Darija Gajić
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Darija Gajić has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Slobodan Peulić
Faculty of Architecture, Civil Engineering and Geodesy, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
6 shared publications - Milovan Kotur
Faculty of Mechanical Engineering, University of Banja Luka, Bosnia and Herzegovina
5 shared publications - Biljana Antunović
Faculty of Architecture, Civil Engineering and Geodesy, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
4 shared publications - Jelena Kljakić
Faculty of Architecture, Civil Engineering and Geodesy, University of Banja Luka, 78000 Banja Luka, Bosnia and Herzegovina
3 shared publications Biljana Antunović
University of Banja Luka
2 shared publicationsJelena Kljakić
University of Banja Luka
2 shared publications
Latest Publications
- Open Access
- 31 December 2026
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy in AГГ+
- Vol. 14 (1) , 25-40
Rethinking Wastewater: Value and the Role of Sustainable Technologies in NBS Circular Transitions
This paper critically examines the methodological boundaries of Life Cycle Assessment (LCA) within the context of sustainable design and infrastructure systems. By contrasting classical and ecological engineering logics, it reveals analytical blind spots in conventional LCA models, particularly the inability to recognize unrecovered resources, ecological co-benefits, and regenerative potentials. Drawing from case analyses and conceptual comparisons, the study questions the adequacy of cradle frameworks in addressing spatial, biological, and systemic complexities. In response, it proposes an expanded evaluation approach grounded in spatial-temporal dynamics, ecosystem integration, and syntropic principles. The findings support a necessary shift from impact-reduction metrics toward context-sensitive methodologies capable of supporting circular and regenerative design in nature-based solutions (NBS) architecture and infrastructure.
- 31 December 2026
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy in AГГ+
- Vol. 14 (1) , 25-40
Open AccessRethinking Wastewater: Value and the Role of Sustainable Technologies in NBS Circular Transitions
This paper critically examines the methodological boundaries of Life Cycle Assessment (LCA) within the context of sustainable design and infrastructure systems. By contrasting classical and ecological engineering logics, it reveals analytical blind spots in conventional LCA models, particularly the inability to recognize unrecovered resources, ecological co-benefits, and regenerative potentials. Drawing from case analyses and conceptual comparisons, the study questions the adequacy of cradle frameworks in addressing spatial, biological, and systemic complexities. In response, it proposes an expanded evaluation approach grounded in spatial-temporal dynamics, ecosystem integration, and syntropic principles. The findings support a necessary shift from impact-reduction metrics toward context-sensitive methodologies capable of supporting circular and regenerative design in nature-based solutions (NBS) architecture and infrastructure.
- Open Access
Analysis of Indoor Air Quality and Occupant Perception Under Different Mechanical Ventilation Operational Modes in a University Amphitheater
This paper presents an analysis of indoor air quality (IAQ) and occupant perception under different mechanical ventilation operational modes in a university amphitheater. Indoor environmental parameters, including air temperature, relative humidity, indoor air velocity, and CO2 concentration, were measured in accordance with ISO 7726. Ventilation performance and outdoor air supply requirements were evaluated according to BAS EN 16798-1 and ASHRAE 62.1, while thermal comfort interpretation followed ISO 7730. In parallel, a questionnaire survey was conducted to assess occupants’ perceptions of indoor air quality and its influence on concentration under different ventilation operating conditions. The results showed that CO2 concentrations occasionally exceeded 1000 ppm during extended occupancy periods but remained below 800 ppm for more than 60% of the measurement time. According to BAS EN 16798-1, the indoor environment was predominantly classified as Category I based on the indoor–outdoor CO2 concentration difference. Survey responses indicated that most students perceived the indoor air as clean, while 67% reported that IAQ influenced their ability to concentrate. The findings highlight the importance of occupancy-related ventilation control strategies in large educational spaces and demonstrate the potential for balancing indoor air quality and energy efficiency through appropriate ventilation system operation. The presented methodology may support future development of data-driven approaches for optimizing mechanical ventilation performance in university buildings.
