Hongchao Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hongchao Zhao has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
Lei Fan
4 shared publicationsMing Li
4 shared publications- Xida Han
MOE Key Laboratory of TianQin Mission, TianQin Research Center for Gravitational Physics & School of Physics and Astronomy, Frontiers Science Center for TianQin, Gravitational Wave Research Center of CNSA, Sun Yat-sen University (Zhuhai Campus), Zhuhai 519082, People’s Republic of China
4 shared publications Xiaolei Jiao
3 shared publications- Yong Yan
Sun Yat-Sen University (Zhuhai Campus)
3 shared publications - Yuwei Wu
School of Advanced Manufacturing, Sun Yat-Sen University, Shenzhen, People’s Republic of China
3 shared publications
Latest Publications
- 24 November 2026
- Published by Elsevier in International Journal of Mechanical Sciences
Generative Inverse Design of Quasi-Zero-Stiffness Cells for Prescribed Loads
- 24 November 2026
- Published by Elsevier in International Journal of Mechanical Sciences
Generative Inverse Design of Quasi-Zero-Stiffness Cells for Prescribed Loads
- Open Access
- 3 July 2026
- Published by Elsevier in SSRN Electronic Journal
Enhancing the Load-Bearing Capacity of Revolved Quasi-Zero Stiffness Cells Using Generative Adversarial Networks
Low-frequency broadband vibration isolation is critical for precision manufacturing and aerospace applications, yet traditional linear isolators suffer from the fundamental trade-off between high load capacity and low stiffness. Rotational quasi-zero stiffness (QZS) cells using Non-Uniform Rational B-Splines (NURBS) offer a promising high-static-low-dynamic-stiffness (HSLDS) solution. However, NURBS’ high-dimensional parameter space renders conventional forward design inefficient and prone to local optima, while existing inverse methods are limited to narrow load ranges and lack generalization capability. This paper presents an end-to-end Generative Adversarial Network (GAN)-based inverse design framework for QZS cells, directly generating geometry configurations from target loads (50–140 N). Validation on eight designed cells shows a maximum load-bearing ratio of 218, ultra-broadband isolation from 5 Hz to 300 Hz, and a minimum transmissibility of -49.68 dB. A Young’s modulus-normalized dimensionless load indicator Ψ is introduced, enabling evaluation of the cross-material transferability of WGAN-generated geometries across photocurable resins, mitigating the limitation of single-material evaluation in prior studies. This framework establishes a scalable paradigm for rapid, material-adaptive customized design of high-performance 3D-printed QZS vibration isolators.
- 3 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEnhancing the Load-Bearing Capacity of Revolved Quasi-Zero Stiffness Cells Using Generative Adversarial Networks
Low-frequency broadband vibration isolation is critical for precision manufacturing and aerospace applications, yet traditional linear isolators suffer from the fundamental trade-off between high load capacity and low stiffness. Rotational quasi-zero stiffness (QZS) cells using Non-Uniform Rational B-Splines (NURBS) offer a promising high-static-low-dynamic-stiffness (HSLDS) solution. However, NURBS’ high-dimensional parameter space renders conventional forward design inefficient and prone to local optima, while existing inverse methods are limited to narrow load ranges and lack generalization capability. This paper presents an end-to-end Generative Adversarial Network (GAN)-based inverse design framework for QZS cells, directly generating geometry configurations from target loads (50–140 N). Validation on eight designed cells shows a maximum load-bearing ratio of 218, ultra-broadband isolation from 5 Hz to 300 Hz, and a minimum transmissibility of -49.68 dB. A Young’s modulus-normalized dimensionless load indicator Ψ is introduced, enabling evaluation of the cross-material transferability of WGAN-generated geometries across photocurable resins, mitigating the limitation of single-material evaluation in prior studies. This framework establishes a scalable paradigm for rapid, material-adaptive customized design of high-performance 3D-printed QZS vibration isolators.
