Meirong Qi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Meirong Qi has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Jing Yan
Xi’an Jiaotong University
4 shared publications - Jianhua Wang
School of Electrical Engineering, Xian Jiaotong University, Xian, China
3 shared publications - Yanze Wu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
3 shared publications - Yingsan Geng
State Key Laboratory of Electrical Insulation and Power Equipment, Department of Electrical Engineering, Xian Jiaotong University, Xian, China
3 shared publications - Zhuofan Xu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
3 shared publications - Guoqing Sui
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
2 shared publications
Latest Publications
- Open Access
- 9 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4036
Mechanical Fault Diagnosis of High-Voltage Circuit Breakers with Dynamic Multi-Attention Graph Convolutional Networks Based on Adaptive Graph Construction
With the rapid development of deep learning, its powerful capabilities make it possible to perform mechanical fault diagnosis of high-voltage circuit breakers (HVCBs). Among deep learning approaches, the convolutional neural network is widely used. However, while it can extract features effectively, it also has some limitations. Specifically, it depends on a large number of training data and only takes data information into account without considering structural information. These shortcomings lead to unused information and unsatisfactory model results. To address these shortcomings, this paper proposes AKNN-DMGCN, a novel dynamic multi-attention graph convolutional network based on an adaptively constructed graph, which can achieve high accuracy and robust mechanical fault diagnosis of HVCBs. First, a novel adaptive k-nearest neighbor (AKNN) graph construction method is proposed to construct informative graphs. The AKNN method can mine the relationship between the original data samples and utilize the data and label information. Thus, it has high fault tolerance to noise signals and can construct a structure graph with rich and accurate information, which can improve the overall model performance. Then, a dynamic multi-attention graph convolutional network (DMGCN) is applied for mechanical fault diagnosis of HVCBs. DMGCN fully utilizes structural and numerical information representing HVCB signals to perform classification. DMGCN has a dynamic multi-attention mechanism with strong expressive ability, which allows it to achieve high diagnostic accuracy. The experimental results indicate that the accuracy of AKNN-DMGCN reaches 97.22% on a balanced dataset and 95.01% on an imbalanced dataset, which demonstrates that the proposed method is effective for both balanced and imbalanced samples.
- 9 May 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (10) , 4036
Open AccessMechanical Fault Diagnosis of High-Voltage Circuit Breakers with Dynamic Multi-Attention Graph Convolutional Networks Based on Adaptive Graph Construction
With the rapid development of deep learning, its powerful capabilities make it possible to perform mechanical fault diagnosis of high-voltage circuit breakers (HVCBs). Among deep learning approaches, the convolutional neural network is widely used. However, while it can extract features effectively, it also has some limitations. Specifically, it depends on a large number of training data and only takes data information into account without considering structural information. These shortcomings lead to unused information and unsatisfactory model results. To address these shortcomings, this paper proposes AKNN-DMGCN, a novel dynamic multi-attention graph convolutional network based on an adaptively constructed graph, which can achieve high accuracy and robust mechanical fault diagnosis of HVCBs. First, a novel adaptive k-nearest neighbor (AKNN) graph construction method is proposed to construct informative graphs. The AKNN method can mine the relationship between the original data samples and utilize the data and label information. Thus, it has high fault tolerance to noise signals and can construct a structure graph with rich and accurate information, which can improve the overall model performance. Then, a dynamic multi-attention graph convolutional network (DMGCN) is applied for mechanical fault diagnosis of HVCBs. DMGCN fully utilizes structural and numerical information representing HVCB signals to perform classification. DMGCN has a dynamic multi-attention mechanism with strong expressive ability, which allows it to achieve high diagnostic accuracy. The experimental results indicate that the accuracy of AKNN-DMGCN reaches 97.22% on a balanced dataset and 95.01% on an imbalanced dataset, which demonstrates that the proposed method is effective for both balanced and imbalanced samples.
- Open Access
- 10 April 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (8) , 3183
Intelligent Mechanical Fault Diagnosis Method for High-Voltage Circuit Breakers Based on Grey Wolf Optimization and Multi-Grained Cascade Forest Algorithms
High-voltage circuit breakers (HVCBs) handle the important tasks of controlling and safeguarding electricity networks. In the case of insufficient data samples, improving the accuracy of the traditional HVCB mechanical fault diagnosis method is difficult, so it poses challenges in meeting performance requirements for mechanical fault diagnosis. In this study, a HVCB fault diagnosis method is introduced. It utilizes a combination of grey wolf optimization (GWO) and multi-grained cascade forest (gcForest) algorithms to resolve these issues and improve the accuracy of HVCB mechanical fault diagnosis. To simplify the original vibration signal, the input feature quantity for the fault diagnosis method is obtained by calculating the energy entropy of the wavelet packet decomposition. The GWO algorithm is employed to optimize the parameters of the gcForest model, leading to identification of the optimum parameter configuration. Subsequently, the diagnostic effect in the case of a small sample size was analyzed through a VS1 vacuum circuit breaker example, and the accuracy reached 95.89%. In the case of unbalanced samples, further analysis and comparison with different methods confirm the feasibility and efficiency of the combination of GWO and gcForest algorithms. This study provides an effective solution for the diagnosis of mechanical faults in HVCBs.