Open AccessAnalysis of Indoor Air Quality and Occupant Perception Under Different Mechanical Ventilation Operational Modes in a University Amphitheater
This paper presents an analysis of indoor air quality (IAQ) and occupant perception under different mechanical ventilation operational modes in a university amphitheater. Indoor environmental parameters, including air temperature, relative humidity, indoor air velocity, and CO2 concentration, were measured in accordance with ISO 7726. Ventilation performance and outdoor air supply requirements were evaluated according to BAS EN 16798-1 and ASHRAE 62.1, while thermal comfort interpretation followed ISO 7730. In parallel, a questionnaire survey was conducted to assess occupants’ perceptions of indoor air quality and its influence on concentration under different ventilation operating conditions. The results showed that CO2 concentrations occasionally exceeded 1000 ppm during extended occupancy periods but remained below 800 ppm for more than 60% of the measurement time. According to BAS EN 16798-1, the indoor environment was predominantly classified as Category I based on the indoor–outdoor CO2 concentration difference. Survey responses indicated that most students perceived the indoor air as clean, while 67% reported that IAQ influenced their ability to concentrate. The findings highlight the importance of occupancy-related ventilation control strategies in large educational spaces and demonstrate the potential for balancing indoor air quality and energy efficiency through appropriate ventilation system operation. The presented methodology may support future development of data-driven approaches for optimizing mechanical ventilation performance in university buildings.
- Open Access
- 1 June 2026
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy
- Vol. 17 (1) , 215-228
FROM WASTE TO RESOURCE: BIOGAS PRODUCTION FROM BLACKWATER THROUGH DECENTRALIZED URBAN PLANNING MODELS
Blackwater, the wastewater stream with the highest sanitary and energy load, is increasingly seen as a resource within circular urban systems. This paper explores its valorization through anaerobic digestion and decentralized planning. Using Banja Luka as a case study, key energy, economic, and spatial thresholds for local treatment feasibility are defined. GIS-based analysis and a university campus pilot confirm that building aggregation enables functional clusters. Results show that demographically balanced, spatially compact zones hold the greatest potential. The cluster model proves optimal for integrating blackwater into sustainable urban systems. This reframes blackwater as a resource linking sanitation, energy, and planning.
- 1 June 2026
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy
- Vol. 17 (1) , 215-228
Open AccessFROM WASTE TO RESOURCE: BIOGAS PRODUCTION FROM BLACKWATER THROUGH DECENTRALIZED URBAN PLANNING MODELS
Blackwater, the wastewater stream with the highest sanitary and energy load, is increasingly seen as a resource within circular urban systems. This paper explores its valorization through anaerobic digestion and decentralized planning. Using Banja Luka as a case study, key energy, economic, and spatial thresholds for local treatment feasibility are defined. GIS-based analysis and a university campus pilot confirm that building aggregation enables functional clusters. Results show that demographically balanced, spatially compact zones hold the greatest potential. The cluster model proves optimal for integrating blackwater into sustainable urban systems. This reframes blackwater as a resource linking sanitation, energy, and planning.
- Open Access
- 1 June 2026
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy
- Vol. 17 (1) , 38-47
ASSESSMENT OF DAYLIGHT AVAILABILITY IN AN EDUCATIONAL BUILDING
This study analyses daylight availability in a faculty lecture classroom using illuminance measurements and a survey of students. The results of the measurements conducted in mid-February showed that the recommended horizontal illuminance level (300 lx) was achieved at 50% of the measurement points around midday (12:00 h and 14:00 h), while only 0–15% of the area met this requirement at 8:00 h and 16:00 h. The minimum illuminance level (100 lx) was satisfied at all measurement points around midday but decreased to 25–45% in the early morning and late afternoon. Survey results indicated that 76.7% of students reported the need for artificial lighting during the winter period. Since natural daylight is sufficient during certain periods of the day, optimisation of the lighting system and the integration of controlled sensors for supplementary lighting are recommended.
