MTMatthias Tummers

Matthias Tummers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Matthias Tummers has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Cosserat Rod Modeling of Continuum Robots : Application to Concentric Agonist-Antagonist Robots

    by Matthias Tummers

    Modélisation de Robots Continus par la Théorie de Cosserat : Application aux Robots Concentriques Agonistes-Antagonistes: La robotique médicale est, depuis une quarantaine d'années, un domaine en plein essor associant les progrès en robotique et soins de santé au bénéfice du patient. Aujourd'hui, la plupart des robots cliniques sont des robots rigides, caractérisés par une rigidité mécanique et des degrés de liberté limités. Cependant, ces dernières années ont connu une tendance croissante au développement de robots conçus pour interagir avec le corps humain de manière plus souple et offrir une plus grande dextérité aux cliniciens. En outre, afin de réduire davantage le caractère invasif de la chirurgie, des voies empruntant les orifices naturels sont envisagées en priorité. Cela a conduit à l'avènement des robots continus dans le domaine de la robotique médicale. Les robots continus sont composés de matériaux élastiques, de sorte que leur structure se déforme continûment lorsqu'ils sont actionnés, ce qui leur confère des degrés de liberté infinis. Ces degrés de liberté donnent aux robots continus la capacité de se conformer aux voies de l'anatomie humaine. De plus, ils peuvent souvent être réduits à de très petites tailles (0,5 mm de diamètre), ce qui élargit encore le champ des applications possibles. Si les robots continus offrent de nouveaux avantages, ce type de robots présente également de nouveaux défis pour la communauté. Premièrement, d'un point de vue structurel, de tels robots peuvent subir un certain nombre de phénomènes physiques qui limitent leurs performances. Deuxièmement, pour la mise en place de robots continus, il faut disposer de modèles précis qui relient les variables d'actionnement à la forme complète du robot. Dans ce deuxième défi, l'élasticité des matériaux constitutifs doit être prise en compte, ainsi que les interactions avec l'environnement. Pour répondre à ces défis, la recherche en robotique continue développe activement de nouvelles structures et nouveaux modèles de robots. Dans cette thèse, la conception et la modélisation d'une nouvelle structure de robot continu, à savoir les robots concentriques agonistes-antagonistes (RCAA), ont été étudiées. Les RCAA sont identifiés comme des robots prometteurs et leur potentiel pour les applications médicales est analysé. Afin de développer pleinement les RCAA et de contrôler leur forme ou la position de leur extrémité, un modèle mécanique précis était manquant. De tels modèles sont évidemment utilisés à des fins de commande, mais aussi pour l'optimisation de conception, la planification de trajectoire, la perception et l'analyse de leur stabilité, manipulabilité, etc. Plus les modèles de robots continus sont précis, plus ils peuvent être exploités avantageusement pour ces différentes tâches. Cette thèse propose un tel modèle mécanique basée sur la théorie de Cosserat. Le modèle est dérivé par une approche lagrangienne, qui est apparue plus récemment dans la communauté que l'approche newtonienne initialement développée. Alors que l'approche newtonienne isole les composants du robot et considère leurs interactions (lois de Newton), l'approche lagrangienne considère le système dans son ensemble. Elle dérive les modèles de robot par une application canonique du principe des travaux virtuels. En considérant le système dans sa globalité, cette approche peut fournir une compréhension plus complète du comportement des robots continus. Dans cette thèse, les similitudes et différences entre les deux approches sont examinées plus en détail à travers, entre-autres, une étude comparative dans le cas des robots continus actionnés par câbles. C'est cette analyse approfondie qui a permis de dériver un modèle Cosserat pour les RCAA. Enfin, le modèle développé est validé expérimentalement, utilisant différents prototypes de RCAA imprimés en 3D, en espace libre et avec des forces externes appliquées à l'extrémité du robot. Les résultats sont concluants, avec une erreur moyenne à l'extrémité du robot de 1,47 % de la longueur du robot, pour tous les cas expérimentaux.


