Sarnab Bhattacharya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sarnab Bhattacharya has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Nanshu Lu
Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, TX, USA
4 shared publications - Animesh Tandon
Department of Heart, Vascular, and Thoracic, Division of Cardiology and Cardiovascular Medicine, Children’s Institute, Cleveland Clinic Children’s, Cleveland, USA
2 shared publications - Jieting Wang
Department of Kinesiology and Health Education
2 shared publications - Matija Jankovic
University of Texas at Austin, USA
2 shared publications - Omer T. Inan
Georgia Institute of Technology, Atlanta, Georgia, USA
2 shared publications - Philip Tan
University of Texas at Austin, USA
2 shared publications
Latest Publications
- Open Access
- 14 July 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 122 (29)
Wireless arm-worn bioimpedance sensor for continuous assessment of whole-body hydration
Assessment of whole-body hydration (WBH) is crucial for health management and disease diagnosis. Traditional methods are invasive or require bulky equipment, making them impractical for mobile, continuous sensing. We present a wearable bioimpedance sensor with strategic electrode placement across the arm for noninvasive, continuous, and mobile WBH monitoring. Although whole-body bioimpedance is a proven method for indicating WBH, the effectiveness of local bioimpedance measurement has been unclear. Our finite element analysis demonstrated that with an optimized cross-arm sensing configuration, a strong linear relationship exists between arm bioimpedance and muscle electrical resistivity, confirming the utility of arm bioimpedance for assessing WBH given the well-established relationship between muscle electrical resistivity and body water. Our IRB-approved diuretic-induced dehydration study demonstrated a strong linear correlation between the increase of arm bioimpedance and the decrease in body weight due to water loss, with a Pearson correlation coefficient of 0.956 ± 0.033 among eight participants. Arm and whole-body demonstrated strong alignment, suggesting that arm bioimpedance measurements can reflect not only changes in WBH but also potentially absolute WBH status when compared against established population reference data. In a 24-h free-living experiment, the wireless, dry electrode-based, arm-conformable bioimpedance sensor continuously tracked dehydration and rehydration despite motions associated with daily activities. These results suggest that properly measured arm bioimpedance can serve as a surrogate for WBH, offering a reliable and accessible solution. The potential uses of this wearable technology range from improving personal wellness to enhancing professional sports and occupational safety.
- 14 July 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences of the United States of America
- Vol. 122 (29)
Open AccessWireless arm-worn bioimpedance sensor for continuous assessment of whole-body hydration
Assessment of whole-body hydration (WBH) is crucial for health management and disease diagnosis. Traditional methods are invasive or require bulky equipment, making them impractical for mobile, continuous sensing. We present a wearable bioimpedance sensor with strategic electrode placement across the arm for noninvasive, continuous, and mobile WBH monitoring. Although whole-body bioimpedance is a proven method for indicating WBH, the effectiveness of local bioimpedance measurement has been unclear. Our finite element analysis demonstrated that with an optimized cross-arm sensing configuration, a strong linear relationship exists between arm bioimpedance and muscle electrical resistivity, confirming the utility of arm bioimpedance for assessing WBH given the well-established relationship between muscle electrical resistivity and body water. Our IRB-approved diuretic-induced dehydration study demonstrated a strong linear correlation between the increase of arm bioimpedance and the decrease in body weight due to water loss, with a Pearson correlation coefficient of 0.956 ± 0.033 among eight participants. Arm and whole-body demonstrated strong alignment, suggesting that arm bioimpedance measurements can reflect not only changes in WBH but also potentially absolute WBH status when compared against established population reference data. In a 24-h free-living experiment, the wireless, dry electrode-based, arm-conformable bioimpedance sensor continuously tracked dehydration and rehydration despite motions associated with daily activities. These results suggest that properly measured arm bioimpedance can serve as a surrogate for WBH, offering a reliable and accessible solution. The potential uses of this wearable technology range from improving personal wellness to enhancing professional sports and occupational safety.
