MTMarcelo Azeredo Terra

Marcelo Azeredo Terra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Marcelo Azeredo Terra has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ultrasound assessment of diaphragmatic function during weaning and after extubation in preterm newborns: brief report

    by Marcos Giovanni Santos Carvalho, Juliana Nasu Tomiyama, Marcelo Azeredo Terra, Fernanda Cordoba Lanza

    To describe and assess diaphragmatic function by ultrasound during the weaning and post-extubation phases in preterm newborns. This cross-sectional study included intubated preterm newborns eligible for extubation. Inspiratory diaphragmatic thickness (IDT), expiratory diaphragmatic thickness (EDT), diaphragmatic thickening fraction (DTF), and diaphragmatic excursion (DE) were evaluated at three time points: T1—during invasive mechanical ventilation (IMV); T2—during the spontaneous breathing trial (SBT); and T3—during nasal intermittent positive pressure ventilation (NIPPV). Friedman test and Wilcoxon signed-rank post hoc test were used for comparisons ( p < 0.05). Fifty preterm newborns were evaluated. Forty-five (mean gestational age 30.9 ± 2.2 weeks; mean weight 1377.5 ± 432 g) received IMV for 4 ± 3 days and were successfully extubated (extubation failure rate 10%). Due to the small number of failures ( n = 5), only descriptive analyses were performed. In successfully extubated newborns, IDT and DE increased at T2 and T3 compared to T1 ( p < 0.05), with IDT highest at T2. No significant changes were observed in EDT or DTF, which remained consistently elevated. Conclusion : In preterm newborns successfully extubated, diaphragmatic thickness and excursion increased during the SBT and remained elevated after extubation. These findings may support the use of diaphragmatic ultrasound to guide extubation readiness and monitor post-extubation adaptation in preterm infants. What is Known: • Extubation decisions in preterm infants rely mainly on clinical judgment .• Diaphragmatic ultrasound is used to assess diaphragmatic function in various neonatal clinical situations . What is New: • This study provides descriptive data on diaphragmatic function throughout the entire weaning and post-extubation process in preterm newborns undergoing a spontaneous breathing trial (SBT) .• In successfully extubated preterm newborns, diaphragmatic thickness and excursion increased during the SBT and remained elevated after extubation, suggesting that the SBT may increase respiratory effort without reliably indicating extubation readiness in this population .

  • Diaphragmatic ultrasonography: reference values and reliability for thickness, thickening fraction, and excursion in neonates

    by Marcos Giovanni Santos Carvalho, Juliana Nasu Tomiyama, Marcelo Azeredo Terra, Fernanda Cordoba Lanza

    To establish reference values and assess the intra- and inter-rater reliability of inspiratory diaphragmatic thickness (IDT), expiratory diaphragmatic thickness (EDT), diaphragmatic thickening fraction (DTF), and diaphragmatic excursion (DE) using ultrasound, including the lower (LLN) and upper (ULN) limits of normality in neonates. This cross-sectional study included healthy neonates from a public hospital (July 2022–December 2023). IDT, EDT, DTF, and DE were measured by PT 1 (an experienced ultrasound physiotherapist). Reliability was assessed by having PT 1 and PT 2 (experts ultrasound physiotherapists) independently evaluate the exams twice using ImageJ software. Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to assess intra- and inter-rater reliability. One hundred neonates were assessed [39 (38–40) weeks, 3168 ± 475 g, 49 (47.5–50) cm]. Reference values were EDT: 2.17 ± 0.59 mm, LLN: 2.05 mm and ULN: 2.29 mm; IDT: 1.71 ± 0.48 mm, LLN: 1.62 mm and ULN: 1.80 mm; DTF: 28.02 ± 9.88%, LLN: 26.08% and ULN: 29.96%; DE: 2.47 ± 0.72 mm, LLN: 2.33 mm and ULN: 2.61 mm. No significant differences were observed between the assessments of PT 1 and PT 2 (p > 0.05), intra- and inter-rater reliability were ICC ≥ 0.98 (0.97–1.00) (p < 0.001) and ICC ≥ 0.91 (0.85–0.99) (p < 0.001), respectively. Conclusion: The established values support interpreting neonatal diaphragmatic function and detecting changes in contractility and motion range, with high intra- and inter-rater reliability for EDT, IDT, DTF, and DE. What is Known: • Diaphragmatic ultrasound is used to assess diaphragm function in various clinical contexts; however, its reliability and reference values for neonates are limited. What is New: • Performing diaphragmatic ultrasound in neonates requires specific precautions to obtain accurate and reliable measurements. • The established normal, lower, and upper limits for diaphragmatic thickness and excursion support the functional assessment of the diaphragm in neonates by aiding in the detection of changes in contractility and movement, providing valuable reference values for clinical decision-making.


