Yuwei Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yuwei Wu has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Hongchao Zhao
Sun Yat-sen University
3 shared publications - Jianing Wu
School of Aeronautics and Astronautics, Sun Yat-sen University, Shenzhen 518107, China
3 shared publications Guoye Chen
2 shared publicationsJiahao Wei
2 shared publications- Jun Lyu
School of Advanced Manufacturing, Sun Yat-Sen University, Shenzhen, People’s Republic of China
2 shared publications Weizhou Hong
2 shared publications
Latest Publications
- 24 November 2026
- Published by Elsevier in International Journal of Mechanical Sciences
Generative Inverse Design of Quasi-Zero-Stiffness Cells for Prescribed Loads
- 24 November 2026
- Published by Elsevier in International Journal of Mechanical Sciences
Generative Inverse Design of Quasi-Zero-Stiffness Cells for Prescribed Loads
- Open Access
- 3 July 2026
- Published by Elsevier in SSRN Electronic Journal
Enhancing the Load-Bearing Capacity of Revolved Quasi-Zero Stiffness Cells Using Generative Adversarial Networks
Low-frequency broadband vibration isolation is critical for precision manufacturing and aerospace applications, yet traditional linear isolators suffer from the fundamental trade-off between high load capacity and low stiffness. Rotational quasi-zero stiffness (QZS) cells using Non-Uniform Rational B-Splines (NURBS) offer a promising high-static-low-dynamic-stiffness (HSLDS) solution. However, NURBS’ high-dimensional parameter space renders conventional forward design inefficient and prone to local optima, while existing inverse methods are limited to narrow load ranges and lack generalization capability. This paper presents an end-to-end Generative Adversarial Network (GAN)-based inverse design framework for QZS cells, directly generating geometry configurations from target loads (50–140 N). Validation on eight designed cells shows a maximum load-bearing ratio of 218, ultra-broadband isolation from 5 Hz to 300 Hz, and a minimum transmissibility of -49.68 dB. A Young’s modulus-normalized dimensionless load indicator Ψ is introduced, enabling evaluation of the cross-material transferability of WGAN-generated geometries across photocurable resins, mitigating the limitation of single-material evaluation in prior studies. This framework establishes a scalable paradigm for rapid, material-adaptive customized design of high-performance 3D-printed QZS vibration isolators.
- 3 July 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessEnhancing the Load-Bearing Capacity of Revolved Quasi-Zero Stiffness Cells Using Generative Adversarial Networks
Low-frequency broadband vibration isolation is critical for precision manufacturing and aerospace applications, yet traditional linear isolators suffer from the fundamental trade-off between high load capacity and low stiffness. Rotational quasi-zero stiffness (QZS) cells using Non-Uniform Rational B-Splines (NURBS) offer a promising high-static-low-dynamic-stiffness (HSLDS) solution. However, NURBS’ high-dimensional parameter space renders conventional forward design inefficient and prone to local optima, while existing inverse methods are limited to narrow load ranges and lack generalization capability. This paper presents an end-to-end Generative Adversarial Network (GAN)-based inverse design framework for QZS cells, directly generating geometry configurations from target loads (50–140 N). Validation on eight designed cells shows a maximum load-bearing ratio of 218, ultra-broadband isolation from 5 Hz to 300 Hz, and a minimum transmissibility of -49.68 dB. A Young’s modulus-normalized dimensionless load indicator Ψ is introduced, enabling evaluation of the cross-material transferability of WGAN-generated geometries across photocurable resins, mitigating the limitation of single-material evaluation in prior studies. This framework establishes a scalable paradigm for rapid, material-adaptive customized design of high-performance 3D-printed QZS vibration isolators.
- 30 December 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (2) , 025106
Flexure hinge design and optimization of a high-precision force sensor for the test mass grabbing position and release mechanism
Space-based gravitational wave detection is expected to open an observation window for gravitational wave sources in the low-frequency band. The inertial sensor is one of the key components of such detectors. To ensure that the test mass can accurately follow a geodesic trajectory, it must be precisely released within the confined vacuum chamber of the detector. This imposes specific requirements on the high integration and accuracy of contact force measurement during the grabbing and release process. This paper proposes a force sensor design employing double circular notch flexure hinges. A comparative study of single and double circular notch flexure hinge configurations reveals significant differences in terms of the distribution of maximum strain areas and the magnitude of the area-averaged strain. The double circular notch design can produce an increase in area-averaged strain of up to 351%. This study establishes a design methodology that defines a feasible range of flexure hinge parameters and their associated bonding areas. The analysis reveals that an optimal strain gauge spacing of 4–7 mm or 9-12 mm is essential for preventing bonding overlap within confined spaces. Furthermore, a force sensor calibration device was developed. Experimental characterization demonstrated that the sensor provides a full scale of 10 N, an accuracy of 0.02 N (±0.2% F.S.), a rapid response time of 12 ms, low hysteresis (0.15% F.S.) and fine repeatability (±0.2% F.S.). This study not only provides a design scheme for flexure hinge of force sensors within confined space for space-based gravitational wave detection but also presents a framework for the design of micro force sensors that satisfy the stringent requirements of aerospace and extreme industrial applications.
