Milovan Kotur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Milovan Kotur has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Petar Gvero
Faculty of Mechanical Engineering University of Banja Luka 78000 Banja Luka Bosnia and Herzegovina
6 shared publications - Darija Gajić
Faculty of Architecture, Civil Engineering and Geodesy, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
5 shared publications - Milan Pupčević
Faculty of Mechanical Engineering, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
4 shared publications - Ljubiša Preradović
Faculty of Architecture, Civil Engineering and Geodesy, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
3 shared publications - Saša Papuga
University of Banja Luka
3 shared publications - Biljana Antunović
Faculty of Architecture, Civil Engineering and Geodesy, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
2 shared publications
Latest Publications
- Open Access
Analysis of Indoor Air Quality and Occupant Perception Under Different Mechanical Ventilation Operational Modes in a University Amphitheater
This paper presents an analysis of indoor air quality (IAQ) and occupant perception under different mechanical ventilation operational modes in a university amphitheater. Indoor environmental parameters, including air temperature, relative humidity, indoor air velocity, and CO2 concentration, were measured in accordance with ISO 7726. Ventilation performance and outdoor air supply requirements were evaluated according to BAS EN 16798-1 and ASHRAE 62.1, while thermal comfort interpretation followed ISO 7730. In parallel, a questionnaire survey was conducted to assess occupants’ perceptions of indoor air quality and its influence on concentration under different ventilation operating conditions. The results showed that CO2 concentrations occasionally exceeded 1000 ppm during extended occupancy periods but remained below 800 ppm for more than 60% of the measurement time. According to BAS EN 16798-1, the indoor environment was predominantly classified as Category I based on the indoor–outdoor CO2 concentration difference. Survey responses indicated that most students perceived the indoor air as clean, while 67% reported that IAQ influenced their ability to concentrate. The findings highlight the importance of occupancy-related ventilation control strategies in large educational spaces and demonstrate the potential for balancing indoor air quality and energy efficiency through appropriate ventilation system operation. The presented methodology may support future development of data-driven approaches for optimizing mechanical ventilation performance in university buildings.
Open AccessAnalysis of Indoor Air Quality and Occupant Perception Under Different Mechanical Ventilation Operational Modes in a University Amphitheater
This paper presents an analysis of indoor air quality (IAQ) and occupant perception under different mechanical ventilation operational modes in a university amphitheater. Indoor environmental parameters, including air temperature, relative humidity, indoor air velocity, and CO2 concentration, were measured in accordance with ISO 7726. Ventilation performance and outdoor air supply requirements were evaluated according to BAS EN 16798-1 and ASHRAE 62.1, while thermal comfort interpretation followed ISO 7730. In parallel, a questionnaire survey was conducted to assess occupants’ perceptions of indoor air quality and its influence on concentration under different ventilation operating conditions. The results showed that CO2 concentrations occasionally exceeded 1000 ppm during extended occupancy periods but remained below 800 ppm for more than 60% of the measurement time. According to BAS EN 16798-1, the indoor environment was predominantly classified as Category I based on the indoor–outdoor CO2 concentration difference. Survey responses indicated that most students perceived the indoor air as clean, while 67% reported that IAQ influenced their ability to concentrate. The findings highlight the importance of occupancy-related ventilation control strategies in large educational spaces and demonstrate the potential for balancing indoor air quality and energy efficiency through appropriate ventilation system operation. The presented methodology may support future development of data-driven approaches for optimizing mechanical ventilation performance in university buildings.