- Open Access
Center of Mass Measurement Technology and Its Research Progress in the Aerospace Field
The center of mass is a key parameter characterizing the mass distribution of an object, and its measurement holds significant importance in high-tech fields such as aerospace, the defense industry, and precision manufacturing. With modern engineering demanding ever-increasing spacecraft flight stability, control precision, and precision measurement requirements, the accuracy, efficiency, and adaptability of center of mass measurement have also become research hotspots. This paper systematically reviews current mainstream measurement techniques, including static and dynamic methods, while analyzing their respective advantages and sources of error. By comparing Chinese and non-Chinese achievements in center of mass measurement equipment development and engineering applications, it identifies existing challenges and issues in the field and outlines future trends in center of mass measurement technology.
Open AccessCenter of Mass Measurement Technology and Its Research Progress in the Aerospace Field
The center of mass is a key parameter characterizing the mass distribution of an object, and its measurement holds significant importance in high-tech fields such as aerospace, the defense industry, and precision manufacturing. With modern engineering demanding ever-increasing spacecraft flight stability, control precision, and precision measurement requirements, the accuracy, efficiency, and adaptability of center of mass measurement have also become research hotspots. This paper systematically reviews current mainstream measurement techniques, including static and dynamic methods, while analyzing their respective advantages and sources of error. By comparing Chinese and non-Chinese achievements in center of mass measurement equipment development and engineering applications, it identifies existing challenges and issues in the field and outlines future trends in center of mass measurement technology.
- 30 December 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (2) , 025106
Flexure hinge design and optimization of a high-precision force sensor for the test mass grabbing position and release mechanism
Space-based gravitational wave detection is expected to open an observation window for gravitational wave sources in the low-frequency band. The inertial sensor is one of the key components of such detectors. To ensure that the test mass can accurately follow a geodesic trajectory, it must be precisely released within the confined vacuum chamber of the detector. This imposes specific requirements on the high integration and accuracy of contact force measurement during the grabbing and release process. This paper proposes a force sensor design employing double circular notch flexure hinges. A comparative study of single and double circular notch flexure hinge configurations reveals significant differences in terms of the distribution of maximum strain areas and the magnitude of the area-averaged strain. The double circular notch design can produce an increase in area-averaged strain of up to 351%. This study establishes a design methodology that defines a feasible range of flexure hinge parameters and their associated bonding areas. The analysis reveals that an optimal strain gauge spacing of 4–7 mm or 9-12 mm is essential for preventing bonding overlap within confined spaces. Furthermore, a force sensor calibration device was developed. Experimental characterization demonstrated that the sensor provides a full scale of 10 N, an accuracy of 0.02 N (±0.2% F.S.), a rapid response time of 12 ms, low hysteresis (0.15% F.S.) and fine repeatability (±0.2% F.S.). This study not only provides a design scheme for flexure hinge of force sensors within confined space for space-based gravitational wave detection but also presents a framework for the design of micro force sensors that satisfy the stringent requirements of aerospace and extreme industrial applications.
- 30 December 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (2) , 025106
Flexure hinge design and optimization of a high-precision force sensor for the test mass grabbing position and release mechanism
Space-based gravitational wave detection is expected to open an observation window for gravitational wave sources in the low-frequency band. The inertial sensor is one of the key components of such detectors. To ensure that the test mass can accurately follow a geodesic trajectory, it must be precisely released within the confined vacuum chamber of the detector. This imposes specific requirements on the high integration and accuracy of contact force measurement during the grabbing and release process. This paper proposes a force sensor design employing double circular notch flexure hinges. A comparative study of single and double circular notch flexure hinge configurations reveals significant differences in terms of the distribution of maximum strain areas and the magnitude of the area-averaged strain. The double circular notch design can produce an increase in area-averaged strain of up to 351%. This study establishes a design methodology that defines a feasible range of flexure hinge parameters and their associated bonding areas. The analysis reveals that an optimal strain gauge spacing of 4–7 mm or 9-12 mm is essential for preventing bonding overlap within confined spaces. Furthermore, a force sensor calibration device was developed. Experimental characterization demonstrated that the sensor provides a full scale of 10 N, an accuracy of 0.02 N (±0.2% F.S.), a rapid response time of 12 ms, low hysteresis (0.15% F.S.) and fine repeatability (±0.2% F.S.). This study not only provides a design scheme for flexure hinge of force sensors within confined space for space-based gravitational wave detection but also presents a framework for the design of micro force sensors that satisfy the stringent requirements of aerospace and extreme industrial applications.
