyu Gao
School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore
2 shared publications
Latest Publications
- 10 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 11 (25730436) , 955-966
High Resolution Diffuse Optical Tomography via Neural Fields
Light scattering imposes a major obstacle for imaging objects seated deeply in turbid media, such as biological tissues and foggy air. Diffuse optical tomography (DOT) tackles scattering by volumetrically recovering the optical absorbance and has shown significance in medical imaging, remote sensing and autonomous driving. A conventional DOT reconstruction paradigm necessitates discretizing the object volume into voxels at a pre-determined resolution for modelling diffuse light propagation and the resultant spatial resolution of the reconstruction is generally limited. We propose NeuDOT, a novel DOT scheme based on neural fields (NF) to continuously encode the optical absorbance within the volume and subsequently bridge the gap between model efficiency and high resolution. Comprehensive experiments demonstrate that NeuDOT affords to resolve complex 3D objects at 14 mm depth with submillimeter lateral resolution, outperforming the state-of-the-art methods. NeuDOT is a high-resolution and computationally efficient tomographic method, and also unlocks further applications of NF involving light scattering.
- 10 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computational Imaging
- Vol. 11 (25730436) , 955-966
High Resolution Diffuse Optical Tomography via Neural Fields
Light scattering imposes a major obstacle for imaging objects seated deeply in turbid media, such as biological tissues and foggy air. Diffuse optical tomography (DOT) tackles scattering by volumetrically recovering the optical absorbance and has shown significance in medical imaging, remote sensing and autonomous driving. A conventional DOT reconstruction paradigm necessitates discretizing the object volume into voxels at a pre-determined resolution for modelling diffuse light propagation and the resultant spatial resolution of the reconstruction is generally limited. We propose NeuDOT, a novel DOT scheme based on neural fields (NF) to continuously encode the optical absorbance within the volume and subsequently bridge the gap between model efficiency and high resolution. Comprehensive experiments demonstrate that NeuDOT affords to resolve complex 3D objects at 14 mm depth with submillimeter lateral resolution, outperforming the state-of-the-art methods. NeuDOT is a high-resolution and computationally efficient tomographic method, and also unlocks further applications of NF involving light scattering.
- 15 April 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (9) , 15760-15773
Simultaneous reconstruction of 3D fluorescence distribution and object surface using structured light illumination and dual-camera detection
Fluorescence molecular tomography (FMT) serves as a noninvasive modality for visualizing volumetric fluorescence distribution within biological tissues, thereby proving to be an invaluable imaging tool for preclinical animal studies. The conventional FMT relies upon a point-by-point raster scan strategy, enhancing the dataset for subsequent reconstruction but concurrently elongating the data acquisition process. The resultant diminished temporal resolution has persistently posed a bottleneck, constraining its utility in dynamic imaging studies. We introduce a novel system capable of simultaneous FMT and surface extraction, which is attributed to the implementation of a rapid line scanning approach and dual-camera detection. The system performance was characterized through phantom experiments, while the influence of scanning line density on reconstruction outcomes has been systematically investigated via both simulation and experiments. In a proof-of-concept study, our approach successfully captures a moving fluorescence bolus in three dimensions with an elevated frame rate of approximately 2.5 seconds per frame, employing an optimized scan interval of 5 mm. The notable enhancement in the spatio-temporal resolution of FMT holds the potential to broaden its applications in dynamic imaging tasks, such as surgical navigation.
- 15 April 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (9) , 15760-15773
Simultaneous reconstruction of 3D fluorescence distribution and object surface using structured light illumination and dual-camera detection
Fluorescence molecular tomography (FMT) serves as a noninvasive modality for visualizing volumetric fluorescence distribution within biological tissues, thereby proving to be an invaluable imaging tool for preclinical animal studies. The conventional FMT relies upon a point-by-point raster scan strategy, enhancing the dataset for subsequent reconstruction but concurrently elongating the data acquisition process. The resultant diminished temporal resolution has persistently posed a bottleneck, constraining its utility in dynamic imaging studies. We introduce a novel system capable of simultaneous FMT and surface extraction, which is attributed to the implementation of a rapid line scanning approach and dual-camera detection. The system performance was characterized through phantom experiments, while the influence of scanning line density on reconstruction outcomes has been systematically investigated via both simulation and experiments. In a proof-of-concept study, our approach successfully captures a moving fluorescence bolus in three dimensions with an elevated frame rate of approximately 2.5 seconds per frame, employing an optimized scan interval of 5 mm. The notable enhancement in the spatio-temporal resolution of FMT holds the potential to broaden its applications in dynamic imaging tasks, such as surgical navigation.