- Open Access
- 3 August 2026
- Published by Acadlore Publishing Services Limited in Journal of Sustainability for Energy
- Vol. 5 (3) , 195-212
Energy Renovation of a Hospital Support Building for Sustainable Energy Use: Scenario Evaluation and Investment Trade-Offs
- 3 August 2026
- Published by Acadlore Publishing Services Limited in Journal of Sustainability for Energy
- Vol. 5 (3) , 195-212
Open AccessEnergy Renovation of a Hospital Support Building for Sustainable Energy Use: Scenario Evaluation and Investment Trade-Offs
- Open Access
- 3 February 2026
- Published by "IMS" Vogosca in Science, Engineering and Technology
- Vol. 6 (S1) , 21-37
Development of an Adaptive Multi-Criteria Optimization Framework Using the PSI Method: Validation via Thermal Insulation Selection
Multi-criteria optimization is primarily utilized to rank various alternatives and project types. However, the question arises: is it possible to use the multi-criteria optimization process for something more than that, in terms of determining the actual set of optimal criteria and creating optimal paths of their changes according to desired constraints? In this regard, it is necessary to find a connection between the output provided by multi-criteria optimization method itself and a hypothetical alternative that represents the current optimal alternative, referred to as a synthetic profile or transit optimum, which does not represent any initial alternative in the optimization matrix. Such an actual transit alternative is formed by the mutual influence of all factors in the decision matrix, but also depends on the multi-criteria optimization process itself. This requires the creation of a mathematical feedback loop between the optimization process and the redistribution of all alternatives according to the criteria, to create a new transit optimal set of criteria. As a representative method for multi-criteria optimization, the PSI (Preference Selection Index) method was selected because of its advantages in terms of its integrated procedure for calculating criteria weights and its objectivity in categorization. The proposed adaptive PSI framework introduces a synthetic profile that enables iterative feedback and two-stage optimization, transforming the classical static ranking into a dynamic adaptive process with a clear methodological advancement over existing MCDM techniques. The overall concept was tested on the optimization of thermal insulation thickness for walls under the conditions of Bosnia and Herzegovina.
- 3 February 2026
- Published by "IMS" Vogosca in Science, Engineering and Technology
- Vol. 6 (S1) , 21-37
Open AccessDevelopment of an Adaptive Multi-Criteria Optimization Framework Using the PSI Method: Validation via Thermal Insulation Selection
Multi-criteria optimization is primarily utilized to rank various alternatives and project types. However, the question arises: is it possible to use the multi-criteria optimization process for something more than that, in terms of determining the actual set of optimal criteria and creating optimal paths of their changes according to desired constraints? In this regard, it is necessary to find a connection between the output provided by multi-criteria optimization method itself and a hypothetical alternative that represents the current optimal alternative, referred to as a synthetic profile or transit optimum, which does not represent any initial alternative in the optimization matrix. Such an actual transit alternative is formed by the mutual influence of all factors in the decision matrix, but also depends on the multi-criteria optimization process itself. This requires the creation of a mathematical feedback loop between the optimization process and the redistribution of all alternatives according to the criteria, to create a new transit optimal set of criteria. As a representative method for multi-criteria optimization, the PSI (Preference Selection Index) method was selected because of its advantages in terms of its integrated procedure for calculating criteria weights and its objectivity in categorization. The proposed adaptive PSI framework introduces a synthetic profile that enables iterative feedback and two-stage optimization, transforming the classical static ranking into a dynamic adaptive process with a clear methodological advancement over existing MCDM techniques. The overall concept was tested on the optimization of thermal insulation thickness for walls under the conditions of Bosnia and Herzegovina.
- Open Access
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Green buil,p. 249-258
Sustainable building envelope renovation: integration of APV facade and timber energy systems (TES)
Improving the energy performance of buildings effectively reduces consumption and heating costs while elevating indoor comfort. This paper is a part of comprehensive research which examines energy poverty among residential building users-a prevalent issue in Bosnia and Herzegovina and neighboring countries. Furthermore, it analyzes various alternative solutions for upgrading the building envelope to demonstrate their feasibility. This paper investigates the role of energy efficiency in residential buildings and evaluates the potential of adaptive photovoltaic (APV) façade systems in deep energy renovation. Focusing on a multi-family residential building in Banja Luka, this study combines theoretical findings on energy performance with an advanced renovation scenario based on the Timber Energy System (TES) envelope and Solskin adaptive photovoltaic technology. A detailed analysis of this prefabricated alternative solution demonstrates that upgrading the building envelope substantially reduces heating demand, while the integrated active photovoltaic elements enable on-site electricity generation. Energy calculation results indicate that this systemic approach maintains specific energy need for heating at a low level of 21.93 kWh/m²a, elevating the building to energy class B in the study area. Furthermore, CO₂ emissions are drastically reduced from 216.75 tCO₂ to 74.85 tCO₂. Ultimately, the research confirms that comprehensive energy renovation not only enhances building performance but directly drives decarbonization, improves the residents' quality of life, and demonstrates how building envelopes can evolve from passive protective elements into active, energy-producing systems that mitigate energy poverty and support climate goals.