- 8 December 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (25) , 52829-52838
Range walk error compensation for SLR using fiber-coupled SNSPDs based on differential attenuation method
In satellite laser ranging (SLR) applications, the array superconducting nanowire single photon detectors (SNSPDs) introduce the range walk error due to the response characteristics, which affects the ranging accuracy. To reduce the impact of range walk errors, what we believe to be a novel experimental approach, termed the differential attenuation walk compensation (DAWC) method, is proposed based on a comprehensive theoretical analysis of the influencing factors. By establishing a detection probability model that incorporates factors such as echo pulse energy, time jitter, and pulse width, this study systematically examines the contributions of various factors to range walk errors. Theoretical analysis indicates that attenuating the echo signal to the single-photon level and leveraging the differential delay between the reference arm and the measurement arm can effectively compensate the range walk error. To validate this approach, experimental studies are conducted, incorporating a corner reflector positioned behind the secondary mirror and a fiber optic attenuator placed before the SNSPDs. The experimental results demonstrate that the strategy enhances the ranging accuracy by 0.14 ns in terms of RMS. This corresponds to an effective compensation of at least 40%. This method provides a promising solution for improving the precision of SLR.
- 8 December 2025
- Published by Optica Publishing Group in Optics Express
- Vol. 33 (25) , 52829-52838
Range walk error compensation for SLR using fiber-coupled SNSPDs based on differential attenuation method
In satellite laser ranging (SLR) applications, the array superconducting nanowire single photon detectors (SNSPDs) introduce the range walk error due to the response characteristics, which affects the ranging accuracy. To reduce the impact of range walk errors, what we believe to be a novel experimental approach, termed the differential attenuation walk compensation (DAWC) method, is proposed based on a comprehensive theoretical analysis of the influencing factors. By establishing a detection probability model that incorporates factors such as echo pulse energy, time jitter, and pulse width, this study systematically examines the contributions of various factors to range walk errors. Theoretical analysis indicates that attenuating the echo signal to the single-photon level and leveraging the differential delay between the reference arm and the measurement arm can effectively compensate the range walk error. To validate this approach, experimental studies are conducted, incorporating a corner reflector positioned behind the secondary mirror and a fiber optic attenuator placed before the SNSPDs. The experimental results demonstrate that the strategy enhances the ranging accuracy by 0.14 ns in terms of RMS. This corresponds to an effective compensation of at least 40%. This method provides a promising solution for improving the precision of SLR.
- Top Cited Papers
- 3 April 2025
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 293
High Load-Bearing Quasi-Zero Stiffness Metamaterials for Vibration Isolation
- 3 April 2025
- Published by Elsevier in International Journal of Mechanical Sciences
- Vol. 293
Top Cited PapersHigh Load-Bearing Quasi-Zero Stiffness Metamaterials for Vibration Isolation
- 21 February 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (7) , 1639-1645
Performance comparison of two telescope configurations for backscattered light in space gravitational wave detection
In space-based gravitational wave detection telescopes, backscattered light generated by the optical elements of the telescope interferes with the received signals, affecting interference measurements. Therefore, the analysis and suppression of backscattered light are crucial issues that must be considered in the telescope. In this paper, the results of a numerical model and simulation analysis are compared to analyze the stray light performance of two existing optical design schemes for telescopes. The contributions of backscattered light from the four mirrors have been determined, and the surface roughness indicators for optical elements meeting the stray light requirements have also been derived. This work lays the foundation for the manufacturing of prototype telescopes.