- 1 June 2026
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy
- Vol. 17 (1) , 38-47
Open AccessASSESSMENT OF DAYLIGHT AVAILABILITY IN AN EDUCATIONAL BUILDING
This study analyses daylight availability in a faculty lecture classroom using illuminance measurements and a survey of students. The results of the measurements conducted in mid-February showed that the recommended horizontal illuminance level (300 lx) was achieved at 50% of the measurement points around midday (12:00 h and 14:00 h), while only 0–15% of the area met this requirement at 8:00 h and 16:00 h. The minimum illuminance level (100 lx) was satisfied at all measurement points around midday but decreased to 25–45% in the early morning and late afternoon. Survey results indicated that 76.7% of students reported the need for artificial lighting during the winter period. Since natural daylight is sufficient during certain periods of the day, optimisation of the lighting system and the integration of controlled sensors for supplementary lighting are recommended.
- Open Access
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Green buil,p. 249-258
Sustainable building envelope renovation: integration of APV facade and timber energy systems (TES)
Improving the energy performance of buildings effectively reduces consumption and heating costs while elevating indoor comfort. This paper is a part of comprehensive research which examines energy poverty among residential building users-a prevalent issue in Bosnia and Herzegovina and neighboring countries. Furthermore, it analyzes various alternative solutions for upgrading the building envelope to demonstrate their feasibility. This paper investigates the role of energy efficiency in residential buildings and evaluates the potential of adaptive photovoltaic (APV) façade systems in deep energy renovation. Focusing on a multi-family residential building in Banja Luka, this study combines theoretical findings on energy performance with an advanced renovation scenario based on the Timber Energy System (TES) envelope and Solskin adaptive photovoltaic technology. A detailed analysis of this prefabricated alternative solution demonstrates that upgrading the building envelope substantially reduces heating demand, while the integrated active photovoltaic elements enable on-site electricity generation. Energy calculation results indicate that this systemic approach maintains specific energy need for heating at a low level of 21.93 kWh/m²a, elevating the building to energy class B in the study area. Furthermore, CO₂ emissions are drastically reduced from 216.75 tCO₂ to 74.85 tCO₂. Ultimately, the research confirms that comprehensive energy renovation not only enhances building performance but directly drives decarbonization, improves the residents' quality of life, and demonstrates how building envelopes can evolve from passive protective elements into active, energy-producing systems that mitigate energy poverty and support climate goals.
- 1 January 2026
- Published by Centre for Evaluation in Education and Science (CEON/CEES)
- No. Green buil,p. 249-258
Open AccessSustainable building envelope renovation: integration of APV facade and timber energy systems (TES)
Improving the energy performance of buildings effectively reduces consumption and heating costs while elevating indoor comfort. This paper is a part of comprehensive research which examines energy poverty among residential building users-a prevalent issue in Bosnia and Herzegovina and neighboring countries. Furthermore, it analyzes various alternative solutions for upgrading the building envelope to demonstrate their feasibility. This paper investigates the role of energy efficiency in residential buildings and evaluates the potential of adaptive photovoltaic (APV) façade systems in deep energy renovation. Focusing on a multi-family residential building in Banja Luka, this study combines theoretical findings on energy performance with an advanced renovation scenario based on the Timber Energy System (TES) envelope and Solskin adaptive photovoltaic technology. A detailed analysis of this prefabricated alternative solution demonstrates that upgrading the building envelope substantially reduces heating demand, while the integrated active photovoltaic elements enable on-site electricity generation. Energy calculation results indicate that this systemic approach maintains specific energy need for heating at a low level of 21.93 kWh/m²a, elevating the building to energy class B in the study area. Furthermore, CO₂ emissions are drastically reduced from 216.75 tCO₂ to 74.85 tCO₂. Ultimately, the research confirms that comprehensive energy renovation not only enhances building performance but directly drives decarbonization, improves the residents' quality of life, and demonstrates how building envelopes can evolve from passive protective elements into active, energy-producing systems that mitigate energy poverty and support climate goals.