- 10 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (1) , 413-424
Cardiac Time Intervals Under Motion Using Bimodal Chest E-Tattoos and Multistage Processing
Goal: We present a thin, soft, and chest conformable bimodal sensor, known as the chest e-tattoo, coupled with an advanced signal processing framework to accurately identify various cardiac events, and thereby extract cardiac time intervals even during body motion. Methods: We built a wireless electronic tattoo that features synchronous electrocardiography (ECG) and seismocardiography (SCG). The SCG measures chest vibrations due to heartbeat, providing information on cardiovascular health that is complementary to the ECG. However, the efficacy of the SCG is compromised by motion-induced artifacts. The slim and stretchy design of the e-tattoo allows it to be strategically placed near the xiphoid process, facilitating high-quality monitoring of the ECG and SCG for increased signal quality. Nine participants were measured during walking and cycling. We propose a multistage signal processing framework, integrating an adaptive Normalized Least Mean Squares (NLMS) filter, ensemble averaging, and Empirical Mode Decomposition (EMD), together named the FAD framework, to accurately extract cardiac time intervals (CTIs)
- 10 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 72 (1) , 413-424
Cardiac Time Intervals Under Motion Using Bimodal Chest E-Tattoos and Multistage Processing
Goal: We present a thin, soft, and chest conformable bimodal sensor, known as the chest e-tattoo, coupled with an advanced signal processing framework to accurately identify various cardiac events, and thereby extract cardiac time intervals even during body motion. Methods: We built a wireless electronic tattoo that features synchronous electrocardiography (ECG) and seismocardiography (SCG). The SCG measures chest vibrations due to heartbeat, providing information on cardiovascular health that is complementary to the ECG. However, the efficacy of the SCG is compromised by motion-induced artifacts. The slim and stretchy design of the e-tattoo allows it to be strategically placed near the xiphoid process, facilitating high-quality monitoring of the ECG and SCG for increased signal quality. Nine participants were measured during walking and cycling. We propose a multistage signal processing framework, integrating an adaptive Normalized Least Mean Squares (NLMS) filter, ensemble averaging, and Empirical Mode Decomposition (EMD), together named the FAD framework, to accurately extract cardiac time intervals (CTIs)
- Open Access
- 25 September 2023
- Published by Springer Nature in Current Treatment Options in Pediatrics
- Vol. 9 (4) , 247-259
Non-invasive Cardiac Output Monitoring in Congenital Heart Disease
Purpose of review: Cardiac output (CO) is a fundamental physiological parameter that measures the volume of blood that is pumped by the heart per unit of time, and helps define how oxygen is delivered to the tissues of the human body. In this paper, we discuss current methods of continuous CO monitoring while defining low CO syndrome (LCOS) and how analytical tools may help improve CO management in the subpopulation of patients with congenital heart disease (CHD). Recent findings: Non-invasive methods of measuring CO have become increasingly available in recent years. Advantages of non-invasive over invasive techniques include decreased risk of procedural complications, decreased exposure to sedative and/or anesthetic agents, and increased patient comfort. Pediatric patient populations are particularly sensitive to the risks and complications of invasive techniques given the relative size of current technologies to pediatric vascular and cardiac dimensions. Summary: Novel device technologies, combined with emerging analytical techniques, may help improve measurement of CO in children and those with CHD, and allow earlier detection of LCOS.
- 25 September 2023
- Published by Springer Nature in Current Treatment Options in Pediatrics
- Vol. 9 (4) , 247-259
Open AccessNon-invasive Cardiac Output Monitoring in Congenital Heart Disease
Purpose of review: Cardiac output (CO) is a fundamental physiological parameter that measures the volume of blood that is pumped by the heart per unit of time, and helps define how oxygen is delivered to the tissues of the human body. In this paper, we discuss current methods of continuous CO monitoring while defining low CO syndrome (LCOS) and how analytical tools may help improve CO management in the subpopulation of patients with congenital heart disease (CHD). Recent findings: Non-invasive methods of measuring CO have become increasingly available in recent years. Advantages of non-invasive over invasive techniques include decreased risk of procedural complications, decreased exposure to sedative and/or anesthetic agents, and increased patient comfort. Pediatric patient populations are particularly sensitive to the risks and complications of invasive techniques given the relative size of current technologies to pediatric vascular and cardiac dimensions. Summary: Novel device technologies, combined with emerging analytical techniques, may help improve measurement of CO in children and those with CHD, and allow earlier detection of LCOS.
- Open Access
- 18 April 2023
- Published by Wiley in Advanced Electronic Materials
- Vol. 9 (9)
A Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals
Cardiovascular diseases are the leading cause of death globally. Noninvasive, accurate, and continuous cardiovascular monitoring can enable the preemptive detection of heart diseases and timely intervention to prevent serious cardiac complications. However, unobtrusive, ambulatory, and comprehensive cardiac monitoring is still a challenge as conventional electronics are rigid, heavy, or consume too much power for long‐term measurement. This work presents a thin (200 µm), stretchable (20%), lightweight (2.5 g), wireless, and low‐power (<3 mW) cardiac monitoring device that conforms to the human chest like a temporary tattoo sticker, correspondingly known as an e‐tattoo. This chest e‐tattoo features dual‐mode electro‐mechanical sensing—bio‐electric cardiac signals via electrocardiography and mechanical cardiac rhythm via seismocardiography. A unique peripheral synchronization strategy between the two sensors enables the measurement of systolic time intervals like the pre‐ejection period and the left ventricular ejection time with high accuracy (error = −0.44 ± 8.74 ms) while consuming very low power. The e‐tattoo is validated against clinically approved gold‐standard instruments on five human subjects. The good wearability and low power consumption of this e‐tattoo permit 24‐h continuous ambulatory monitoring.
- 18 April 2023
- Published by Wiley in Advanced Electronic Materials
- Vol. 9 (9)
Open AccessA Chest‐Conformable, Wireless Electro‐Mechanical E‐Tattoo for Measuring Multiple Cardiac Time Intervals
Cardiovascular diseases are the leading cause of death globally. Noninvasive, accurate, and continuous cardiovascular monitoring can enable the preemptive detection of heart diseases and timely intervention to prevent serious cardiac complications. However, unobtrusive, ambulatory, and comprehensive cardiac monitoring is still a challenge as conventional electronics are rigid, heavy, or consume too much power for long‐term measurement. This work presents a thin (200 µm), stretchable (20%), lightweight (2.5 g), wireless, and low‐power (<3 mW) cardiac monitoring device that conforms to the human chest like a temporary tattoo sticker, correspondingly known as an e‐tattoo. This chest e‐tattoo features dual‐mode electro‐mechanical sensing—bio‐electric cardiac signals via electrocardiography and mechanical cardiac rhythm via seismocardiography. A unique peripheral synchronization strategy between the two sensors enables the measurement of systolic time intervals like the pre‐ejection period and the left ventricular ejection time with high accuracy (error = −0.44 ± 8.74 ms) while consuming very low power. The e‐tattoo is validated against clinically approved gold‐standard instruments on five human subjects. The good wearability and low power consumption of this e‐tattoo permit 24‐h continuous ambulatory monitoring.