- 21 February 2025
- Published by Optica Publishing Group in Applied Optics
- Vol. 64 (7) , 1639-1645
Performance comparison of two telescope configurations for backscattered light in space gravitational wave detection
In space-based gravitational wave detection telescopes, backscattered light generated by the optical elements of the telescope interferes with the received signals, affecting interference measurements. Therefore, the analysis and suppression of backscattered light are crucial issues that must be considered in the telescope. In this paper, the results of a numerical model and simulation analysis are compared to analyze the stray light performance of two existing optical design schemes for telescopes. The contributions of backscattered light from the four mirrors have been determined, and the surface roughness indicators for optical elements meeting the stray light requirements have also been derived. This work lays the foundation for the manufacturing of prototype telescopes.
- 7 January 2025
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 42 (3) , 035002
Dimensional stability sensitivity analysis based on transfer function models for telescope in space gravitational wave detectors
The telescope serves as a vital component of the space gravitational wave detector. In TianQin project, the exceptional dimensional stability of the telescope must be better than 1 pm Hz−1/2 @0.1 mHz–1 Hz. To assess the in-orbit dimensional stability of the telescope, a transfer function model was developed to evaluate the stability of the primary and secondary mirror spacing structure, considering the three primary thermal sources. It has been discovered that the stability of the spacer structure is influenced not only by the thermal expansion coefficient of the material but also by its heat capacity, density, and frequency band. Zerodur offers distinct advantages in terms of overall thermal performance. Specifically, the stability of the spacer constructed by it can be effectively controlled at 0.14 pm Hz−1/2@0.1 mHz–1 Hz, which is an achievement in the field of ultra-stability structure design.
- 7 January 2025
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 42 (3) , 035002
Dimensional stability sensitivity analysis based on transfer function models for telescope in space gravitational wave detectors
The telescope serves as a vital component of the space gravitational wave detector. In TianQin project, the exceptional dimensional stability of the telescope must be better than 1 pm Hz−1/2 @0.1 mHz–1 Hz. To assess the in-orbit dimensional stability of the telescope, a transfer function model was developed to evaluate the stability of the primary and secondary mirror spacing structure, considering the three primary thermal sources. It has been discovered that the stability of the spacer structure is influenced not only by the thermal expansion coefficient of the material but also by its heat capacity, density, and frequency band. Zerodur offers distinct advantages in terms of overall thermal performance. Specifically, the stability of the spacer constructed by it can be effectively controlled at 0.14 pm Hz−1/2@0.1 mHz–1 Hz, which is an achievement in the field of ultra-stability structure design.
- 1 January 2025
- Published by Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences in Chinese Optics
- Vol. 18 (4) , 889-898
Flatness detection method of splicing detector based on channel spectral dispersion
The predecessor of China Optics was China Optics and Applied Optics Digest, which was founded in 1985. At that time, it was the only retrieval journal in the field of optics in China. At the end of 2008, China Optics and Applied Optics Digest was renamed 《中国光学》的前身是1985年创办的《中国光学与应用光学文摘》,当时是国内光学领域唯一的检索刊物。2008年底《中国光学与应用光学文摘》转型更名为《中国光学与应用光学》期刊,刊载内容突破了文摘的限制,正式成为学术刊物。
- 1 January 2025
- Published by Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences in Chinese Optics
- Vol. 18 (4) , 889-898
Flatness detection method of splicing detector based on channel spectral dispersion
The predecessor of China Optics was China Optics and Applied Optics Digest, which was founded in 1985. At that time, it was the only retrieval journal in the field of optics in China. At the end of 2008, China Optics and Applied Optics Digest was renamed 《中国光学》的前身是1985年创办的《中国光学与应用光学文摘》,当时是国内光学领域唯一的检索刊物。2008年底《中国光学与应用光学文摘》转型更名为《中国光学与应用光学》期刊,刊载内容突破了文摘的限制,正式成为学术刊物。