  • Development and Control of a Macro–Micro Multi-Arm Robotic System for Open Spina Bifida Treatment

    by Xiaohang Zhang, Di Wu, Matthias Tummers, Yuyu Cai, Yao Zhang, Tom Vandebroek, Gianni Borghesan, Jan Deprest, Emmanuel Vander Poorten

    Open spina bifida (OSB), a congenital anomaly caused by incomplete spinal column closure, leads to progressive nerve damage. While multi-port minimally invasive procedures are being optimized clinically, single-port access (SPA) surgery presents a promising, less invasive alternative. Beyond reducing scarring, SPA may also decrease the risk of iatrogenic preterm premature rupture of membranes and enhance maternal recovery, as suggested by outcomes in other minimally invasive interventions. However, technical challenges persist in SPA implementations, particularly in instrument miniaturization and control precision. To facilitate this approach, a macro-micro multi-arm robotic system is under development. The system features an 11-mm-diameter insertion port to deploy four instrument arms. The arm design incorporates a hybrid backbone structure. A macro proximal section of concentric tubes provides stable deployment, while a micro distal flexible segment enables the dexterous manipulation. This paper presents dedicated modeling and control strategies to address actuator and transmission nonlinearities arising from stringent miniaturization requirements. A hybrid framework combining joint-level feedback with deep-learning-based feedforward compensation mitigates limitations imposed by pneumatic artificial muscles and tendon transmissions. The system is validated through trajectory-following experiments, each conducted over 10 trials. Preliminary results show an average root-mean-squared error of 0.28 mm, an average maximum absolute error of 0.85 mm, and an average standard deviation of 0.18 mm across both trajectories. These results demonstrate consistent sub-millimeter precision, satisfying the requirement for OSB repair. The feasibility of the system was then verified through a phantom study.


  • Open Access

    A large, paired dataset of robotic and handheld lumbar spine ultrasound with ground-truth CT benchmarking

    by Nicola A. Cavalcanti, Ruixuan Li, Laura Arango, Ayoob Davoodi, Kaat Van Assche, Yunke Ao, Aidana Massalimova, Mehrdad Salehi, Lukas Zingg, Tobias Götschi, et al.

    Musculoskeletal disorders present significant socio-economic challenges globally, requiring innovative diagnostic and therapeutic approaches. Current intraoperative imaging techniques, including computed tomography (CT) and radiography, involve high radiation exposure and limited soft tissue visualization. Ultrasound (US) offers a non-invasive, real-time alternative but is underutilized intraoperatively, as it is highly observer-dependent. US enhanced by artificial intelligence shows high potential for observer-independent surgical guidance, decision support, and robot-assisted applications in orthopedics. Given the limited availability of high-quality, in vivo ultrasound data, we introduce a comprehensive dataset from a collection of handheld 2D US (HUS) and robot-assisted US (RUS) lumbar spine imaging in 63 healthy volunteers. This dataset includes demographic data, HUS and RUS imaging with synchronized 3D positioning data of the US probe, corresponding CT data, and CT-reconstructed 3D models of the lumbar vertebrae L1 to L5, establishing a robust baseline for machine learning algorithms. This extensive collection is the first anatomy dataset for the lumbar spine that includes paired CT, HUS, and RUS imaging, supporting advancements in intraoperative imaging and robot-assisted surgery.


  • Robotic Path Re-Planning for US Reconstruction of the Spine

    by Kaat Van Assche, Ruixuan Li, Ayoob Davoodi, Matthias Tummers, Mouloud Ourak, Gianni Borghesan, Nicola Cavalcanti, Philipp Fürnstahl, Emmanuel Vander Poorten

    Robotic ultrasound (US) scanning of the spine is becoming an increasingly viable radiation-free alternative to CT scans and fluoroscopy. However, due to the complex shape of the vertebra, three-dimensional (3D) US reconstructions generated from two-dimensional (2D) US scans often lack important anatomic information, such as the spinous process. This paper investigates scanning strategies that reorient the probe during US scanning to improve surface coverage of 3D US reconstructions. A two-scan procedure with a path re-planning algorithm is presented. The proposed algorithm uses information from a first exploratory scan to generate an improved imaging trajectory whereby the US probe is near-perpendicular to the targeted bone surface. The results show a 30.4%, 42.3%, and 75.0% improvement in surface coverage on a synthetic phantom, cadaver, and human volunteers, respectively, achieving up to 56% surface coverage on human volunteers. These results emphasise the value of exploiting information about the underlying anatomy to optimise the scanning trajectory. The increased surface coverage of the 3D US reconstructions will provide higher quality radiationfree visualisation, extending the role of US as a complementary imaging modality for safe and effective diagnosis and spine interventions.