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Green buil,p. 249-258
Open AccessSustainable building envelope renovation: integration of APV facade and timber energy systems (TES)
Improving the energy performance of buildings effectively reduces consumption and heating costs while elevating indoor comfort. This paper is a part of comprehensive research which examines energy poverty among residential building users-a prevalent issue in Bosnia and Herzegovina and neighboring countries. Furthermore, it analyzes various alternative solutions for upgrading the building envelope to demonstrate their feasibility. This paper investigates the role of energy efficiency in residential buildings and evaluates the potential of adaptive photovoltaic (APV) façade systems in deep energy renovation. Focusing on a multi-family residential building in Banja Luka, this study combines theoretical findings on energy performance with an advanced renovation scenario based on the Timber Energy System (TES) envelope and Solskin adaptive photovoltaic technology. A detailed analysis of this prefabricated alternative solution demonstrates that upgrading the building envelope substantially reduces heating demand, while the integrated active photovoltaic elements enable on-site electricity generation. Energy calculation results indicate that this systemic approach maintains specific energy need for heating at a low level of 21.93 kWh/m²a, elevating the building to energy class B in the study area. Furthermore, CO₂ emissions are drastically reduced from 216.75 tCO₂ to 74.85 tCO₂. Ultimately, the research confirms that comprehensive energy renovation not only enhances building performance but directly drives decarbonization, improves the residents' quality of life, and demonstrates how building envelopes can evolve from passive protective elements into active, energy-producing systems that mitigate energy poverty and support climate goals.
- Open Access
- 1 January 2026
- Published by National Library of Serbia in Thermal Science
- No. 00,p. 64
Predicting the value of indoor CO₂ concentration in a university auditorium using a decision tree algorithm and a data mining method
The aim of this study is to predict the CO2 concentration levels based on data obtained in the auditorium of the new university building of the Faculty of Architecture, Civil Engineering and Geodesy and Faculty of Forestry (FACEG-FF) at the University of Banja Luka in correlation to the operation of the mechanical ventilation system. The data used for the analysis were collected from measurements and surveys on students’ subjective perception of indoor thermal and air quality. Data analysis and statistical processing were carried out using Statistical Product and Service Solutions (SPSS). The influence of measured physical parameters and the impact of user behaviour on CO2 concentration using the chi-square automatic interaction detection (CHAID) decision tree technique in a university auditorium was predicted. The dataset comprised 11 input variables (A1-A11), a continuous output variable representing CO₂ concentration (B1, ppm), and two predicted categorical outputs: B2, describing CO₂ concentration classes, and B3, indicating air quality satisfaction based on a 1000 ppm CO₂ threshold. Classification accuracy was between 89.2% and 97.5% for dependent variable B2 (class of indoor air quality) and 94.2% and 99.2% for dependent variable B3 (satisfactory - value below or above 1000 ppm CO₂). The findings indicate that maintaining CO₂ levels below 1000 ppm is crucial for ensuring satisfactory indoor air quality and thermal comfort among occupants.
- 1 January 2026
- Published by National Library of Serbia in Thermal Science
- No. 00,p. 64
Open AccessPredicting the value of indoor CO₂ concentration in a university auditorium using a decision tree algorithm and a data mining method
The aim of this study is to predict the CO2 concentration levels based on data obtained in the auditorium of the new university building of the Faculty of Architecture, Civil Engineering and Geodesy and Faculty of Forestry (FACEG-FF) at the University of Banja Luka in correlation to the operation of the mechanical ventilation system. The data used for the analysis were collected from measurements and surveys on students’ subjective perception of indoor thermal and air quality. Data analysis and statistical processing were carried out using Statistical Product and Service Solutions (SPSS). The influence of measured physical parameters and the impact of user behaviour on CO2 concentration using the chi-square automatic interaction detection (CHAID) decision tree technique in a university auditorium was predicted. The dataset comprised 11 input variables (A1-A11), a continuous output variable representing CO₂ concentration (B1, ppm), and two predicted categorical outputs: B2, describing CO₂ concentration classes, and B3, indicating air quality satisfaction based on a 1000 ppm CO₂ threshold. Classification accuracy was between 89.2% and 97.5% for dependent variable B2 (class of indoor air quality) and 94.2% and 99.2% for dependent variable B3 (satisfactory - value below or above 1000 ppm CO₂). The findings indicate that maintaining CO₂ levels below 1000 ppm is crucial for ensuring satisfactory indoor air quality and thermal comfort among occupants.