- 10 April 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (8) , 3183
Open AccessIntelligent Mechanical Fault Diagnosis Method for High-Voltage Circuit Breakers Based on Grey Wolf Optimization and Multi-Grained Cascade Forest Algorithms
High-voltage circuit breakers (HVCBs) handle the important tasks of controlling and safeguarding electricity networks. In the case of insufficient data samples, improving the accuracy of the traditional HVCB mechanical fault diagnosis method is difficult, so it poses challenges in meeting performance requirements for mechanical fault diagnosis. In this study, a HVCB fault diagnosis method is introduced. It utilizes a combination of grey wolf optimization (GWO) and multi-grained cascade forest (gcForest) algorithms to resolve these issues and improve the accuracy of HVCB mechanical fault diagnosis. To simplify the original vibration signal, the input feature quantity for the fault diagnosis method is obtained by calculating the energy entropy of the wavelet packet decomposition. The GWO algorithm is employed to optimize the parameters of the gcForest model, leading to identification of the optimum parameter configuration. Subsequently, the diagnostic effect in the case of a small sample size was analyzed through a VS1 vacuum circuit breaker example, and the accuracy reached 95.89%. In the case of unbalanced samples, further analysis and comparison with different methods confirm the feasibility and efficiency of the combination of GWO and gcForest algorithms. This study provides an effective solution for the diagnosis of mechanical faults in HVCBs.
- Open Access
Subdomain Adaptation Capsule Network for Partial Discharge Diagnosis in Gas-Insulated Switchgear
Deep learning methods, especially convolutional neural networks (CNNs), have achieved good results in the partial discharge (PD) diagnosis of gas-insulated switchgear (GIS) in the laboratory. However, the relationship of features ignored in CNNs and the heavy dependance on the amount of sample data make it difficult for the model developed in the laboratory to achieve high-precision, robust diagnosis of PD in the field. To solve these problems, a subdomain adaptation capsule network (SACN) is adopted for PD diagnosis in GIS. First, the feature information is effectively extracted by using a capsule network, which improves feature representation. Then, subdomain adaptation transfer learning is used to accomplish high diagnosis performance on the field data, which alleviates the confusion of different subdomains and matches the local distribution at the subdomain level. Experimental results demonstrate that the accuracy of the SACN in this study reaches 93.75% on the field data. The SACN has better performance than traditional deep learning methods, indicating that the SACN has potential application value in PD diagnosis of GIS.
Open AccessSubdomain Adaptation Capsule Network for Partial Discharge Diagnosis in Gas-Insulated Switchgear
Deep learning methods, especially convolutional neural networks (CNNs), have achieved good results in the partial discharge (PD) diagnosis of gas-insulated switchgear (GIS) in the laboratory. However, the relationship of features ignored in CNNs and the heavy dependance on the amount of sample data make it difficult for the model developed in the laboratory to achieve high-precision, robust diagnosis of PD in the field. To solve these problems, a subdomain adaptation capsule network (SACN) is adopted for PD diagnosis in GIS. First, the feature information is effectively extracted by using a capsule network, which improves feature representation. Then, subdomain adaptation transfer learning is used to accomplish high diagnosis performance on the field data, which alleviates the confusion of different subdomains and matches the local distribution at the subdomain level. Experimental results demonstrate that the accuracy of the SACN in this study reaches 93.75% on the field data. The SACN has better performance than traditional deep learning methods, indicating that the SACN has potential application value in PD diagnosis of GIS.
- 10 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-12
Collaborative Domain Adaptation Network for Partial Discharge Source Localization in Gas-Insulated Switchgear
Abnormal discharge in gas-insulated switchgear (GIS) is a key cause of insulation failure, and it is also an external manifestation of insulation defects. Sensitive discharge source localization is an important goal of GIS partial discharge (PD) monitoring. However, most existing GIS PD source localization methods rely on time-delay estimation, which not only requires a high-precision synchronous sampling device but also suffers from serious interference. To this end, a collaborative domain adaptation network (CDAN) is proposed for GIS PD source localization. First, a synchronous squeezing wavelet transform is introduced to filter out the noise, eliminating the influence of noise on GIS PD source localization. Then, one-dimensional attention convolutional neural network is constructed to ensure that discriminative temporal fine-grained information is extracted. Next, a CDAN is proposed to transfer the localization knowledge learned from the simulation to actual GIS and achieve high-precision localization through domain matching and alignment. The results demonstrate that the error of the CDAN proposed is only 19.87 cm, which is considerably better than that from other methods. This work provides a reference solution for GIS PD source localization.
- 10 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-12
Collaborative Domain Adaptation Network for Partial Discharge Source Localization in Gas-Insulated Switchgear
Abnormal discharge in gas-insulated switchgear (GIS) is a key cause of insulation failure, and it is also an external manifestation of insulation defects. Sensitive discharge source localization is an important goal of GIS partial discharge (PD) monitoring. However, most existing GIS PD source localization methods rely on time-delay estimation, which not only requires a high-precision synchronous sampling device but also suffers from serious interference. To this end, a collaborative domain adaptation network (CDAN) is proposed for GIS PD source localization. First, a synchronous squeezing wavelet transform is introduced to filter out the noise, eliminating the influence of noise on GIS PD source localization. Then, one-dimensional attention convolutional neural network is constructed to ensure that discriminative temporal fine-grained information is extracted. Next, a CDAN is proposed to transfer the localization knowledge learned from the simulation to actual GIS and achieve high-precision localization through domain matching and alignment. The results demonstrate that the error of the CDAN proposed is only 19.87 cm, which is considerably better than that from other methods. This work provides a reference solution for GIS PD source localization.