- 6 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (4) , 1391-1403
Multifunctional Optical Tomography System With High-Fidelity Surface Extraction Based on a Single Programmable Scanner and Unified Pinhole Modeling
Objective: Macroscopic optical tomography is a non-invasive method that can visualize the 3D distribution of intrinsic optical properties or exogenous fluorophores, making it highly attractive for small animal imaging. However, reconstructing the images requires prior knowledge of surface information. To address this, existing systems often use additional hardware components or integrate multimodal information, which is expensive and introduces new issues such as image registration. Our goal is to develop a multifunctional optical tomography system that can extract surface information using a concise hardware design. Methods: Our proposed system uses a single programmable scanner to implement both surface extraction and optical tomography functions. A unified pinhole model is used to describe both the illumination and detection procedures for capturing 3D point cloud. Line-shaped scanning is adopted to improve both spatial resolution and speed of surface extraction. Finally, we integrate the extracted surface information into the optical tomographic reconstruction to more accurately map the fluorescence distribution. Result: Comprehensive phantom experiments with different levels of complexity were designed to evaluate the performance of surface extraction and fluorescence tomography. We also imaged the axillary lymph nodes in living mice after injection of fluorophore, demonstrating the proposed system facilitates more reliable fluorescence tomography. Conclusion: We have successfully developed a versatile optical tomography system by leveraging concise hardware design and unified pinhole modeling. Phantom validation demonstrates that our system provides high-precision surface information with a maximum error of 0.1 mm, while the surface-guided FMT reconstruction is more reliable than the blind reconstruction using simplified surface geometry, elevating several quantitative metrics including RMSE, CNR, and Dice. Significance: Our work explores the feasibility of obtaining additional surface information using existing components of standalone optical tomography. This makes the optical tomographic technique more accurate and more accessible to biomedical researchers.
- 6 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (4) , 1391-1403
Multifunctional Optical Tomography System With High-Fidelity Surface Extraction Based on a Single Programmable Scanner and Unified Pinhole Modeling
Objective: Macroscopic optical tomography is a non-invasive method that can visualize the 3D distribution of intrinsic optical properties or exogenous fluorophores, making it highly attractive for small animal imaging. However, reconstructing the images requires prior knowledge of surface information. To address this, existing systems often use additional hardware components or integrate multimodal information, which is expensive and introduces new issues such as image registration. Our goal is to develop a multifunctional optical tomography system that can extract surface information using a concise hardware design. Methods: Our proposed system uses a single programmable scanner to implement both surface extraction and optical tomography functions. A unified pinhole model is used to describe both the illumination and detection procedures for capturing 3D point cloud. Line-shaped scanning is adopted to improve both spatial resolution and speed of surface extraction. Finally, we integrate the extracted surface information into the optical tomographic reconstruction to more accurately map the fluorescence distribution. Result: Comprehensive phantom experiments with different levels of complexity were designed to evaluate the performance of surface extraction and fluorescence tomography. We also imaged the axillary lymph nodes in living mice after injection of fluorophore, demonstrating the proposed system facilitates more reliable fluorescence tomography. Conclusion: We have successfully developed a versatile optical tomography system by leveraging concise hardware design and unified pinhole modeling. Phantom validation demonstrates that our system provides high-precision surface information with a maximum error of 0.1 mm, while the surface-guided FMT reconstruction is more reliable than the blind reconstruction using simplified surface geometry, elevating several quantitative metrics including RMSE, CNR, and Dice. Significance: Our work explores the feasibility of obtaining additional surface information using existing components of standalone optical tomography. This makes the optical tomographic technique more accurate and more accessible to biomedical researchers.