- Open Access
- 1 January 2026
- Published by National Library of Serbia in Thermal Science
- No. 00,p. 64
Predicting the value of indoor CO₂ concentration in a university auditorium using a decision tree algorithm and a data mining method
The aim of this study is to predict the CO2 concentration levels based on data obtained in the auditorium of the new university building of the Faculty of Architecture, Civil Engineering and Geodesy and Faculty of Forestry (FACEG-FF) at the University of Banja Luka in correlation to the operation of the mechanical ventilation system. The data used for the analysis were collected from measurements and surveys on students’ subjective perception of indoor thermal and air quality. Data analysis and statistical processing were carried out using Statistical Product and Service Solutions (SPSS). The influence of measured physical parameters and the impact of user behaviour on CO2 concentration using the chi-square automatic interaction detection (CHAID) decision tree technique in a university auditorium was predicted. The dataset comprised 11 input variables (A1-A11), a continuous output variable representing CO₂ concentration (B1, ppm), and two predicted categorical outputs: B2, describing CO₂ concentration classes, and B3, indicating air quality satisfaction based on a 1000 ppm CO₂ threshold. Classification accuracy was between 89.2% and 97.5% for dependent variable B2 (class of indoor air quality) and 94.2% and 99.2% for dependent variable B3 (satisfactory - value below or above 1000 ppm CO₂). The findings indicate that maintaining CO₂ levels below 1000 ppm is crucial for ensuring satisfactory indoor air quality and thermal comfort among occupants.
- 1 January 2026
- Published by National Library of Serbia in Thermal Science
- No. 00,p. 64
Open AccessPredicting the value of indoor CO₂ concentration in a university auditorium using a decision tree algorithm and a data mining method
The aim of this study is to predict the CO2 concentration levels based on data obtained in the auditorium of the new university building of the Faculty of Architecture, Civil Engineering and Geodesy and Faculty of Forestry (FACEG-FF) at the University of Banja Luka in correlation to the operation of the mechanical ventilation system. The data used for the analysis were collected from measurements and surveys on students’ subjective perception of indoor thermal and air quality. Data analysis and statistical processing were carried out using Statistical Product and Service Solutions (SPSS). The influence of measured physical parameters and the impact of user behaviour on CO2 concentration using the chi-square automatic interaction detection (CHAID) decision tree technique in a university auditorium was predicted. The dataset comprised 11 input variables (A1-A11), a continuous output variable representing CO₂ concentration (B1, ppm), and two predicted categorical outputs: B2, describing CO₂ concentration classes, and B3, indicating air quality satisfaction based on a 1000 ppm CO₂ threshold. Classification accuracy was between 89.2% and 97.5% for dependent variable B2 (class of indoor air quality) and 94.2% and 99.2% for dependent variable B3 (satisfactory - value below or above 1000 ppm CO₂). The findings indicate that maintaining CO₂ levels below 1000 ppm is crucial for ensuring satisfactory indoor air quality and thermal comfort among occupants.
- Open Access
- 31 December 2025
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy in AГГ+
- Vol. 13 (1) , 133-147
Assessing the Energy Renovation Impact on Public Building Performance: A Case Study of The Faculty of Natural Sciences and Mathematics in Banja Luka
Buildings in Bosnia and Herzegovina are among the largest energy consumers, and deep energy renovation is a key pathway to reducing consumption and costs. This paper presents a case study of an educational building in Banja Luka, renovated in 2016 through envelope improvements and optimization of the heating system. Energy bills from 2013–2015 and 2022 were analyzed, and an energy audit evaluated the corresponding conditions (design values), which were then compared with actual consumption based on the energy bills. Total energy savings amounted to 94.18 kWh/m², or 74.96%, while economic savings reached 28.56%. The renovation also replaced coal as the heating medium with biomass, improving energy efficiency and supporting decarbonization goals. This study contributes by providing data on final energy use for heating in educational and cultural buildings, thereby supporting future improvements to national energy efficiency regulations.