- Open Access
- 1 October 2025
- Published by Croatian Association of Civil Engineers in Journal of the Croatian Association of Civil Engineers
- Vol. 77 (09) , 833-844
Algorithmic energy retrofit model: Parametric optimization of indoor solar insolation
Over the past 50 years, summer temperatures in Banja Luka have risen by about 2°C, with peak values reaching 40.7°C in July. This trend has led to a significant increase in cooling demand in public buildings, particularly in educational facilities, which represent 31.59 % of all public buildings in Bosnia and Herzegovina. Solar irradiation affects the interior comfort through glare, reflection, and overheating. A case study was conducted on an educational facility in Banja Luka using open-source climate data, sky matrices, and wind condition data. Thermal comfort was assessed via the universal thermal climate index (UTCI) during peak occupancy hours (08:00–16:00) in summer using open-source data. Using an algorithmic model, vertical exterior shading elements were defined according to the intensity of solar irradiation. Simulations in Rhinoceros with Grasshopper, Ladybug, and Honeybee analysed indoor solar irradiation with and without shading in an office space. The results indicated that parametrically optimised shading reduced the highest interior temperature, dispersed solar irradiation more evenly, and enhanced thermal comfort by integrating passive cooling solutions.
- 1 October 2025
- Published by Croatian Association of Civil Engineers in Journal of the Croatian Association of Civil Engineers
- Vol. 77 (09) , 833-844
Open AccessAlgorithmic energy retrofit model: Parametric optimization of indoor solar insolation
Over the past 50 years, summer temperatures in Banja Luka have risen by about 2°C, with peak values reaching 40.7°C in July. This trend has led to a significant increase in cooling demand in public buildings, particularly in educational facilities, which represent 31.59 % of all public buildings in Bosnia and Herzegovina. Solar irradiation affects the interior comfort through glare, reflection, and overheating. A case study was conducted on an educational facility in Banja Luka using open-source climate data, sky matrices, and wind condition data. Thermal comfort was assessed via the universal thermal climate index (UTCI) during peak occupancy hours (08:00–16:00) in summer using open-source data. Using an algorithmic model, vertical exterior shading elements were defined according to the intensity of solar irradiation. Simulations in Rhinoceros with Grasshopper, Ladybug, and Honeybee analysed indoor solar irradiation with and without shading in an office space. The results indicated that parametrically optimised shading reduced the highest interior temperature, dispersed solar irradiation more evenly, and enhanced thermal comfort by integrating passive cooling solutions.
- Open Access
- 1 January 2025
- Published by Scientific-Professional Society for Disaster Risk Management
- p. 66-74
Analysis of Air Comfort of Students in Lecture Rooms in University Buildings from the 1960s and 2020s
- 1 January 2025
- Published by Scientific-Professional Society for Disaster Risk Management
- p. 66-74
Open AccessAnalysis of Air Comfort of Students in Lecture Rooms in University Buildings from the 1960s and 2020s
- Open Access
- 1 January 2025
- Published by National Library of Serbia in Thermal Science
- Vol. 29 (3 Part B) , 2141-2153
Optimization and experimental validation of a natural convection space heater using the Peltier elements
In this paper an experimental analysis was done aiming at studying the possibility of applying Peltier thermoelectric modules for building heating, more precisely, the optimization of a heat exchanger was performed. The concept of the system was designed to work without freon and harmful impact on the environment. The paper aims to develop a detailed mathematical optimization model of the existing heat exchanger for space heating by natural convection. Based on the optimal model, the new aluminum heat exchanger was created. The experiment was designed so that the Peltier elements were positioned on the heat exchangers and the input current and temperatures were measured. Firstly, experimental measurements were performed for the existing commercial heat exchanger, and, then, measurements were repeated with a new optimal heat exchanger under the same conditions. The COP of a space heating system using a Peltier thermoelectric generator has a low value if the system operates with natural convection and heat exchangers without optimal fin spacing. Optimizing the distance between the fins on the heat exchanger provides an increase in heat flow by convection almost up to ten times and the COP increases more than three times. This work has mathematically and experimentally confirmed that there is optimal fin spacing for finned heat exchangers with natural convection.
- 1 January 2025
- Published by National Library of Serbia in Thermal Science
- Vol. 29 (3 Part B) , 2141-2153
Open AccessOptimization and experimental validation of a natural convection space heater using the Peltier elements
In this paper an experimental analysis was done aiming at studying the possibility of applying Peltier thermoelectric modules for building heating, more precisely, the optimization of a heat exchanger was performed. The concept of the system was designed to work without freon and harmful impact on the environment. The paper aims to develop a detailed mathematical optimization model of the existing heat exchanger for space heating by natural convection. Based on the optimal model, the new aluminum heat exchanger was created. The experiment was designed so that the Peltier elements were positioned on the heat exchangers and the input current and temperatures were measured. Firstly, experimental measurements were performed for the existing commercial heat exchanger, and, then, measurements were repeated with a new optimal heat exchanger under the same conditions. The COP of a space heating system using a Peltier thermoelectric generator has a low value if the system operates with natural convection and heat exchangers without optimal fin spacing. Optimizing the distance between the fins on the heat exchanger provides an increase in heat flow by convection almost up to ten times and the COP increases more than three times. This work has mathematically and experimentally confirmed that there is optimal fin spacing for finned heat exchangers with natural convection.
