SSScott Arockia Singh

Scott Arockia Singh

*This is an algorithmically generated author record based on publicly available information.

Scott Arockia Singh has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Single-Shot 3D Incoherent Imaging Using Deterministic and Random Optical Fields with Lucy–Richardson–Rosen Algorithm

    by Agnes Pristy Ignatius Xavier, Francis Gracy Arockiaraj, Shivasubramanian Gopinath, Aravind Simon John Francis Rajeswary, Andra Naresh Kumar Reddy, Rashid A. Ganeev, M. Scott Arockia Singh, S. D. Milling Tania, Vijayakumar Anand

    Coded aperture 3D imaging techniques have been rapidly evolving in recent years. The two main directions of evolution are in aperture engineering to generate the optimal optical field and in the development of a computational reconstruction method to reconstruct the object’s image from the intensity distribution with minimal noise. The goal is to find the ideal aperture–reconstruction method pair, and if not that, to optimize one to match the other for designing an imaging system with the required 3D imaging characteristics. The Lucy–Richardson–Rosen algorithm (LR2A), a recently developed computational reconstruction method, was found to perform better than its predecessors, such as matched filter, inverse filter, phase-only filter, Lucy–Richardson algorithm, and non-linear reconstruction (NLR), for certain apertures when the point spread function (PSF) is a real and symmetric function. For other cases of PSF, NLR performed better than the rest of the methods. In this tutorial, LR2A has been presented as a generalized approach for any optical field when the PSF is known along with MATLAB codes for reconstruction. The common problems and pitfalls in using LR2A have been discussed. Simulation and experimental studies for common optical fields such as spherical, Bessel, vortex beams, and exotic optical fields such as Airy, scattered, and self-rotating beams have been presented. From this study, it can be seen that it is possible to transfer the 3D imaging characteristics from non-imaging-type exotic fields to indirect imaging systems faithfully using LR2A. The application of LR2A to medical images such as colonoscopy images and cone beam computed tomography images with synthetic PSF has been demonstrated. We believe that the tutorial will provide a deeper understanding of computational reconstruction using LR2A.


  • Open Access

    Outcome of Chivates trans anal suture mucoanopexy procedure for haemorrhoids: primary findings in South Indian population

    by Scott Arokia Singh M.

    Background: This procedure is used by surgeons all across India and we offer our preliminary findings from Southern India. To the best of our knowledge, this is the first publication from the rural part of Tamil Nadu to be disclosed. Methods: One of the novel methods for treating grade III and IV haemorrhoids is the Chivate's procedure (CP). Restoring lowered anal cushions to their original positions and ligation of blood flow to the anal canal are the two main components of the Chivates surgery. Hemorrhoids' engorgement, prolapse, recurrence, and discomfort are the main factors influencing how haemorrhoids are treated. Results: This procedure is the effective method with successful outcome in grade III and grade IV haemorrhoids. No complications like pain, soiling and leakage were noted. Conclusions: CP of trans anal suture rectopexy for haemorrhoid is a very promising procedure with a short learning curve. In our experience with 58 patients, we conclude that the procedure successfully controlled mass, prolapse and recurrence of haemorrhoids.  


  • Open Access

    Single Shot 3D Incoherent Imaging Using Deterministic and Random Optical Fields with Lucy-Richardson-Rosen Algorithm

    by Agnes Pristy Ignatius Xavier, Francis Gracy Arockiaraj, Shivasubramanian Gopinath, Aravind Simon John Francis Rajeswary, Andra Naresh Kumar Reddy, Rashid A. Ganeev, Scott Arockia Singh M, Milling Tania S. D, Vijayakumar Anand

    Coded aperture 3D imaging techniques have been rapidly evolving in the recent years. The two main directions of evolution are in aperture engineering to generate the optimal optical field and in development of computational reconstruction to reconstruct the object’s image from the intensity distribution with a minimal noise. The goal is to find the ideal aperture-reconstruction method pair and if not, to optimize one to match the other for designing an imaging system with required 3D imaging characteristics. Lucy-Richardson-Rosen algorithm (LR2A), a recently developed computational reconstruction method was found to perform better than its predecessors such as matched filter, Weiner filter, phase-only filter, Lucy-Richardson algorithm and non-linear reconstruction (NLR) for certain apertures when the point spread function (PSF) is a real and symmetric function. For other cases of PSF, NLR performed better than the rest of the methods. In this tutorial, LR2A has been presented as a generalized approach for any optical field along with MATLAB codes for reconstruction of any image when the PSF is known. The common problems and pitfalls in using LR2A has been discussed. Simulation and experimental studies for common optical fields such as spherical, Bessel, vortex beams and exotic optical fields such as Airy, scattered and self-rotating beams have been presented. From this study, it can be seen that it is possible to transfer the 3D imaging characteristics from non-imaging type exotic fields to indirect imaging systems faithfully using LR2A. The application of LR2A to medical images such as colonoscopy images and cone beam computed tomography images with synthetic PSF has been demonstrated. We believe that the tutorial will provide a deeper understanding of computational reconstruction using LR2A.


  • Open Access

    Outcome of Laparostomy as a Treatment Measure for Abdominal Compartment Syndrome: A Retrospective Study

    by Eva Sherin Saravana Kumar, Scott Arockia Singh, Bala Vidhya Sagar, Nithila Chithambaram, Sabu Jeyasekharan, Devaprasath Jeyasekharan

    Objectives: Abdominal compartment syndrome is a life-threatening condition that affects critically ill patients. When pressures inside a fixed cavity of the body increases, ischemia, muscle injury, and organ failure can result. To assess the benefits and outcomes of laparostomy for abdominal compartment syndrome. Material and Methods: This retrospective study included patients who underwent a laparostomy procedure as a treatment measure for abdominal compartment syndrome, secondary to different etiologies such as sepsis and major abdominal visceral trauma. Results: Although there are a few complications such as incisional hernia in the future following a laparostomy, the mortality rate following the procedure is less than < 10%, thus ensuring a good prognosis for patients who present with acute surgical emergencies. It could also be further noted that an early closure by 7 to 14 days had definite beneficial outcomes as compared with delayed closure of more than 14 days. It prevented most long-term complications such as entero-atmospheric fistula formation or granuloma formation, the outcomes of which were further aided by the use of a transparent custom-made polypropylene mesh. Conclusion: Laparostomy is the gold standard treatment for abdominal compartment syndrome. The use of a custom-made polypropylene mesh has proven to have the least complications in the follow-up period. Incisional hernias are the most common complications documented, followed by entero-atmospheric fistula.