  • Continuum concentric push–pull robots: A Cosserat rod model

    by Matthias Tummers, Frédéric Boyer, Vincent Lebastard, Alexis Offermann, Jocelyne Troccaz, Benoît Rosa, M. Taha Chikhaoui

    Various approaches and structures emerged recently to design continuum robots. One of the most promising designs regards a new concept of continuum concentric push–pull robots (CPPRs) that have the characteristic of combining several key advantages of tendon actuated, multi-backbone, and concentric tube ones (direct curvature actuation, small outer/inner diameter ratio, free lumen, etc.). Geometrically-exact models of such recently introduced robots are yet to be developed to gain leverage of their full potential. This article extends beyond usual definitions of Cosserat rod theory in order to take into account this new type of continuum robots, constituted by sliding rods, in a shape of tubes whose cross-sections are neither uniform nor symmetrical along their entire length. The introduced model is capable of considering versatile design options, external loads, 3D deformations, an arbitrary number of tubes and profiles of the centroid lines, as well as a new actuation method consisting of an input rotation. Numerical simulations and experiments on CPPR prototypes validate our model.


  • Ultrasound-Based Robot-Assisted Drilling for Minimally Invasive Pedicle Screw Placement

    by Ruixuan Li, Ayoob Davoodi, Maikel Timmermans, Kaat Van Assche, Or Cun Taylan, Lennart Scheys, Matthias Tummers, Gianni Borghesan, Emmanuel Vander Poorten

    Minimally invasive pedicle screw placement (MIPSP) is a widely used treatment for spine diseases. When coupled with intraoperative navigation modalities, robots may help improve surgical outcomes and reduce complications. With such a system, the application of pedicle screws has been expanded from needle insertion to the spine surgery. This paper investigates the possibility and feasibility of robot-assisted MIPSP based on ultrasound (US) guidance. The proposed system is non-radiative and fiducial-free, using purely image information to close the registration loop. Then the system automatically positions the drill tip to a planned screw trajectory and executes the drilling operation. Experiments were conducted on both ex-vivo lamb and human cadaver spines. An entry point accuracy of 2.39±1.41 mm, and orientation accuracy of 2.82±1.85∘ was found for 24 drilled trajectories on three lamb spines. On the ex-vivo human spine, the position error averaged 3.08±2.43 mm at the entry point and 4.05±2.62 mm at the stop point across 16 drilling instances. Moreover, a 87.5% success rate was reported by using Gertzbein-Robbins grade. The experimental results demonstrate the potential for offering a radiation-free alternative. Although restricted to cadaver trials, this work encourages further exploration of this technology to assist surgeons in maximizing performance in clinical practice.


  • Cosserat Rod Modeling of Continuum Robots from Newtonian and Lagrangian Perspectives

    by Matthias Tummers, Vincent Lebastard, Frédéric Boyer, Jocelyne Troccaz, Benoît Rosa, M. Taha Chikhaoui

    Cosserat rod theory proved efficient modeling performances in robotics, especially in the context of continuum robots, in the past decade. The implementation of such theory is far from being unique and straightforward. We consider the illustrative example of multisegment, general routing tendon actuated continuum robots in their nominal static operating regime. This article details two main approaches based on Cosserat rod modeling, namely, the Newtonian and Lagrangian approaches. We provide a walk-through guide regarding theoretical derivations and numerical implementation of both approaches, together with a proof of equivalence. This comparative study is supplemented with novel contributions and extensions of each approach and in-depth discussion of their performances and applicability, as well as highlighting their special features.