  • Open Access

    Development of an application for teaching pulmonary ultrasound in an emergency

    by Erik Macedo, Paulo Goberlânio de Barros Silva, Edgar Marçal, Juliana Paiva Marques Lima Rolim, Marcelo Azeredo Terra

    Introduction: The use of ultrasound protocols has revolutionized care in emergency medicine and can help in the diagnosis of respiratory failure in emergency care; therefore, medical training for the use of these protocols has become important. It has also been demonstrated that medical smartphone apps have positive results in daily practice, in addition to being a potentially valuable educational tool. Objective: Thus, the objective was to develop an emergency pulmonary ultrasound application. The “BLUE SIM” is a cell phone application that simulates clinical cases using the “Bedside Lung Ultrasound in Emergency” protocol, which can help students and health professionals regarding the use of pulmonary ultrasound in the care of acute respiratory failure. The hypothesis is that the “BLUE SIM” will be a usable and acceptable application among users. Method: After the development, the application was evaluated with a group of 36 volunteers, which included 18 physical therapists and 18 other professionals consisting of physicians, nurses and medical students. The usability and usefulness of a mobile application for the iOS system was analyzed, using the System Utility Score (SUS) usability scale and the Technology Acceptance Model (TAM) as references. The obtained data were tabulated and analyzed using Fisher’s exact test or Mann-Whitney test. Result: When applying the SUS questionnaire (usability), the application obtained a score of 76.8%. A score of 75% was obtained exclusively among physical therapists, with no statistical difference between the general group of all emergency professionals and the group of physical therapists only (p=0.239). According to the usefulness perception analysis, 93.9% of the emergency professionals had a positive response, while a score of 88.9% was obtained among physical therapists (p=0.04). Conclusion: It was concluded that the developed application was classified as useful in learning the diagnosis of respiratory failure among health professionals; however, they considered that training is necessary for its use.


  • Open Access

    Desenvolvimento de um aplicativo para ensino de ultrassonografia pulmonar em emergência

    by Erik Macedo, Paulo Goberlânio de Barros Silva, Edgar Marçal, Juliana Paiva Marques Lima Rolim, Marcelo Azeredo Terra

    Resumo: Introdução: A utilização de protocolos de ultrassonografia revolucionou o atendimento na medicina de emergência e pode auxiliar no diagnóstico de insuficiência respiratória no pronto atendimento. Assim, torna-se importante o treinamento médico para a utilização desses protocolos. Já foi demonstrado também que os aplicativos de smartphone médico têm resultados positivos na prática diária, além de serem uma ferramenta educacional potencialmente valiosa. Objetivo: Dessa forma, o objetivo deste estudo foi desenvolver um aplicativo em ultrassonografia pulmonar de emergência. O BLUE SIM é um aplicativo de celular que simula atendimentos de casos clínicos utilizando o protocolo Bedside Lung Ultrasound in Emergency, o qual pode auxiliar alunos e profissionais da área da saúde a usar a ultrassonografia pulmonar no atendimento da insuficiência respiratória aguda. A hipótese é que o BLUE SIM será um aplicativo usável e aceitável entre os usuários. Método: Após desenvolvido, avaliou-se o aplicativo com 36 voluntários: 18 fisioterapeutas, um médico, sete enfermeiros e dez acadêmicos de Medicina. Analisaram-se a usabilidade e a utilidade de uma aplicação móvel para o sistema iOS, utilizando como referências a escala de usabilidade System Utility Score (SUS) e o modelo de aceitação Technology Acceptance Model (TAM). Os dados obtidos foram tabulados e analisados pelo teste exato de Fisher ou Mann-Whitney. Resultado: Pela aplicação do questionário SUS (usabilidade), o aplicativo obteve um escore de 76,8%. Exclusivamente entre os fisioterapeutas, obteve-se um escore de 75%, não havendo diferença estatística entre o grupo geral de todos os profissionais emergencistas e o grupo somente de fisioterapeutas (p = 0,239). Segundo a análise de percepção de utilidade, 93,9% dos profissionais emergencistas responderam positivamente, enquanto, entre os fisioterapeutas, obteve-se um escore de 88,9% (p = 0,04). Conclusão: O aplicativo desenvolvido foi classificado de utilidade na aprendizagem do diagnóstico de insuficiência respiratória entre os profissionais, contudo eles consideraram que é necessário um treinamento para o uso da ferramenta.