Weikai Sun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Weikai Sun has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chongxing Zhang
Xi’an Jiaotong University
1 shared publication - Kexie Hu
Xi’an Jiaotong University
1 shared publication Kun Peng
School of Materials Science and Engineering Zhejiang Sci‐Tech University Hangzhou 310018 P. R. China
1 shared publication- Ming Dong
Xi’an Jiaotong University
1 shared publication - Ming Ren
Xi’an Jiaotong University
1 shared publication Minhao Yang
Institute of Energy Power Innovation North China Electric Power University Beijing 102206 P. R. China
1 shared publication
Latest Publications
- 18 August 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (16) , 160504
Accurate Internal Temperature Estimation for Lithium-Ion Battery Based on Modified Electro-Thermal Coupling Model with Online Electrochemical Impedance Spectroscopy Measurement
Accurate estimation of lithium-ion battery internal temperature is crucial for ensuring safety, and longevity, particularly under high-rate operating conditions where significant internal-to-surface temperature gradients develop. The present study establishes a modified electro‐thermal coupling model that integrates an equivalent circuit model (ECM) with a lumped‐parameter thermal model (LPTM) in a dynamic framework. Initially, both models utilized static parameters. In the modified approach, the ohmic resistance R 0 and polarization resistance R 1 of the ECM are dynamically identified through electrochemical impedance spectroscopy (EIS). Concurrently, the heat generation rate Q total is calculated from the Bernardi model, and the resulting internal temperature T c is fed back to the ECM, where its parameters are corrected via the Arrhenius relation, thereby achieving real‐time parameter updating under varying operating conditions. The coupled model is formulated using a thermal resistance‐capacitance network and solved with a first‐order transient thermal equation. Furthermore, an adaptive extended Kalman filter (AEKF) is applied to refine the estimation, significantly enhancing the accuracy and robustness of internal temperature prediction. Experimental validation under 1C/2C constant-current discharge demonstrates a maximum absolute error of 0.45 °C and a relative error below 0.69%. The proposed coupled model offers an effective solution for internal temperature monitoring in battery thermal management systems.
- 18 August 2026
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 173 (16) , 160504
Accurate Internal Temperature Estimation for Lithium-Ion Battery Based on Modified Electro-Thermal Coupling Model with Online Electrochemical Impedance Spectroscopy Measurement
Accurate estimation of lithium-ion battery internal temperature is crucial for ensuring safety, and longevity, particularly under high-rate operating conditions where significant internal-to-surface temperature gradients develop. The present study establishes a modified electro‐thermal coupling model that integrates an equivalent circuit model (ECM) with a lumped‐parameter thermal model (LPTM) in a dynamic framework. Initially, both models utilized static parameters. In the modified approach, the ohmic resistance R 0 and polarization resistance R 1 of the ECM are dynamically identified through electrochemical impedance spectroscopy (EIS). Concurrently, the heat generation rate Q total is calculated from the Bernardi model, and the resulting internal temperature T c is fed back to the ECM, where its parameters are corrected via the Arrhenius relation, thereby achieving real‐time parameter updating under varying operating conditions. The coupled model is formulated using a thermal resistance‐capacitance network and solved with a first‐order transient thermal equation. Furthermore, an adaptive extended Kalman filter (AEKF) is applied to refine the estimation, significantly enhancing the accuracy and robustness of internal temperature prediction. Experimental validation under 1C/2C constant-current discharge demonstrates a maximum absolute error of 0.45 °C and a relative error below 0.69%. The proposed coupled model offers an effective solution for internal temperature monitoring in battery thermal management systems.
- 19 April 2023
- Published by Wiley in Macromolecular Rapid Communications
- Vol. 44 (12) , e2200956
All‐Organic Hyper‐Crosslinked Polymer/Polyimide Composite Films with Ultralow High‐Frequency Dielectric Constant
The ever increasing demand for high‐speed communication at high frequency promotes the rapid development of low‐dielectric polymer films. Aromatic polyimide (PI) has been widely used as the main dielectrics in the flexible circuit board due to its excellent dielectric, mechanical, and thermal properties. Nevertheless, the dielectric constant of PI films at a high frequency range (several GHz) is relatively high and cannot satisfy the requirement of high‐frequency communication. On this basis, a hyper‐crosslinked polymer (HCP) and fabricated all‐organic HCP/PI composite films through a physical blending method is synthesized. The porous structure of HCP is helpful to reduce the dielectric constant of PI matrix. The effects of HCP loadings on the dielectric, mechanical, and thermal properties of HCP/PI composite films are systematically investigated. The dielectric constants of the composite films can be reduced to 1.6–1.8 in the frequency range of 8.2–9.6 GHz when the HCP content reached 10 wt.%. The proposed method in this work is simple and effective to reduce the dielectric constant of PI and can be easily extended to other organic component‐filled PI systems.
- 19 April 2023
- Published by Wiley in Macromolecular Rapid Communications
- Vol. 44 (12) , e2200956
All‐Organic Hyper‐Crosslinked Polymer/Polyimide Composite Films with Ultralow High‐Frequency Dielectric Constant
The ever increasing demand for high‐speed communication at high frequency promotes the rapid development of low‐dielectric polymer films. Aromatic polyimide (PI) has been widely used as the main dielectrics in the flexible circuit board due to its excellent dielectric, mechanical, and thermal properties. Nevertheless, the dielectric constant of PI films at a high frequency range (several GHz) is relatively high and cannot satisfy the requirement of high‐frequency communication. On this basis, a hyper‐crosslinked polymer (HCP) and fabricated all‐organic HCP/PI composite films through a physical blending method is synthesized. The porous structure of HCP is helpful to reduce the dielectric constant of PI matrix. The effects of HCP loadings on the dielectric, mechanical, and thermal properties of HCP/PI composite films are systematically investigated. The dielectric constants of the composite films can be reduced to 1.6–1.8 in the frequency range of 8.2–9.6 GHz when the HCP content reached 10 wt.%. The proposed method in this work is simple and effective to reduce the dielectric constant of PI and can be easily extended to other organic component‐filled PI systems.