Yansong Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yansong Wang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Wendong Zhang
North University of China
2 shared publications - Changde He
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan 030051, China
1 shared publication - Dan Gao
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan, China
1 shared publication - Guojun Zhang
North University of China
1 shared publication Hongliang Wang
1 shared publication- Hongliang Wang
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Measurement Technology and Instrument, North University of China, Taiyuan, China
1 shared publication
Latest Publications
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-18
Rapid High-Resolution Breast Imaging With Ring-Array Multi-Subarray Synthetic-Aperture Frequency-Domain Ultrasound Computed Tomography Method
Ultrasound computed tomography (USCT) using ring array technology has shown great potential in breast diagnosis. This study addresses the problems of low imaging resolution and long acquisition time in USCT for breast diagnosis by proposing a frequency domain imaging method based on a ring array and multi-subarray synthetic aperture. This method achieves omnidirectional transmission and reception through beam focusing synthesis, enabling tomographic scanning, supporting complete 3D CT reconstruction, and simulating the performance of a large-aperture system with a small array, achieving sub-millimeter-level imaging resolution. By combining a frequency delay-compensated beamforming method and a designed adjustment strategy, effective signal components are filtered from the large amount of data received by the ring array, completing lossless signal conversion between the time and frequency domains, reducing the reconstruction time to less than 6 seconds, a 7.4-fold improvement over traditional time-domain methods and approximately 2.6 times faster than existing clinical breast CT systems. Experiments show that The breast tissue membrane reconstruction demonstrates high fidelity, and Preliminary clinical pilot study and MRI results are trend-level agreement in boundary, and spatial distribution, validating the effectiveness and accuracy of this method in clinical practice.
- 26 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-18
Rapid High-Resolution Breast Imaging With Ring-Array Multi-Subarray Synthetic-Aperture Frequency-Domain Ultrasound Computed Tomography Method
Ultrasound computed tomography (USCT) using ring array technology has shown great potential in breast diagnosis. This study addresses the problems of low imaging resolution and long acquisition time in USCT for breast diagnosis by proposing a frequency domain imaging method based on a ring array and multi-subarray synthetic aperture. This method achieves omnidirectional transmission and reception through beam focusing synthesis, enabling tomographic scanning, supporting complete 3D CT reconstruction, and simulating the performance of a large-aperture system with a small array, achieving sub-millimeter-level imaging resolution. By combining a frequency delay-compensated beamforming method and a designed adjustment strategy, effective signal components are filtered from the large amount of data received by the ring array, completing lossless signal conversion between the time and frequency domains, reducing the reconstruction time to less than 6 seconds, a 7.4-fold improvement over traditional time-domain methods and approximately 2.6 times faster than existing clinical breast CT systems. Experiments show that The breast tissue membrane reconstruction demonstrates high fidelity, and Preliminary clinical pilot study and MRI results are trend-level agreement in boundary, and spatial distribution, validating the effectiveness and accuracy of this method in clinical practice.
- 13 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Design and Fabrication of Hollow Mushroom-Like Cilia MEMS Vector Hydrophone
Vector hydrophone is the core equipment of underwater acoustic detection. Aiming at the problem of low sensitivity and short detection distance of existing vector hydrophone. In this paper, a hollow mushroom-like cilia sensitive structure is designed to optimize the hydrophone sensitive unit. The optimal size of the hollow mushroom-like cilia MEMS vector hydrophone (MCVH) microstructure was determined by COMSOL5.6 simulation. The hollow structure is adopted, which not only ensures the working bandwidth of the hydrophone is 20Hz-1000Hz, but also improves the sensitivity of the hydrophone by increasing the receiving area of the sound wave. The test results show that the hollow structure has obvious "8" directivity, and the pit depth of the "8" directivity larger than 40dB at 315Hz. Meantime, the sensitivity of MCVH can reach -180.9dB at 1000Hz. Compared with Ciliary MEMS vector hydrophone(CVH), the sensitivity is improved by 16.8dB.
- 13 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Design and Fabrication of Hollow Mushroom-Like Cilia MEMS Vector Hydrophone
Vector hydrophone is the core equipment of underwater acoustic detection. Aiming at the problem of low sensitivity and short detection distance of existing vector hydrophone. In this paper, a hollow mushroom-like cilia sensitive structure is designed to optimize the hydrophone sensitive unit. The optimal size of the hollow mushroom-like cilia MEMS vector hydrophone (MCVH) microstructure was determined by COMSOL5.6 simulation. The hollow structure is adopted, which not only ensures the working bandwidth of the hydrophone is 20Hz-1000Hz, but also improves the sensitivity of the hydrophone by increasing the receiving area of the sound wave. The test results show that the hollow structure has obvious "8" directivity, and the pit depth of the "8" directivity larger than 40dB at 315Hz. Meantime, the sensitivity of MCVH can reach -180.9dB at 1000Hz. Compared with Ciliary MEMS vector hydrophone(CVH), the sensitivity is improved by 16.8dB.