- 30 December 2025
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 37 (2) , 025106
Flexure hinge design and optimization of a high-precision force sensor for the test mass grabbing position and release mechanism
Space-based gravitational wave detection is expected to open an observation window for gravitational wave sources in the low-frequency band. The inertial sensor is one of the key components of such detectors. To ensure that the test mass can accurately follow a geodesic trajectory, it must be precisely released within the confined vacuum chamber of the detector. This imposes specific requirements on the high integration and accuracy of contact force measurement during the grabbing and release process. This paper proposes a force sensor design employing double circular notch flexure hinges. A comparative study of single and double circular notch flexure hinge configurations reveals significant differences in terms of the distribution of maximum strain areas and the magnitude of the area-averaged strain. The double circular notch design can produce an increase in area-averaged strain of up to 351%. This study establishes a design methodology that defines a feasible range of flexure hinge parameters and their associated bonding areas. The analysis reveals that an optimal strain gauge spacing of 4–7 mm or 9-12 mm is essential for preventing bonding overlap within confined spaces. Furthermore, a force sensor calibration device was developed. Experimental characterization demonstrated that the sensor provides a full scale of 10 N, an accuracy of 0.02 N (±0.2% F.S.), a rapid response time of 12 ms, low hysteresis (0.15% F.S.) and fine repeatability (±0.2% F.S.). This study not only provides a design scheme for flexure hinge of force sensors within confined space for space-based gravitational wave detection but also presents a framework for the design of micro force sensors that satisfy the stringent requirements of aerospace and extreme industrial applications.
- 28 January 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part O: Journal of Risk and Reliability
- Vol. 239 (5) , 889-899
Reliability evaluation of the grabbing, positioning, and release mechanism for gravitational wave detection
Predicting reliability is an essential part of the design phase for ensuring mission success. In the realm of gravitational wave detection, the integrity and dependability of the Grabbing, Positioning, and Release Mechanism (GPRM) are paramount for its effective space-based deployment. However, predicting reliability of a complex mechanical system like the GPRM during the design phase poses significant challenges due to the harsh and variable conditions of the space environment. This paper addresses these challenges by proposing a reliability evaluation method that combines the stochastic and degradation characteristics of the GPRM, according to which both randomness of the stud position and the degradation of the piezoelectric coefficient are considered. Failure criteria are established based on mission performance indicators, and the Kaplan-Meier estimator is used to analyze the mechanism reliability of the GPRM over time. The result predicts that the reliability of the GPRM is around 0.8 after 10 7 operating cycles. This finding demonstrates that our proposed method is an effective approach for evaluating reliability, offering valuable insights for ensuring the long-term performance and successful operation of precision mechanisms.
- 28 January 2025
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part O: Journal of Risk and Reliability
- Vol. 239 (5) , 889-899
Reliability evaluation of the grabbing, positioning, and release mechanism for gravitational wave detection
Predicting reliability is an essential part of the design phase for ensuring mission success. In the realm of gravitational wave detection, the integrity and dependability of the Grabbing, Positioning, and Release Mechanism (GPRM) are paramount for its effective space-based deployment. However, predicting reliability of a complex mechanical system like the GPRM during the design phase poses significant challenges due to the harsh and variable conditions of the space environment. This paper addresses these challenges by proposing a reliability evaluation method that combines the stochastic and degradation characteristics of the GPRM, according to which both randomness of the stud position and the degradation of the piezoelectric coefficient are considered. Failure criteria are established based on mission performance indicators, and the Kaplan-Meier estimator is used to analyze the mechanism reliability of the GPRM over time. The result predicts that the reliability of the GPRM is around 0.8 after 10 7 operating cycles. This finding demonstrates that our proposed method is an effective approach for evaluating reliability, offering valuable insights for ensuring the long-term performance and successful operation of precision mechanisms.