PIPiyush

Piyush

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Piyush has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Development and study of ultrasonic pulse velocity measurement system using wave analysis and two-point detection approach

    by Piyush, Sanjay Yadav, P.K. Dubey

    This article focuses on the development and analysis of an Ultrasonic Pulse Velocity (UPV) measurement system used for the evaluation of concrete and Reinforced Cement Concrete (RCC) in civil construction. The UPV tester is essential for on-site assessments of structures, as it is used to measure the velocity of ultrasonic waves within the material, directly correlating with its strength. UPV testing is affected by the attenuation of ultrasonic waves in concrete, particularly due to the interfacial transition zone. Excess ultrasonic attenuation results in the reduction in the received signal amplitude which may also results in the omission of the initial pulses due to threshold comparison at the receiver. The study highlights the impact of receiver gain on threshold error and discusses the limitations associated with ADC sampling rate and amplitude resolution. UPV measurement, including counter or data acquisition approach, have error contributions associated with threshold voltage comparison. The error due to threshold amplitude selection is quantified, emphasizing the importance of accurate signal analysis, particularly in highly attenuating medium. The article presents the design and development of a PC-based UPV tester with automatic threshold error compensation. The system includes a transmitter, receiver, 32-bit microcontroller, and a Graphical User Interface (GUI) for data analysis. The article introduces a two-point linear detection logic to minimize errors caused by selected signal amplitude and omission of initial pulses in transit time measurements. The proposed method provides effective resolution of 10 ns through software, even at low sampling rate of 2 MS/s. The experimental results demonstrate the effectiveness of the developed UPV tester, with comparisons to a reference calibration facility at CSIR-NPL. The standard deviation in the ultrasonic transit time measurement by the developed UPV device, with threshold error correction, was ±70 ns.


  • Open Access

    Development of sweep frequency ultrasonic interferometer for high precision velocity measurement in liquids

    by Nitin Dhiman, Sahil Sharma, Piyush, Bishan Kumar, Sanjay Yadav, P. K. Dubey

    An ultrasonic interferometer with variable separation between the transducer and reflector is widely used for the measurement of ultrasonic propagation velocity in liquids. The inherent limitation of such an interferometer is due to the mechanical movement of its reflector for ultrasonic wavelength measurement in a liquid medium. It is observed that the ultrasonic velocity measurement precision is adversely affected at higher frequencies compared to lower ones. For instance, in our experimentation, a standard deviation of ±21.5 m/s (±1.43%) was obtained for velocity measurement at 1.84 MHz with the consideration of two consecutive maxima, which increases drastically to ±76.8 m/s (±5.12%) at 9.4 MHz. These measurements can significantly be improved by considering many maxima and averaging for wavelength estimation. However, it still requires design attention and improvement, particularly for higher frequencies. In this article, a sweep-frequency based ultrasonic interferometer design with a fixed separation for liquid characterization is proposed and described. This technique overcomes the limitations of mechanical movement systems and also provides a better and uniform precision for lower as well as higher frequencies. The functionality of the developed sweep frequency method was tested in water, carbon tetrachloride, ethylene glycol, and glycerol, which shows good agreement with literature values. The velocity measurement in double distilled water by the developed technique at 1 Hz sweep resolution has shown an improved standard deviation of ±0.74 m/s (±0.05%) at 9.4 MHz.


  • Measurement of ultrasonic pulse velocity with improved accuracy using automatic threshold error correction

    by Piyush, Nitin Dhiman, Bishan Kumar, Sanjay Yadav, P. K. Dubey

    Ultrasonic Pulse Velocity (UPV) measurement is extensively used to monitor the strength and health of concrete structures as per American Society for Testing and Materials C 597 – 09. The commercially available UPV measurement systems work on the basis of single threshold detection of the received signal. Therefore, measurement accuracy is affected due to threshold error. The effect is sensitive to the signal amplitude reaching the threshold comparator and, hence, receiver gain. It is observed that a UPV tester operating at 50 kHz to test concrete might generate an error of up to 10% in the ultrasonic transit time measurement of 50 µs. Hence, it is of great concern and needs to be improved. In this article, the UPV measurement circuit capable of detecting and compensating the threshold error is described. The threshold error correction is achieved with the help of two threshold comparators and two hybrid counters. The circuit developed minimizes the threshold error for wide receiver gain. The measurement carried out with the developed system shows significant improvement, having deviations within 100 ns.