- 31 December 2025
- Published by University of Banja Luka, Faculty of Architecture, Civil Engineering and Geodesy in AГГ+
- Vol. 13 (1) , 133-147
Open AccessAssessing the Energy Renovation Impact on Public Building Performance: A Case Study of The Faculty of Natural Sciences and Mathematics in Banja Luka
Buildings in Bosnia and Herzegovina are among the largest energy consumers, and deep energy renovation is a key pathway to reducing consumption and costs. This paper presents a case study of an educational building in Banja Luka, renovated in 2016 through envelope improvements and optimization of the heating system. Energy bills from 2013–2015 and 2022 were analyzed, and an energy audit evaluated the corresponding conditions (design values), which were then compared with actual consumption based on the energy bills. Total energy savings amounted to 94.18 kWh/m², or 74.96%, while economic savings reached 28.56%. The renovation also replaced coal as the heating medium with biomass, improving energy efficiency and supporting decarbonization goals. This study contributes by providing data on final energy use for heating in educational and cultural buildings, thereby supporting future improvements to national energy efficiency regulations.
- Open Access
- 1 January 2025
- Published by Scientific-Professional Society for Disaster Risk Management
- p. 66-74
Analysis of Air Comfort of Students in Lecture Rooms in University Buildings from the 1960s and 2020s
- 1 January 2025
- Published by Scientific-Professional Society for Disaster Risk Management
- p. 66-74
Open AccessAnalysis of Air Comfort of Students in Lecture Rooms in University Buildings from the 1960s and 2020s
- Open Access
- 1 January 2025
- Published by National Library of Serbia in Thermal Science
- Vol. 29 (3 Part B) , 2185-2197
Reliability of experimental methods to determine heat transmission coefficient of the existing building façade wall
Experimental methods are often only possible solution to determining heat transmission coefficient (U-value) of elements in existing buildings. These methods can be of great importance in developing countries which are tackling energy poverty by conducting deep energy retrofit of the existing building stock, such as in case of Bosnia and Herzegovina. The ISO 9869-1 standard recognizes heat-flow-meter (HFM) methodology as enough precise to give reliable results. However, this methodology predicts strict criteria under which measuring can be done, what is sometimes not possible. Other method standardized with ISO 9869-2 includes quantitative infra-red thermography (QIRT) which is much suitable to conduct in-situ, yet, for its non-contact properties it is not as reliable as previous one. This paper aims to show process of implementation of these methods and statistically compare them to theoretical method made according to ISO 6946. Compared to theoretical heat transmission coefficient of Utheor.=1.366 W/m2K, results showed deviations ranging from S = ?4.17% to S = +1.61% for HFM method, with mean value of Umean =1.39 W/m2K, and S = 5.38% for QIRT method, with mean value of Umean = 1.29 W/m2K. In this paper, a comparative overview is made to show importance and applicability of each method, their prerequisites and reliability in real context.
- 1 January 2025
- Published by National Library of Serbia in Thermal Science
- Vol. 29 (3 Part B) , 2185-2197
Open AccessReliability of experimental methods to determine heat transmission coefficient of the existing building façade wall
Experimental methods are often only possible solution to determining heat transmission coefficient (U-value) of elements in existing buildings. These methods can be of great importance in developing countries which are tackling energy poverty by conducting deep energy retrofit of the existing building stock, such as in case of Bosnia and Herzegovina. The ISO 9869-1 standard recognizes heat-flow-meter (HFM) methodology as enough precise to give reliable results. However, this methodology predicts strict criteria under which measuring can be done, what is sometimes not possible. Other method standardized with ISO 9869-2 includes quantitative infra-red thermography (QIRT) which is much suitable to conduct in-situ, yet, for its non-contact properties it is not as reliable as previous one. This paper aims to show process of implementation of these methods and statistically compare them to theoretical method made according to ISO 6946. Compared to theoretical heat transmission coefficient of Utheor.=1.366 W/m2K, results showed deviations ranging from S = ?4.17% to S = +1.61% for HFM method, with mean value of Umean =1.39 W/m2K, and S = 5.38% for QIRT method, with mean value of Umean = 1.29 W/m2K. In this paper, a comparative overview is made to show importance and applicability of each method, their prerequisites and reliability in real context.