- Open Access
- 12 June 2024
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy
- Vol. 16 (1) , 63-70
APPLICABILITY OF THE "TYPOLOGY OF RESIDENTIAL BUILDINGS IN BOSNIA AND HERZEGOVINA", AT A MUNICIPALITY OR CITY LEVEL, CASE STUDY - SINGLE-FAMILY HOUSES IN THE CITY DERVENTA
In order to make correct estimates of energy consumption for heating, reduction of energy consumption, and CO2 emissions by applying energy efficiency measures, it is necessary to know the structure and characteristics of the building stock. The Typology of residential buildings in Bosnia and Herzegovina identified the structure and characteristics of residential building stock through different periods at the level of Bosnia and Herzegovina. This paper analyses the differences between national and city or municipal typology. Conducted analysis for the City Derventa, shows that in the case of single-family houses, the application of national instead of local typology can result in certain deviations in the estimation of energy consumption, savings, and CO2 emissions.
- 12 June 2024
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy
- Vol. 16 (1) , 63-70
Open AccessAPPLICABILITY OF THE "TYPOLOGY OF RESIDENTIAL BUILDINGS IN BOSNIA AND HERZEGOVINA", AT A MUNICIPALITY OR CITY LEVEL, CASE STUDY - SINGLE-FAMILY HOUSES IN THE CITY DERVENTA
In order to make correct estimates of energy consumption for heating, reduction of energy consumption, and CO2 emissions by applying energy efficiency measures, it is necessary to know the structure and characteristics of the building stock. The Typology of residential buildings in Bosnia and Herzegovina identified the structure and characteristics of residential building stock through different periods at the level of Bosnia and Herzegovina. This paper analyses the differences between national and city or municipal typology. Conducted analysis for the City Derventa, shows that in the case of single-family houses, the application of national instead of local typology can result in certain deviations in the estimation of energy consumption, savings, and CO2 emissions.
- 10 April 2023
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 42 (4)
Resources efficient and cleaner production in the bentonite industry
The concept of Resource Efficient and Cleaner Production (RECP) focuses on a more cost‐effective production while effectively solve the problem of environmental pollution. This article presents the RECP methodology in the case of industrial production of the bentonite. Aspects of production and management to which it is possible to apply the specific methods, that is, RECP measures were analyzed. Mass and energy balance of the process as a whole were prepared and concrete measures were proposed. Applying the proposed measures increases the efficiency of the whole process. This is expressed as absolute and relative RECP Indicators. Relative indicators show an increase in energy productivity of 16.34%, an increase in materials and water productivity of 1.72%, and a decrease in the intensity of emissions of solid waste from 59.5%, carbon (CO2‐eq) of 7.78%, and wastewater of 1.69%. Expressed as absolute indicators, achieved benefits are: energy use reduction in the amount of 3,438,367.20 MJ/year, greenhouse gas emissions reduction in the amount of 167.04 t CO2 eq/year and reduction waste generation in the principal amount of 371.1 t/year.
- 10 April 2023
- Published by Wiley in Environmental Progress & Sustainable Energy
- Vol. 42 (4)
Resources efficient and cleaner production in the bentonite industry
The concept of Resource Efficient and Cleaner Production (RECP) focuses on a more cost‐effective production while effectively solve the problem of environmental pollution. This article presents the RECP methodology in the case of industrial production of the bentonite. Aspects of production and management to which it is possible to apply the specific methods, that is, RECP measures were analyzed. Mass and energy balance of the process as a whole were prepared and concrete measures were proposed. Applying the proposed measures increases the efficiency of the whole process. This is expressed as absolute and relative RECP Indicators. Relative indicators show an increase in energy productivity of 16.34%, an increase in materials and water productivity of 1.72%, and a decrease in the intensity of emissions of solid waste from 59.5%, carbon (CO2‐eq) of 7.78%, and wastewater of 1.69%. Expressed as absolute indicators, achieved benefits are: energy use reduction in the amount of 3,438,367.20 MJ/year, greenhouse gas emissions reduction in the amount of 167.04 t CO2 eq/year and reduction waste generation in the principal amount of 371.1 t/year.